输电线路复合绝缘子的电气及机械特性
Electrical and Mechanical Performance of Transmission Line Composite Insulator
摘要:
以挂网运行线路110 kV、220 kV复合绝缘子为研究对象,对其电气、机械性能进行了试验检测;在此基础上对复合绝缘子的运行状态进行了有效评估。结果表明,运行多年的复合绝缘子,其电气和机械综合性能仍基本满足线路运行要求,老化特征与其运行时间之间存在一定的相关性。试验研究结果可为复合绝缘子的运行和维护工作提供参考。
Abstract: Taking 110 kV and 220 kV operation line composite insulators as research objects, the electrical performance and mechanical performance were investigated in this paper. On this basis, the con-dition of running composite insulator was effectively evaluated. The results show that the electrical and mechanical properties of the composite insulators running for many years are still eligible for the basic requirements of operation line. The aging characteristic of composite insulators has some correlation with the running time. The test results can provide a reference for the operation and maintenance of composite insulators.
参考文献
[1]
|
张福增, 宋磊, 屠幼萍. 500 kV复合绝缘子运行特性分析[J]. 高电压技术, 2012(4): 2536-2541.
|
[2]
|
印华, 吴高林, 王勇. 重庆电网500 kV交流复合绝缘子运行特性的试验研究[J]. 高压电器, 2010(9): 22-25.
|
[3]
|
王少华, 叶自强, 罗盛. 500 kV复合绝缘子断裂机理及检测方法[J]. 中国电力, 2011(8): 19-21.
|
[4]
|
中国国家标准化管理委员会. GB/T 19519-2004标称电压高于1000 V的交流架空线路用复合绝缘子——定义, 试验方法及验收准则[S]. 北京: 中国标准出版社, 2004.
|
[5]
|
中华人民共和国国家发展和改革委员会. DL/T 864-2004标称电压高于1000 V交流架空线路用复合绝缘子使用导则[S]. 北京: 中国电力出版社, 2004.
|