基于MEMS技术悬臂梁式脉搏传感器制作与特性研究
Fabrication and Characteristics Research of the Cantilever Beam Pulse Sensor Based on MEMS Technology
DOI: 10.12677/JSTA.2016.43012, PDF, HTML, XML, 下载: 2,450  浏览: 7,655  国家科技经费支持
作者: 李森, 陈静, 李丹丹, 赵晓锋*:黑龙江省普通高等学校电子工程重点实验室,黑龙江大学,黑龙江 哈尔滨
关键词: 脉搏传感器悬臂梁MEMS技术惠斯通电桥Pulse Sensor Cantilever Beam MEMS Technology Wheatstone Bridge
摘要: 本文给出悬臂梁式脉搏传感器,该结构由硅悬臂梁和悬臂梁根部四个压敏电阻构成的惠斯通电桥结构组成。基于压阻效应,当悬臂梁顶端受到脉搏力F作用时,悬臂梁发生弹性形变,引起四个扩散压敏电阻阻值发生变化,桥路输出电压变化,实现对脉搏力F的测量。基于MEMS技术在<100>晶向单晶硅衬底实现传感器芯片制作和封装,当工作电压VDD = 5.0 V时,外力F = 100 mg作用下悬臂梁输出电压为111 mV,传感器灵敏度为0.54 mV/mg,准确度为5.90% F.S.。实验结果表明,该悬臂梁结构可实现脉搏力F测量且灵敏度较高。
Abstract: This paper presents the cantilever beam pulse sensor, and the structure consists of the silicon cantilever beam and Wheatstone bridge that contains cantilever beam roots four piezoresistors. Based on the piezoresistive effect, when the cantilever top was touched by pulse force, the elastic deformation of the cantilever beam occurred, which induced the change of the piezoresistive value and the bridge output voltage, and finally the measurement of the pulse was realized. Based on the sensor chip fabrication and packaging on the <100> orientations silicon substrate, when supply voltage VDD = 5.0 V, the cantilever beam output voltage is 111 mV under the 100 mg external force, the sensor sensitivity is 0.54 mV/mg, and the accuracy rating is 5.90% F.S. Experimental results show that the cantilever beam structure enables accomplish pulse measurement and possesses high sensitivity.
文章引用:李森, 陈静, 李丹丹, 赵晓锋. 基于MEMS技术悬臂梁式脉搏传感器制作与特性研究[J]. 传感器技术与应用, 2016, 4(3): 101-108. http://dx.doi.org/10.12677/JSTA.2016.43012

参考文献

[1] 燕海峡, 王忆琴, 李福凤. 中医脉象传感器的研究进展[J]. 上海中医药大学学报, 2005, 19(1): 62-64.
[2] 张珣, 周杰. 光电脉搏传感器的设计与改进[J]. 中国医疗器械杂志, 2009, 33(5): 344-346.
[3] Hlenschi, C., Corodeanu, S. and Chiriac, H. (2013) Magnetoelastic Sensors for the Detections of Pulse Waves. IEEE Transactions on Magnetics, 49, 117-119.
http://dx.doi.org/10.1109/TMAG.2012.2219855
[4] An, Y.-J., Kim, B.-H., et al. (2016) Flexible Non-Constrained RF Wrist Pulse Detection Sensor Based on Array Resonnators. IEEE Transactions on Biomedical Circuits and Systems, 10, 300-308.
http://dx.doi.org/10.1109/TBCAS.2015.2406776
[5] Joshi, A.B., Kalange, A.E., Bodas, D. and Gangal, S.A. (2010) Simula-tions of Piezoelectric Pressure Sensor for Radical Artery Pulse Measurement. Materials Science and Engineering B, 168, 250-253.
http://dx.doi.org/10.1016/j.mseb.2010.01.012
[6] Wu, J.M., Lee, C.C. and Lin, Y.H. (2015) High Sensitivity Wrist-Worn Pulse Active Sensor Made from Tellurium Dioxide. Nano Energy, 14, 102-110.
http://dx.doi.org/10.1016/j.nanoen.2015.02.009
[7] Wang, D.M., Zhang, D. and Lu, G.M. (2015) An Optimal Pulse System Design by Multichannel Sensor Fusion. IEEE Journal of Biomedical and Health Informatics, 20, 450-459.
http://dx.doi.org/10.1109/JBHI.2015.2392132
[8] 赵晓锋, 温殿忠. 在EPW中采用(100)硅制作微悬臂梁凸角及工艺研究[J]. 黑龙江大学自然科学学报, 2005, 22(5): 697-700.
[9] Zhao, X.F., Yu, Y., Li, D.D. and Wen, D.Z. (2015) Design Fabrication and Characterization of a High-Sensitivity Pressure Sensor Based on Nano-Polysilicon Thin Film Transistor. AIP Advances, 5, Article ID: 127216.
http://dx.doi.org/10.1063/1.4938517
[10] Zhao, X.F., Wen, D.Z. and Li, G. (2012) Fabrication and Characteristics of the nc-Si/c-Si Heterojunction MOSFETs Pressure Sensor. Sensors, 12, 6369-6379.
http://dx.doi.org/10.3390/s120506369
[11] 赵晓锋, 温殿忠. 纳米多晶硅薄膜压力传感器制作及特性研究[J]. 半导体学报, 2008, 29(10): 2038-2042.
[12] 杨磊, 于虹, 赵阳. 硅悬臂梁的制造及压阻特性研究[J]. 电子器件, 2009, 32(6): 1015-1018.
[13] 温殿忠, 赵晓锋. 传感器原理与应用[M]. 北京: 科学出版社, 2013: 5-14.
[14] 华成英, 童诗白. 模拟电子技术基础[M]. 北京: 高等教育出版社, 2006: 330-333.
[15] 孙丽晶. 基于ICC AVR和Proteus软件平台的AVR单片机设计开发流程[J]. 吉林师范大学学报(自然科学版), 2010, 31(1): 103-105.
[16] 王波. 基于AVR单片机的石灰乳配制及添加智能控制系统的研究[D]: [硕士学位论文]. 昆明: 昆明理工大学选矿自动化及计算机应用, 2011: 1-7.