减小来自阴极保护装置杂散电流干扰的实验探究
Experiments to Explore the Decrease of Stray Current Interference from Cathode Protection
DOI: 10.12677/MP.2015.53009, PDF, HTML, XML,  被引量 下载: 2,782  浏览: 8,546  国家自然科学基金支持
作者: 汪 洋, 张亚萍, 韩秀虹, 韩 雪, 句东旭, 于濂清:中国石油大学(华东)理学院,山东 青岛;李 焰:中国石油大学(华东)机电工程学院,山东 青岛
关键词: 杂散电流牺牲阳极涂层保护管地电位Stray Current Sacrificial Anode Coating Protection Electrode Potential
摘要: 采用实验室模拟的方法,研究在管线交叉处使用牺牲阳极和涂层保护两种措施的实验效果,将两种措施减小或消除来自阴极保护设施杂散电流干扰的实验效果与用计算机软件ANSYS模拟的结果进行比较,进而为消除来自阴极保护设施杂散电流对交叉管线的腐蚀影响提供一定的科学地依据。
Abstract: This paper adopts the method of laboratory simulation to research the effect that using anode in intersections and using coating have on reducing or eliminating the interference of stray current from cathodic protection facilities, and compares the experiment results with the results of computer simulation software ANSYS. Then, this paper provides some scientific basis for eliminateing stray current corrosion influence from cathodic protection facilities to cross pipeline.
文章引用:汪洋, 张亚萍, 韩秀虹, 韩雪, 句东旭, 于濂清, 李焰. 减小来自阴极保护装置杂散电流干扰的实验探究[J]. 现代物理, 2015, 5(3): 65-71. http://dx.doi.org/10.12677/MP.2015.53009

参考文献

[1] 曹阿林 (2010) 埋地金属管线的杂散电流腐蚀防护研究. 重庆大学, 重庆.
[2] 邓树滨 (1995) 杂散电流腐蚀及其对牺牲阳极阴极保护的影响. 材料开发与应用, 2, 41-49.
[3] Metwally, I.A., Al-Mandhari, H.M., Nadir, Z. and Gastli, A. (2007) Boundary element simulation of DC stray currents in oil industry due to cathodic protection interference. European Transactions on Electrical Power, 17, 486-499.
[4] 原著【美】A.W.皮博迪, 主编【美】R.L.比安切蒂, 翻译: 吴建华, 许立坤, 等 (2004) 管线腐蚀控制(原著第二版). 化学工业出版社, 北京, 66-68.
[5] 于家付, 谢娜娜, 吴巍巍, 等 (2013) 埋地金属管道杂散电流腐蚀与防护. 重庆科技学院学报, 2, 89-93.
[6] 唐永祥, 宋生奎, 朱坤峰, 等 (2006) 油气管道的杂散电流腐蚀防护措施. 石油化工安全技术, 4, 26-29.
[7] 祝馨 (2006) 长输管道的腐蚀与防护. 石油化工腐蚀与防护, 1, 51-53.
[8] 赵慧萍, 赵文娟, 张晓芳 (2013) 金属电化学腐蚀与防腐浅析. 化学工程与装备, 10, 135.