邻苯二胺修饰碳量子点的制备及其对茶叶中痕量铜的分析应用
Determination of Copper in Tea Samples by Phenylenediamine Modified Carbon Dots
DOI: 10.12677/OJNS.2019.73014, PDF,    科研立项经费支持
作者: 黄飞宏, 孙巍巍, 严民民, 柳金枝, 张兰兰, 胡冰倩, 李清媛, 雷雯, 郑彬, 向国强:河南工业大学化学化工学院,河南 郑州
关键词: 碳量子点邻苯二胺茶叶样品Carbon Dots Copper Phenylenediamine Tea Samples
摘要: 以柠檬酸为碳源,通过水热法制备了碳量子点(CDs);然后通过-NH2与-COOH之间的偶联反应,将邻苯二胺(OPD)修饰到CDs表面,得到了邻苯二胺修饰荧光碳点(CDs-OPD)。采用UV-vis,FT-IR和荧光光谱对所制备的CDs-OPD进行光学性质表征。结果表明,与未经OPD修饰的CDs相比,当激发波长为260 nm时,CDs-OPD出现了新的荧光发射峰(295 nm,440 nm和580 nm)。Cu2+能够与CDs-OPD表面的基团作用,使得CDs-OPD在295 nm处荧光峰产生明显猝灭,且荧光猝灭程度与加入Cu2+的浓度呈线性关系。据此建立了基于CDs-OPD的荧光猝灭分析Cu2+的新方法,方法检测限(3σ)为1.4ng mL−1,相对标准偏差(RSD)为5.0% (C = 100 ng mL−1, n = 11),线性范围为10~500 ng mL−1,所建立的分析方法成功应用于茶叶样品中痕量Cu2+的测定,结果满意。
Abstract: CDs was prepared by hydrothermal method using citric acid as a carbon source. By coupling reac-tion between -NH2 and -COOH, the o-phenylenediamine (OPD) was grafted to the surface of CDs, and the phthalic two amine modified fluorescent carbon dots (CDs-OPD) was obtained. The optical properties of the prepared CDs-OPD were characterized by UV-vis, FT-IR and fluorescence spec-troscopy. The results show that CDs-OPD has a three fluorescence emission peaks (295 nm, 440 nm and 580 nm) with an excitation wavelength of 260 nm, compared with the CDs without OPD modification. The effects of metal ions on the fluorescence properties of CDs-OPD were investigated. The results showed that Cu2+ could selectively quencher the fluorescence of CDs-OPD, and other metal ions did not produce obvious fluorescence quenching. Cu2+ can interact with the groups on the surface of CDs-OPD, which makes the fluorescence peak (295 nm) of CDs-OPD obviously quenched, and the degree of fluorescence quenching is linear with the concentration of Cu2+. A new analytical method for Cu2+ based on CDs-OPD was established. The detection limit (3σ) was 1.4 ng mL−1, the relative standard deviation (RSD) was 5% (C = 100 ng mL−1, n = 11), and the linear range was 10 - 500 ng mL−1. The developed method was successfully applied to the determination of trace amounts in tea samples. The results were satisfactory.
文章引用:黄飞宏, 孙巍巍, 严民民, 柳金枝, 张兰兰, 胡冰倩, 李清媛, 雷雯, 郑彬, 向国强. 邻苯二胺修饰碳量子点的制备及其对茶叶中痕量铜的分析应用[J]. 自然科学, 2019, 7(3): 88-95. https://doi.org/10.12677/OJNS.2019.73014

参考文献

[1] Zhang, Y.H., Zhang, H.S., Guo, X.F., et al. (2008) L-Cysteine-Coated CdSe/CdS Core-Shell Quantum Dots as Selective Fluorescence Probe for Copper(II) Determination. Microchemical Journal, 89, 142-147. [Google Scholar] [CrossRef
[2] Liu, Z.Q., Liu, S.P., Yin, P.F., et al. (2012) Fluorescence Enhancement of CdTe/CdS Quantum Dots by Coupling of Glyphosate and Its Application for Sensitive Detection of Copper Ion. Analytica Chimica Acta, 745, 78-84. [Google Scholar] [CrossRef] [PubMed]
[3] Chan, Y.H., Chen, J.X., Liu, Q.S., et al. (2010) Ultrasensitive Copper (II) Detection Using Plasmon-Enhanced and Photo-Brightened Luminescence of CdSe Quantum Dots. Analytical Chemistry, 82, 3671-3678. [Google Scholar] [CrossRef] [PubMed]
[4] Xie, C.L., Xiao, L., Peng, S.Z., et al. (2014) Preparation of Novel Magnetic and Fluorescent CS-Fe3O4@CdSeS Nano-particles for Simultaneous Removal and Optical Determination of Trace Copper Ions. New Journal of Chemistry, 38, 6095-6102. [Google Scholar] [CrossRef
[5] Soylak, M. and Erbas, Z. (2017) Magnetic Solid Phase Extraction of Trace Lead and Copper on Chromotrope FB Im-pregnated Magnetic Multiwalled Carbon Nanotubes From Cigarette and Hair Samples for Measurement by Flame AAS. Atomic Spectroscopy, 38, 57-61.
[6] Trak, D., Kenduzler, E. and Arslan, Y. (2016) Determination of Copper in Water and Walnuts by Solid Phase Extraction and Slotted Quartz Tube Flame Atomic Absorption Spectrometry. Analytical Letters, 49, 1589-1599. [Google Scholar] [CrossRef
[7] Shoaee, H., Roshdi, M., Khanlarzadeh, N., et al. (2012) Simultaneous Preconcentration of Copper and Mercury in Water Samples by Cloud Point Extraction and Their Determination by Inductively Coupled Plasma Atomic Emission Spectrometry. Spectrochimica Acta Part A: Molecular & Biomolecular Spectroscopy, 98, 70. [Google Scholar] [CrossRef] [PubMed]
[8] Faraji, M., Yamini, Y., Shariati, S., et al. (2009) Application of Cotton as a Solid Phase Extraction Sorbent for On-Line Preconcentration of Copper in Water Samples Prior to Inductively Coupled Plasma Optical Emission Spectrometry Determination. Journal of Hazardous Materials, 166, 1383-1388. [Google Scholar] [CrossRef] [PubMed]
[9] Rapp, I., Schlosser, C., Rusiecka, D., et al. (2017) Automated Preconcentration of Fe, Zn, Cu, Ni, Cd, Pb, Co, and Mn in Seawater with Analysis Using High-Resolution Sector Field Inductively-Coupled Plasma Mass Spectrometry. Analytica Chimica Acta, 976, 1-13. [Google Scholar] [CrossRef] [PubMed]
[10] Lin, X.M., Gao, G.M., Zheng, L.Y., et al. (2014) Encapsulation of Strongly Fluorescent Carbon Quantum Dots in Met-al-Organic Frameworks for Enhancing Chemical Sensing. Analytical Chemistry, 86, 1223-1228.
[11] Dong, Y.Q., Wang, R.X., Li, G.L., et al. (2012) Polyamine-Functionalized Carbon Quantum Dots as Fluorescent Probes for Selective and Sensitive Detection of Copper Ions. Analytical Chemistry, 84, 6220-6224. [Google Scholar] [CrossRef] [PubMed]
[12] Liu, S., Tian, J., Wang, L., et al. (2012) Hydrothermal Treatment of Grass: A Low Cost, Green Route to Nitrogen-Doped, Carbon-Rich, Photoluminescent Polymer Nanodots That Can Be Used as an Effective Fluorescent Sensing Platform for Label-Free Sensitive and Selective Detection of Cu(II) Ions. Advanced Materials, 24, 2037-2041. [Google Scholar] [CrossRef] [PubMed]
[13] 唐荣, 李琛, 叶志强, 等. 柠檬酸荧光碳点的合成及其在Fe(III)检测和细胞成像中的应用[J]. 分析科学学报, 2015, 31(1): 6-12.
[14] Yang, J.A., He, X.W., Chen, L.X., et al. (2016) The Selective Detection of Galactose Based on Boronic Acid Func-tionalized Fluorescent Carbon Dots. Analytical Methods, 8, 8345-8351. [Google Scholar] [CrossRef