基于无线传输的多参量数据汇集接地监测装置研究
Research on Multi Parameter Data Collection Grounding Monitoring Device Based on Wireless Transmission
摘要: 输电线路杆塔的接地电阻是衡量决定电力系统防雷性能的重要因素之一,因此电力行业相关规范要求定期测量接地电阻,从而保障输电线路安全稳定的运行。基于无线传输的多参量数据汇集接地监测装置能够实现杆塔接地电阻的实时测量,能够为特殊情形下获取输电线路技术参数提供了技术保障,解决了偏远地区难以到达现场测量的问题,并在接地电阻测量的同时,将其影响因素的多参数汇集并无线上传至中心服务器,构建完整可靠的接地监测系统。
Abstract: The grounding resistance of transmission line towers is one of the key factors in assessing the lightning protection performance of power systems. Therefore, industry standards regular measurement of grounding resistance to ensure the safe and stable operation of transmission lines. The multi-parameter data collection grounding monitoring device based on wireless transmission can achieve real-time of tower grounding resistance, providing technical support for obtaining technical parameters of transmission lines under special circumstances. It solves the problem of difficult on-site measurement in remote areas, at the same time, collects multiple parameters that affect the grounding resistance and uploads them wirelessly to the central server, building a complete and reliable grounding monitoring system.
参考文献
|
[1]
|
崔志斌. 输电线路杆塔接地电阻测量方法及其重要性[J]. 消费电子, 2014(12): 67-67.
|
|
[2]
|
王海生, 曹建强, 刘文恒, 等. 针对直击雷与感应雷的输电线路杆塔冲击接地电阻测量装置的应用[J]. 内蒙古电力技术, 2017, 35(2): 50-53.
|
|
[3]
|
张天亮. 杆塔接地电阻监测系统的研究[D]: [硕士学位论文]. 济南: 山东建筑大学, 2012.
|
|
[4]
|
国家能源局. 架空输电线路运行规程: DL/T 741-2019 [S]. 2019.
|
|
[5]
|
林健. 电气自动化在电力系统中的运用[J]. 科技资讯, 2024, 22(16): 95-97.
|
|
[6]
|
肖琼, 刘小保. 接地电阻测试的新方法——异频法[J]. 广播电视信息, 2011, 18(9): 73-74.
|