催化型燃气泄漏探测器的零点自校正技术研究
Research on Zero Automatic Correction of Catalytic Gas Leak Detector
DOI: 10.12677/JSTA.2017.51002, PDF, HTML, XML, 下载: 1,439  浏览: 3,696 
作者: 吴佳乐:重庆邮电大学信号与信息处理重庆市重点实验室,重庆;牟颖:重庆师范大学计算机与信息科学学院,重庆
关键词: 可燃气体燃气泄漏催化甲烷传感器零点校正Combustible Gas Gas Leakage Catalysis Methane Sensor Zero Automatic Correction
摘要: 本文针对可燃气体监测场所的环境特点,根据催化传感的工作特性,提出了一种催化原理可燃气体探测器的现场零点自校正技术方案。通过实验证明,该方案能很好的解决可燃气体探测器长期零点漂移的问题,具有很高的实用性。
Abstract: This paper aims at the environmental characteristics of the combustible gas monitoring sites, and according to the working characteristics of the catalytic sensor, a new method for zero drift auto-matic correction of catalytic combustible gas detector is proposed. The experimental results show that the proposed scheme can solve the problem of zero drift of combustible gas detector, and has high practicability.
文章引用:吴佳乐, 牟颖. 催化型燃气泄漏探测器的零点自校正技术研究[J]. 传感器技术与应用, 2017, 5(1): 10-15. http://dx.doi.org/10.12677/JSTA.2017.51002

参考文献

[1] 樊雪梅. 浅谈热催化燃烧式甲烷传感器检测瓦斯的适用性[J]. 同煤科技, 2009(3): 19-22.
[2] 曹海燕, 张廷显, 黄秉润. 燃气泄漏监测系统的研究和应用[J]. 煤气与热力, 2015(7): B24-B26.
[3] 尹经梅, 李学勇, 刘金举. 载体催化元件甲烷监测设备调校周期探讨[J]. 山东煤炭科技, 2015(7): 61-62.
[4] 蒋磊, 刘芳华. 催化燃烧型甲烷传感器恒温检测桥路的研究[J]. 工矿自动化, 2006(6): 14-16.
[5] 吕宗宝, 董军, 汝洪芳. 一种基于硬件自校正技术的新型甲烷传感器[J]. 现代仪器, 2010(3): 54-56.