三相三电平NPC整流器开路故障诊断与容错控制策略的研究
Research on Open-Circuit Fault Diagnosis and Fault-Tolerant Control Strategy of Three-Phase Three-Level NPC Rectifier
DOI: 10.12677/AEPE.2021.95027, PDF,  被引量   
作者: 朱 叶, 戴 勇*:南京师范大学电气与自动化工程学院,江苏 南京;张 倩:扬州大学广陵学院,江苏 扬州;华 梅:南京国联电力工程设计有限公司,江苏 南京
关键词: 三电平整流器开路故障故障诊断容错控制Three-Level Rectifier Open-Circuit Fault Fault Diagnosis Fault-Tolerant Control
摘要: 近年来,三相三电平NPC整流器在高压、大功率领域得到广泛应用,为了提高NPC三电平整流器运行的安全可靠性,研究其故障诊断和容错控制显得尤为重要。本文详细分析了整流器各开关器件发生开路故障后的电流路径和故障特征的变化,提出了一种基于电流路径的故障诊断方法;接着分析了开关管开路故障对空间电压矢量的影响,提出了一种基于参考电压矢量修正的容错控制策略。本文提出的故障诊断方法能准确定位故障开关器件,无需大量的计算且诊断迅速;所提出的容错控制方法无需增加额外的硬件,能有效提高NPC三电平整流器的可靠性。最后,通过仿真验证了所提方法的有效性。
Abstract: In recent years, the three-phase three-level NPC rectifier has been widely used in high voltage and high power fields. In order to improve the safety and reliability of NPC three-level rectifier opera-tion, it is particularly important to study its fault diagnosis and fault-tolerant control. In this paper, the changes of current flow path and fault characteristics of each switch device after open-circuit fault are analyzed in detail, and a fault diagnosis method based on current path is adopted. Then, the influence of the open-circuit fault of switch tube on space voltage vector is analyzed, and a fault-tolerant control strategy based on reference voltage vector correction is proposed. The fault detection method used in this paper can accurately locate the fault switch device, without a lot of calculation and rapid diagnosis. The proposed fault-tolerant control method does not need addi-tional hardware, which can effectively improve the reliability of NPC three-level rectifier. Finally, the effectiveness of the proposed method is verified by simulation.
文章引用:朱叶, 张倩, 华梅, 戴勇. 三相三电平NPC整流器开路故障诊断与容错控制策略的研究[J]. 电力与能源进展, 2021, 9(5): 250-262. https://doi.org/10.12677/AEPE.2021.95027

参考文献

[1] 金红元, 邹云屏, 林磊, 陈伟, 邹旭东, 钟和清, 等. 三电平PWM整流器双环控制技术及中点电压平衡控制技术的研究[J]. 中国电机工程学报, 2006, 26(20): 64-68.
[2] Yang, S., Xiang, D., Bryant, A., Mawby, P., Ran, L. and Tavner, P. (2011) Condition Monitoring for Device Reliability in Power Electronic Converters: A Review. IEEE Trans-actions on Power Electronics, 25, 2734-2752. [Google Scholar] [CrossRef
[3] Li, X., Xu, D., Zhu, H., Cheng, X., Yu, Y. and Ng, W.T. (2018) An Indirect IGBT Over-Current Detection Technique via Gate Voltage Monitoring and Analyzing. IEEE Transactions on Power Electronics, 34, 3615-3622. [Google Scholar] [CrossRef
[4] Azer, P., Ouni, S. and Narimani, M. (2020) A Novel Fault-Tolerant Technique for Active Neutral Point Clamped Inverter Using Carrier-Based PWM. IEEE Transactions on Industrial Electronics, 67, 1792-1803. [Google Scholar] [CrossRef
[5] Chen, Z.W., Ding, S.X., Peng, T., Yang, C. and Gui, W. (2018) Fault Detection for Non-Gaussian Processes Using Generalized Canonical Correlation Analysis and Randomized Algo-rithms. IEEE Transactions on Industrial Electronics, 65, 1559-1567. [Google Scholar] [CrossRef
[6] Mendes, A.M.S., Abadi, M.B. and Cruz, S. (2014) Fault Diag-nostic Algorithm for Three-Level Neutral Point Clamped AC Motor Drives, Based on the Average Current Park’s Vector. IET Power Electronics, 7, 1127-1137. [Google Scholar] [CrossRef
[7] Sanchez, J.P., Campos-Delgado, D.U., Espinoza-Trejo, D.R., Val-dez-Fernández, A.A. and De Angelo, C.H. (2019) Fault Diagnosis in Grid-Connected PV NPC Inverters by a Mod-el-Based and Data Processing Combined Approach. IET Power Electronics, 12, 3254-3264. [Google Scholar] [CrossRef
[8] Ge, X., Pu, J., Gou, B. and Liu, Y.-C. (2018) An Open-Circuit Fault Diagnosis Approach for Single-Phase Three-Level Neutral-Point-Clamped Converters. IEEE Transactions on Power Electronics, 33, 2559-2570. [Google Scholar] [CrossRef
[9] Caseiro, L.M.A. and Mendes, A.M.S. (2015) Real-Time IGBT Open-Circuit Fault Diagnosis in Three-Level Neutral-Point-Clamped Voltage-Source Rectifiers Based on Instant Voltage Error. IEEE Transaction on Industrial Electronics, 62, 1669-1678. [Google Scholar] [CrossRef
[10] Caseiro, L.M.A. and Mendes, A.M.S. (2015) Real-Time Multiple IGBT Open-Circuit Fault Diagnosis in Three-Level Neutral-Point-Clamped Converters with No Additional Sensors. IECON 2015-41st Annual Conference of the IEEE Industrial Electronics Society, Yokohama, 9-12 November 2015, 3181-3186. [Google Scholar] [CrossRef
[11] Cheng, S., Chen, Y.T., Yu, T.J. and Wu, X. (2016) A Novel Diagnostic Technique for Open-Circuited Faults of Inverters Based on Output Line-to-Line Voltage Model. IEEE Transactions on Industrial Electronics, 63, 4412-4421. [Google Scholar] [CrossRef
[12] 许伟奇, 张斌, 汶雪. 基于分数阶滑模观测器的三相八开关容错逆变器驱动永磁同步电机系统无传感器FCS-MPC [J]. 控制理论与应用, 2018, 35(7): 1037-1049.
[13] Li, J., Huang, A.Q., Liang, Z. and Bhattacharya, S. (2012) Analysis and Design of Active NPC (ANPC) Inverters for Fault-Tolerant Operation of High-Power Electrical Drives. IEEE Transactions on Power Electronics, 27, 519-533. [Google Scholar] [CrossRef
[14] Lee, J.S. and Lee, K.B. (2015) Open-Switch Fault Tolerance Control for a Three-Level NPC/T-Type Rectifier in Wind Turbine Systems. IEEE Transactions on Industrial Electronics, 62, 1012-1021. [Google Scholar] [CrossRef
[15] Lee, J.S. and Lee, K.B. (2015) Open-Circuit Fault-Tolerant Con-trol for Outer Switches of Three-Level Rectifiers in Wind Turbine Systems. IEEE Transactions on Power Electronics, 31, 3806-3815. [Google Scholar] [CrossRef
[16] Katebi, R., He, J. and Weise, N. (2018) An Advanced Three-Level Active Neutral-Point-Clamped Converter with Improved Fault-Tolerant Capabilities. IEEE Transactions on Power Electronics, 33, 6897-6909. [Google Scholar] [CrossRef