温度效应对超长连体结构的影响分析
Temperature Effects Analysis of a Super-Long Connective Structure
DOI: 10.12677/HJCE.2020.95043, PDF, HTML, XML, 下载: 513  浏览: 2,136 
作者: 高 超, 周永明, 徐伟斌:浙江省建筑设计研究院,浙江 杭州;吴能文:浙江翰城建筑设计有限公司,浙江 义乌
关键词: 温度效应超长连体刚性连接Temperature Effects Super-Long Conjoined Structure Rigid Connections
摘要: 刚性连接的连体部位楼层常形成超长结构,在水平温差作用下,两侧塔楼竖向构件对混凝土楼层沿水平方向变形产生较大约束,塔楼竖向构件受到相应的水平剪力作用。大跨度超长连体结构设计中温度效应非常明显,应进行水平温度效应分析。通过某大跨超长连体结构算例,得出了连体两侧塔楼竖向抗侧力构件在水平温度作用下的受力变化和连体部位楼板应力分布特征。针对温度效应的影响范围和薄弱部位,给出了相关设计建议和加强措施。
Abstract: Conjoined parts of the floor by rigid connections often form a super-long structure. Under the action of horizontal temperature difference, vertical elements of towers on both sides have a great constraint on the horizontal deformation of the concrete floors. The vertical members of the tower are subject to the corresponding horizontal shear force. The temperature effect is very obvious in the design of long span super-long conjoined structure, so the horizontal temperature effect should be analyzed. Based on an example of a long span super-long conjoined structure, the stress changes of the vertical lateral force-resisting members of the conjoined towers on both sides under the action of horizontal temperature and the stress distribution characteristics of the floor slab at the conjoined parts are obtained. According to the influence range and weak position of temperature effect, some design suggestions and strengthening measures are given.
文章引用:高超, 吴能文, 周永明, 徐伟斌. 温度效应对超长连体结构的影响分析[J]. 土木工程, 2020, 9(5): 407-413. https://doi.org/10.12677/HJCE.2020.95043

参考文献

[1] 中华人民共和国住房和城乡建设部. JGJ3-2010高层建筑混凝土结构技术规程[S]. 北京: 中国建筑工业出版社, 2011.
[2] 中华人民共和国住房和城乡建设部. GB50010-2010混凝土结构设计规范(2015年版) [S]. 北京: 中国建筑工业出版社, 2015.
[3] 中华人民共和国住房和城乡建设部. GB50009-2012建筑结构荷载规范[S]. 北京: 中国建筑工业出版社, 2012.
[4] 王铁梦. 工程结构裂缝控制[M]. 北京: 中国建筑工业出版社, 2004.