基于网络分区的大电网故障限流器的优化布点方法
Optimal Distribution of Fault Current Limiter in Power Grids Based on Network Partition
DOI: 10.12677/SG.2015.51004, PDF, HTML, XML, 下载: 2,752  浏览: 6,708 
作者: 孙建波, 李大虎:国网湖北省电力公司,湖北 武汉;周蓓蓓, 程潜善, 方华亮:武汉大学电气工程学院,湖北 武汉
关键词: 网络分区故障限流器优化布点Network Partition Fault Current Limiter Optimal Distribution
摘要: 故障限流器(FCL)可以快速地限制短路电流,保证系统安全稳定运行。本文提出一种故障限流器优化布点的新方法。首先将大电网分区等效处理,通过进行短路计算,得出每条支路的短路电流分布系数,根据短路电流分布系数的大小,从中选取安装FCL的位置,然后结合FCL的经济性确定安装的最佳位置。最后,通过某地区实际电网的仿真验证了所述方法的有效性,实现了FCL的优化布点,限制了超标短路电流水平。
Abstract: The short-circuit current can be quickly limited by the fault current limiter (FCL) to ensure the system safe and stable. A new method for fault current limiter distribution optimization is pre-sented. Large-scale power grids are first equivalently treated to each partition and through short-circuit calculation, the distribution coefficients of short-circuit current of each branch are got. According to the value of distribution coefficients of short-circuit current, the location of the FCL can be selected. Then the optimum positions are determined combined with the economy of FCL. Finally, the validity of the method is proved through the simulation of a real regional power grid, optimal distribution of FCL is achieved and the excessive short-circuit current is limited.
文章引用:孙建波, 李大虎, 周蓓蓓, 程潜善, 方华亮. 基于网络分区的大电网故障限流器的优化布点方法[J]. 智能电网, 2015, 5(1): 27-34. http://dx.doi.org/10.12677/SG.2015.51004

参考文献

[1] 叶幼君, 鲍爱霞, 程云志 (2006) 浙江500 kV电网短路电流的控制. 华东电力, 3, 10-15.
[2] 王华昕, 习贺勋, 汤广福, 等 (2007) 谐振型故障限流器阻抗特性仿真和参数优化. 电力系统自动化, 5, 61-64.
[3] 费万民, 张艳莉, 吕征宇 (2006) 基于IGBT的新型固态桥式短路故障限流器. 电力系统自动化, 7, 60-64.
[4] 徐竹娴, 江道灼, 林日磊, 等 (2008) 三相不接地系统桥式固态限流器的故障诊断方法. 电力系统自动化, 12, 68-72.
[5] Cronin, J.C. (1972) Fault current limiter using superconductive element. United States Patent, 3703664[p]v.21.
[6] 应林志, 王健全, 陈迅, 等 (2000) 基于模糊控制遗传算法的输电系统最优化规划. 电力系统自动化, 2, 51-55.
[7] Hongesombut, K., Mitaniy, Y. and Tsuji, K. (2003) Optimal location assignment and design of superconducting fault current limiters applied to loop power systems. IEEE Transactions on Applied Superconductivity, 13, 1828-1931.
[8] Teng, J.H. and Lu, C.N. (2010) Optimum fault current limiter placement with search space reduction technique. IET Generation Transmission & Distribution, 4, 485-494.
[9] 胡文旺, 卫志龙, 孙国强, 等 (2012) 基于灵敏度法的超导故障限流器的优化配置. 电力系统自动化, 22, 62-67.
[10] Nagata, M., Tanaka, K. and Taniguchi, H. (2001) FCL location selection in large scale power system. IEEE Transactions on Applied Super-conductivity, 11, 2489-2494.
[11] 钱家骊, 刘卫兵, 关勇刚 (2004) 非超导型故障电流限制器的技术经济分析. 电网技术, 9, 42-43, 61.