基于ADS1294的表面肌电信号检测系统设计
Design of Surface Electromyography Measurement System Based on ADS1294
DOI: 10.12677/CSA.2015.57032, PDF, HTML, XML, 下载: 2,768  浏览: 6,779 
作者: 徐羽晨, 史井雄:中国地质大学(武汉)机械与电子信息学院,湖北 武汉
关键词: 表面肌电信号ADS1294LabVIEWSurface Electromyography ADS1294 LabVIEW
摘要: 针对表面肌电信号微弱、易受干扰的特点,设计了一种基于ADS1294的表面肌电信号检测系统。系统采用了模拟前端ADS1294电路对表面肌电信号进行滤波、调理和采集,设计了MSP430F169主控制器电路将采集的肌电信号数据传输给上位机,并在LabVIEW环境下,开发了肌电信号检测系统上位机应用程序。该应用程序功能包括信号显示、数字滤波、波形记录及存储回放。实验结果表明,此系统能有效采集及显示表面肌电信号。
Abstract: According to the weakness and vulnerable of the surface electromyography, a surface electro-myography measurement system based on ADS1294 is designed in this paper. The system uses the ADS1294 circuit to condition and measure the surface electromyography. And a MSP430F169 control circuit is adapted to transfer the measured signal to the upper computer. In the LabVIEW environment, a surface electromyography detection application is designed and developed. The application functions include surface electromyography waveform display, digital filtering, wave-form recording and playback. The validity has been verified by lots of experiment.
文章引用:徐羽晨, 史井雄. 基于ADS1294的表面肌电信号检测系统设计[J]. 计算机科学与应用, 2015, 5(7): 247-254. http://dx.doi.org/10.12677/CSA.2015.57032

参考文献

[1] 高韧杰 (2013) 智能仿生手臂的表面肌电信号采集与动作仿真系统设计. 吉林大学, 吉林.
[2] 朱仕勇 (2013) 手持式肌电信号采集系统设计与应用研究. 武汉理工大学, 武汉.
[3] 赖玥, 肖纯贤, 马超, 等 (2013) 基于S3C2440和ADS1294的心电信号采集和处理系统. 南开大学学报(自然科学版), 46, 93-96.
[4] 吴晓维, 田联房, 莫鸿强, 等 (2013) 表面膈肌肌电的测量系统的设计与实现. 计算机测量与控制, 21, 82-84.
[5] 滕燕, 王士允, 尹振全, 李小宁 (2013) 表面肌电信号采集与处理系统研究. 机床与液压, 41, 4-7.
[6] 席旭刚, 左静, 张启忠, 罗志增 (2014) 多通道表面肌电信号降噪与去混迭研究. 传感技术学报, 27, 293-298.
[7] 娄智, 邓浩, 陈香, 等 (2014) 基于自适应阈值处理的表面肌电信号小波去噪研究. 生物医学工程学杂志, 31, 723-728.
[8] 卜峰, 李传江, 陈佳佳, 等 (2014) 基于ARM的肌电假肢控制器. 上海大学学报(自然科学版), 20, 442-449.
[9] 路敦强, 王为, 陈永鹏 (2015) 基于ADS1298的表面肌电采集系统设计. 天津师范大学学报(自然科学版), 35, 34-37.
[10] http://www.ti.com/product/ADS1294