基于传感器阵列和独立分量分析的远场涡流缺陷信号盲分离技术研究
Blind Separation of Remote Field Eddy Current Defect Signal from Magnetic Perturbation Based on Independent Component Analysis
DOI: 10.12677/EAA.2015.42002, PDF, HTML, XML, 下载: 2,802  浏览: 7,708  国家自然科学基金支持
作者: 徐小杰, 裴文林, 张浩杰:空军工程大学信息与导航学院, 陕西 西安
关键词: 无损检测远场涡流独立分量分析缺陷磁导率不均匀Nondestructive Testing Remote Field Eddy Current Independent Component Analysis Defect Magnetic Perturbation
摘要: 针对远场涡流检测中管道磁导率不均匀严重影响缺陷信号检测的问题,本文提出一种新的基于独立分量分析的远场涡流缺陷信号盲分离技术。首先利用有限元仿真对独立分量分析在缺陷分离中的适用性进行了详细分析,证实了磁导率不均匀和缺陷信号满足独立分量分析的应用前提。提出了基于实部和虚部信号的独立分量分析缺陷分离方法,并进行了仿真和实验验证。结果表明,基于独立分量分析技术能够有效的从磁导率不均匀区域分离和识别出缺陷。
Abstract: According to influence of magnetic perturbation in remote field eddy current defect detection, a novel blind separation technique based on independent component analysis was proposed. Firstly, finite element method was adopted to declare the applicability of independent component analysis in remote field eddy current. Secondly, a new method based on real part and imaginary part rather than amplitude and phase signal was proposed, and simulation and experiment was implemented to verify it. At last, a conclusion could be deduced from simulation and experiment results as followed: the influence of magnetic perturbation could be eliminated significantly by using independent component analysis.
文章引用:徐小杰, 裴文林, 张浩杰. 基于传感器阵列和独立分量分析的远场涡流缺陷信号盲分离技术研究[J]. 电磁分析与应用, 2015, 4(2): 7-17. http://dx.doi.org/10.12677/EAA.2015.42002

参考文献

[1] 李家伟, 陈积懋 (2012) 无损检测手册(第二版). 机械工业出版社, 北京, 415-416.
[2] 徐小杰 (2007) 铁磁性管道中轴向裂纹的远场涡流检测关键技术研究. 博士学位论文, 国防科学技术大学, 长沙.
[3] Kobayashi, N., Ueno, S., Nagai, S., et al. (2011) Remote field eddy current testing for steam generator inspection of fast reactor. Nuclear Engineering and Design, 241, 4643-4648.
[4] Atherton, D.L. (1995) Remote field eddy current inspection. IEEE Transactions on Magnetics, 31, 4142-4147.
[5] Zhang, S.P., Yao, H.X., Sun, X., et al. (2014) Action recognition based on overcomplete independent components analysis. Information Sciences, 28, 635-647.
[6] Khalil, M. and Sarkar, A. (2014) Independent component analysis to enhance performances of karhunen-loeve expansions for non-gaussian stochastic processes: Application to uncertain systems. Journal of Sound and Vibration, 21, 5600- 5613.
[7] Xie, S.J., Chen, Z.M., Takagi, T., et al. (2012) Development of a very fast simulator for pulsed eddy current testing signals of local wall thinning. NDT & E International, 51, 45-50.
[8] Chen, Z.M., Rebican, M. and Miya, K. (2005) Three dimensional simulation of remote field ECT using the Ar method and a new formula for signal calculation. Research in NDE, 16, 35-53.
[9] 吴德会, 黄松岭, 赵伟, 等 (2009) 油气管道裂纹远场涡流检测的仿真分析. 中国机械工程, 12, 1450-1454.