碘量法测定水质样品溶解氧结果的不确定度评定
Evaluation of Uncertainty in the Determination Results of Dissolved Oxygen in Water Samples by Iodometric Method
DOI: 10.12677/JWRR.2023.123033, PDF, 下载: 141  浏览: 206 
作者: 林桂芝, 李 强, 张晓云, 张亚平, 胡转玲:核工业二〇三研究所分析测试中心,陕西 西安
关键词: 溶解氧碘量法测定结果不确定度评定Dissolved Oxygen Iodometric Method Determination Results Evaluation of Uncertainty
摘要: 本文依据GB/T27418-2017《测量不确定度评定与表示》对运用GB 7489-1987《水质溶解氧的测定碘量法》测定水质样品中溶解氧含量进行了不确定度评定;在实际工作中系统地运用不确定度评定方法对环境水样品测定溶解氧过程中的不确定度分量进行了分析和量化,求出溶解氧测定结果的合成标准不确定度和扩展不确定度分别为0.102 mg/L和0.204 mg/L;并对容量法的测量不确定度评定进行了概括与总结,具有一定的实用性与指导意义。
Abstract: Based on GB/T27418-2017 Guide to the Evaluation and Expression of Uncertainty in Measurement, this paper evaluates the uncertainty in the determination of dissolved oxygen (DO) in water environment samples by GB 7489-1987 Water quality-Determination of dissolved oxygen-Iodometric method. In practical work, the uncertainty components in the determination of DO in water samples are analyzed and quantified using the method of uncertainty evaluation, and the combined standard uncertainty and the expanded uncertainty of the determination result of DO are 0.102 mg/L and 0.204 mg/L respectively. The evaluation of measurement uncertainty of the volumetric method is summarized, which has certain practicability and guiding significance.
文章引用:林桂芝, 李强, 张晓云, 张亚平, 胡转玲. 碘量法测定水质样品溶解氧结果的不确定度评定[J]. 水资源研究, 2023, 12(3): 287-295. https://doi.org/10.12677/JWRR.2023.123033

参考文献

[1] 国家环境保护局. GB/T7489-1987水质溶解氧的化学分析方法[S]. 北京: 中国标准出版社, 1987. National Environmental Protection Agency. GB/T7489-1987 Water quality-determination of dissolved oxygen-iodometric method. Beijing: Standards Press of China, 1987. (in Chinese)
[2] 中华人民共和国国家质量监督检验检疫总局, 中国国家标准化管理委员会. GB17378.4-2007海洋监测规范——第四部分: 海水分析31溶解氧——碘量法[S]. 北京: 中国标准出版社, 2008. General Administration of Quality Supervision, Inspection and Quarantine—The People’s Republic of China, Standardization Administration of China. GB17378.4-2007 The specification for marine monitoring—Part 4: Seawater analysis 31 dissolved oxygen—Iodometric method. Beijing: Standards Press of China, 2008. (in Chinese)
[3] 环境保护部. HJ506-2009水质溶解氧的测定——电化学探头法[S]. 北京: 中国标准出版社, 2009. Ministry of Environmental Protection. HJ506-2009 Water quality, determination of dissolved oxygen—Electrochemical probe method. Beijing: Standards Press of China, 2009. (in Chinese)
[4] 国家质量监督检验检疫总局. JJG 291-2018溶解氧测定仪检定规程[S]. 北京: 中国标准出版社, 2018. General Administration of Quality Supervision, Inspection and Quarantine. JJG 291-2018 Verification regulation dissolved oxygen meters. Beijing: Standards Press of China, 2018. (in Chinese)
[5] 安卫东, 陶良瑛. 碘量法测定水中溶解氧含量测量不确定度的评定[J]. 化学分析计量, 2003(6): 7-9. AN Weidong, TAO Liangying. Evaluation of uncertainty in measurement of dissolved oxygen in water by iodometric method. Chemical Analysis and Meterage, 2003(6): 7-9. (in Chinese)
[6] 蔡大川, 罗军, 何冬琦. 溶解氧测定仪示值误差的不确定度的评定[J]. 化学分析计量, 2005(4): 11-12. CAI Dachuan, LUO Jun and HE Dongqi. Evaluation of uncertainty on indication error of dissolved oxygen meter. Chemical Analysis and Meterage, 2005(4): 11-12. (in Chinese)
[7] 李建. 溶解氧测定仪示值误差检定结果的不确定度的评定[J]. 计量与测试技术, 2020(7): 106-108. LI Jian. Evaluation of measurement uncertainty on the verification result of indication error of dissolved oxygen meter. Metrology and Measurement Technique, 2020(7): 106-108. (in Chinese)
[8] 中华人民共和国国家质量监督检验检疫总局, 中国国家标准化管理委员会. GB/T27418-2017测量不确定度评定与表示方法[S]. 北京: 中国标准出版社, 2018. General Administration of Quality Supervision, Inspection and Quarantine—The People’s Republic of China, Standardization Administration of China. GB/T27418-2017 Guide to the evaluation and expression of uncertainty in measurement. Beijing: Standards Press of China, 2018. (in Chinese)
[9] 乔文生. 钢铁及其合金中铬含量测定结果的不确定度评定[J]. 化学分析计量, 2004(2): 4-6. QIAO Wensheng. Evaluation of the uncertainty of the measurement result for determination of chromium content in steel and its alloys. Chemical Analysis and Meterage, 2004(2): 4-6. (in Chinese)