负荷模型对天津电网短路电流的影响
Impact of Load Model on Short-Circuit Current in Tianjin Power Grid
DOI: 10.12677/SG.2016.63014, PDF, HTML, XML,  被引量 下载: 1,953  浏览: 3,748 
作者: 邱丽萍*, 唐晓骏:中国电力科学研究院,北京;于光耀:国网天津市电力公司电力科学研究院,天津;李振斌, 黄志刚:国网天津市电力公司,天津
关键词: 负荷模型短路电流天津电网特高压Load Model Short-Circuit Current Tianjin Power Grid UHV
摘要: 特高压接入天津电网后,天津电网将形成1000/500 kV电磁环网,导致电网短路电流水平提高,甚至导致部分母线短路电流超标。负荷模型是影响电网短路电流水平的重要因素,本文针对各静态负荷及感应电动机负荷对天津电网短路电流的影响进行了分析,并从机理上给出了解释。
Abstract: With the building of UHV substation, Tianjin power grid will form 1000/500 kV electromagnetic ring network, which will lead to the improvement of the short-circuit current, and even make some short-circuit current of bus exceed the switch breaking capacity. Load model is an important factor affecting the level of short-circuit current of power grid, in this paper the influence of the static load and induction motor load on the short-circuit current in Tianjin power grid is analyzed, and the mechanism is given.
文章引用:邱丽萍, 唐晓骏, 于光耀, 李振斌, 黄志刚. 负荷模型对天津电网短路电流的影响[J]. 智能电网, 2016, 6(3): 129-137. http://dx.doi.org/10.12677/SG.2016.63014

参考文献

[1] 邱丽萍, 金小明, 林勇, 等. 负荷模型对电力系统仿真计算的影响[J]. 电力系统及其自动化学报, 2014, 26(11): 87-90.
[2] IEEE Task Force on Load Representation for Dynamic Performance (1995) Standard Load Models for Power Flow and Dynamic Performance Simulation. IEEE Transactions on Power Systems, 10, 1302-1313.
http://dx.doi.org/10.1109/59.466523
[3] 鞠平, 马大强. 电力系统负荷建模[M]. 北京: 水利电力出版社, 1995.
[4] 汤涌, 张红斌, 侯俊贤, 等. 考虑配电网络的综合负荷模型. 电网技术, 2007, 31(5): 34-38.
[5] 西安交通大学. 电力系统计算[M]. 北京: 水利电力出版社, 1978.
[6] EL-Hawary, M.E. and Dias, L.G. (1987) Incor-poration of Load Models in Load-Flow Studies: Form of Model Effects. IEE Proceedings C Generation, Transmission and Distribution, 134, 27-30.
http://dx.doi.org/10.1049/ip-c.1987.0004
[7] Ebrahim, V., El-Din, H.M.Z. and Price, W.W. (1988) Dynamic Load Modeling in Large Scale Stability Studies. IEEE Transactions on Power Systems, 3, 1039-1045.
http://dx.doi.org/10.1109/59.14559