NST  >> Vol. 5 No. 4 (October 2017)

    离子交换处理放射性废水的实验研究
    Experimental Study on Treating the Radioactive Waste Water by Ion Exchange

  • 全文下载: PDF(1308KB) HTML   XML   PP.211-215   DOI: 10.12677/NST.2017.54027  
  • 下载量: 195  浏览量: 595   科研立项经费支持

作者:  

杨彬,马若霞,许国静,徐杨华:国家电投集团远达环保工程有限公司重庆科技分公司,重庆

关键词:
放射性废水离子交换去污因子Radioactive Liquid Waste Ion Exchange Decontamination Factor

摘要:

本文在前期调研和实验基础上,设计了一套离子交换中试实验装置(1级沸石 + 4级树脂),并试验了该装置对模拟非放废水(含锶、铯、钴)的处理效果,实验结果表明,该离子交换中试实验装置对锶、铯、钴有较好的去除效果,去污因子达到104

This paper designed a set of ion exchange experiment pilot device (1 zeolite + 4 resin) base on the research and experiment. The device’s ability to treat simulate non-radioactive wastewater (in-cluding strontium, cesium and cobalt) is verified, and the experimental results show that decon-tamination factor of ion exchange device was 104 to process strontium, cesium and cobalt.

文章引用:
杨彬, 马若霞, 许国静, 徐杨华. 离子交换处理放射性废水的实验研究[J]. 核科学与技术, 2017, 5(4): 211-215. https://doi.org/10.12677/NST.2017.54027

参考文献

[1] 国家环境保护部. GB6249-2011——核动力厂环境辐射防护规定[M]. 北京: 中国环境科学出版社, 2011.
[2] 柳丹, 刘杰安. 离子交换树脂处理核电厂废液模拟试验研究[J]. 给水排水, 2012(增刊): 248-251.
[3] 李福志, 孙大卫. 内陆AP1000核电项目低放废液排放的主要污染物及其处理技术[J]. 原子能科学技术, 2012, 46(S1): 137-141.
[4] 方祥洪, 马若霞, 杨彬. 放射性废水的离子交换树脂处理性能研究[J]. 广东化工, 2016, 43(24): 122.
[5] 方祥洪, 杨彬, 马若霞. 放射性废水的无机离子吸附处理性能研究[J]. 山东化工, 2017, 46(1): 129-130.