复合牙齿模型在无托槽隐形矫治中的研究进展
Research Progress on Composite Tooth Models in Clear Aligner Therapy
DOI: 10.12677/acm.2026.162754, PDF,   
作者: 龚唯一, 郑雷蕾*:重庆医科大学附属口腔医院,重庆;口腔疾病研究重庆市重点实验室,重庆;口腔生物医学工程重庆市高校市级重点实验室,重庆;重庆市卫生健康委口腔生物医学工程重点实验室,重庆
关键词: 复合牙齿模型无托槽隐形矫治临床应用Composite Tooth Model Clear Aligner Therapy Clinical Application
摘要: 长期以来,CBCT和数字化模型广泛应用于口腔医学领域,在正畸学特别是无托槽隐形矫治中应用较多,大大帮助了临床医生诊断和治疗疾病,对治疗效果也有显著提升。然而,CBCT与数字化模型结合形成的复合牙齿模型在无托槽隐形矫治中的应用仍处于早期阶段。本文的目的是强调复合牙齿模型在无托槽隐形矫治中的应用,并阐述CBCT和数字化模型在无托槽隐形矫治中的应用。分析表明,将复合牙齿模型应用于无托槽隐形矫治可以帮助正畸医生进行诊断、治疗模拟、定制矫治器制作、检测正畸治疗期间和之后的牙根运动。
Abstract: For a long time, CBCT and digital models have been widely used in dental medicine, with particularly frequent applications in orthodontics, especially for clear aligner therapy. They have greatly assisted clinicians in diagnosing and treating conditions and have significantly improved treatment outcomes. However, the application of composite tooth models, which integrate CBCT and digital model data, in clear aligner therapy is still in its early stages. The purpose of this study is to highlight the use of composite tooth models in clear aligner therapy and to describe the roles of CBCT and digital models in this context. Analysis indicates that applying composite tooth models in clear aligner treatment can assist orthodontists in diagnosis, treatment simulation, custom aligner fabrication, and monitoring tooth root movement during and after treatment.
文章引用:龚唯一, 郑雷蕾. 复合牙齿模型在无托槽隐形矫治中的研究进展[J]. 临床医学进展, 2026, 16(2): 3392-3397. https://doi.org/10.12677/acm.2026.162754

参考文献

[1] Cardoso, P.C., Espinosa, D.G., Mecenas, P., et al. (2020) Pain Level between Clear Aligners and Fixed Appliances: A Systematic Review. Progress in Orthodontics, 21, Article No. 3. [Google Scholar] [CrossRef] [PubMed]
[2] Harris, K., Ojima, K., Dan, C., et al. (2020) Evaluation of Open Bite Closure Using Clear Aligners: A Retrospective Study. Progress in Orthodontics, 21, Article No. 23. [Google Scholar] [CrossRef] [PubMed]
[3] Weir, T. (2017) Clear Aligners in Orthodontic Treatment. Australian Dental Journal, 62, 58-62. [Google Scholar] [CrossRef] [PubMed]
[4] 金作林. 无托槽隐形矫治技术对于不同错(牙合)畸形的分级诊治[J]. 实用口腔医学杂志, 2021, 37(6): 733-738.
[5] Gandhi, V., Mehta, S., Gauthier, M., et al. (2021) Comparison of External Apical Root Resorption with Clear Aligners and Pre-Adjusted Edgewise Appliances in Non-Extraction Cases: A Systematic Review and Meta-Analysis. European Journal of Orthodontics, 43, 15-24. [Google Scholar] [CrossRef] [PubMed]
[6] Rossini, G., Parrini, S., Castroflorio, T., et al. (2015) Periodontal Health during Clear Aligners Treatment: A Systematic Review. European Journal of Orthodontics, 37, 539-543. [Google Scholar] [CrossRef] [PubMed]
[7] Baldwin, D.K., King, G., Ramsay, D.S., et al. (2008) Activation Time and Material Stiffness of Sequential Removable Orthodontic Appliances. Part 3: Premolar Extraction Patients. American Journal of Orthodontics and Dentofacial Orthopedics, 133, 837-845. [Google Scholar] [CrossRef] [PubMed]
[8] Aman, C., Azevedo, B., Bednar, E., et al. (2018) Apical Root Resorption during Orthodontic Treatment with Clear Aligners: A Retrospective Study Using Cone-Beam Computed Tomography. American Journal of Orthodontics and Dentofacial Orthopedics, 153, 842-851. [Google Scholar] [CrossRef] [PubMed]
[9] Mozzo, P., Procacci, C., Tacconi, A., et al. (1998) A New Volumetric CT Machine for Dental Imaging Based on the Cone-Beam Technique: Preliminary Results. European Radiology, 8, 1558-1564. [Google Scholar] [CrossRef] [PubMed]
[10] 张倩倩, 于艳玲. CBCT应用于口腔正畸领域的研究进展[J]. 中华口腔正畸学杂志, 2013(3): 170-172.
[11] Rossini, G., Parrini, S., Castroflorio, T., et al. (2016) Diagnostic Accuracy and Measurement Sensitivity of Digital Models for Orthodontic Purposes: A Systematic Review. American Journal of Orthodontics and Dentofacial Orthopedics, 149, 161-170. [Google Scholar] [CrossRef] [PubMed]
[12] Ender, A., Attin, T. and Mehl, A. (2016) In Vivo Precision of Conventional and Digital Methods of Obtaining Complete-arch Dental Impressions. The Journal of Prosthetic Dentistry, 115, 313-320. [Google Scholar] [CrossRef] [PubMed]
[13] Ender, A., Zimmermann, M., Attin, T., et al. (2016) In Vivo Precision of Conventional and Digital Methods for Obtaining Quadrant Dental Impressions. Clinical Oral Investigations, 20, 1495-1504. [Google Scholar] [CrossRef] [PubMed]
[14] Flügge, T.V., Schlager, S., Nelson, K., et al. (2013) Precision of Intraoral Digital Dental Impressions with iTero and Extraoral Digitization with the iTero and a Model Scanner. American Journal of Orthodontics and Dentofacial Orthopedics, 144, 471-478. [Google Scholar] [CrossRef] [PubMed]
[15] Garcia-Figueroa, M.A., Raboud, D.W., Lam, E.W., Heo, G. and Major, P.W. (2008) Effect of Buccolingual Root Angulation on the Mesiodistal Angulation Shown on Panoramic Radiographs. American Journal of Orthodontics and Dentofacial Orthopedics, 134, 93-99. [Google Scholar] [CrossRef] [PubMed]
[16] Mckee, I.W., Glover, K.E., Williamson, P.C., Lam, E.W., Heo, G. and Major, P.W. (2001) The Effect of Vertical and Horizontal Head Positioning in Panoramic Radiography on Mesiodistal Tooth Angulations. The Angle Orthodontist, 71, 442-451.
[17] Song, I.T., Cho, J.H., Chae, J.M. and Chang, N.Y. (2011) Evaluation of Mesiodistal Tooth Axis Using a CBCT-Generated Panoramic View. The Korean Journal of Orthodontics, 41, 255-267. [Google Scholar] [CrossRef
[18] Lascala, C.A., Panella, J. and Marques, M.M. (2004) Analysis of the Accuracy of Linear Measurements Obtained by Cone Beam Computed Tomography (CBCT-NewTom). Dentomaxillofacial Radiology, 33, 291-294. [Google Scholar] [CrossRef] [PubMed]
[19] Sameshima, G.T. (2012) A New Method to Measure Mesiodistal Angulation and Faciolingual Inclination of Each Whole Tooth with Volumetric Cone-Beam Computed Tomography Images. American Journal of Orthodontics and Dentofacial Orthopedics, 142, 133-143. [Google Scholar] [CrossRef] [PubMed]
[20] Ender, A. and Mehl, A. (2011) Full Arch Scans: Conventional versus Digital Impressions—An In-Vitro Study. International Journal of Computerized Dentistry, 14, 11-21.
[21] Hayashi, K., Sachdeva, A.U., Saitoh, S., Lee, S.P., Kubota, T. and Mizoguchi, I. (2013) Assessment of the Accuracy and Reliability of New 3-Dimensional Scanning Devices. American Journal of Orthodontics and Dentofacial Orthopedics, 144, 619-625. [Google Scholar] [CrossRef] [PubMed]
[22] Sun, L., Lee, J.S., Choo, H.H., Hwang, H.S. and Lee, K.M. (2018) Reproducibility of an Intraoral Scanner: A Comparison between In-Vivo and Ex-Vivo Scans. American Journal of Orthodontics and Dentofacial Orthopedics, 154, 305-310. [Google Scholar] [CrossRef] [PubMed]
[23] Lim, S.W., Hwang, H.S., Cho, I.S., Baek, S.H. and Cho, J.H. (2020) Registration Accuracy between Intraoral-Scanned and Cone-Beam Computed Tomography-Scanned Crowns in Various Registration Methods. American Journal of Orthodontics and Dentofacial Orthopedics, 157, 348-356. [Google Scholar] [CrossRef] [PubMed]
[24] Macchi, A., Carrafiello, G., Cacciafesta, V. and Norcini, A. (2006) Three-Dimensional Digital Modeling and Setup. American Journal of Orthodontics and Dentofacial Orthopedics, 129, 605-610. [Google Scholar] [CrossRef] [PubMed]
[25] Guo, H., Zhou, J., Bai, Y. and Li, S. (2011) A Three-Dimensional Setup Model with Dental Roots. Journal of Clinical Orthodontics, 45, 209-216.
[26] Kihara, T., Tanimoto, K., Michida, M., Yoshimi, Y., Nagasaki, T., Murayama, T., et al. (2012) Construction of Orthodontic Setup Models on a Computer. American Journal of Orthodontics and Dentofacial Orthopedics, 141, 806-813. [Google Scholar] [CrossRef] [PubMed]
[27] Lee, R.J., Pham, J., Choy, M., Weissheimer, A., Dougherty Jr., H.L., Sameshima, G.T., et al. (2014) Monitoring of Typodont Root Movement via Crown Superimposition of Single Cone-Beam Computed Tomography and Consecutive Intraoral Scans. American Journal of Orthodontics and Dentofacial Orthopedics, 145, 399-409. [Google Scholar] [CrossRef] [PubMed]
[28] Lee, R.J., Weissheimer, A., Pham, J., Go, L., de Menezes, L.M., Redmond, W.R., et al. (2015) Three-Dimensional Monitoring of Root Movement during Orthodontic Treatment. American Journal of Orthodontics and Dentofacial Orthopedics, 147, 132-142. [Google Scholar] [CrossRef] [PubMed]
[29] Lee, R.J., Pi, S., Park, J., Devgon, D., Nelson, G., Hatcher, D., et al. (2018) Accuracy and Reliability of the Expected Root Position Setup Methodology to Evaluate Root Position during Orthodontic Treatment. American Journal of Orthodontics and Dentofacial Orthopedics, 154, 583-595. [Google Scholar] [CrossRef] [PubMed]
[30] Lo Russo, L., Lorusso, M., Ercoli, C., et al. (2025) Effect of the CBCT Data Segmentation Threshold on Registration Accuracy with Surface Scanning. The Journal of Prosthetic Dentistry. [Google Scholar] [CrossRef
[31] Zhang, Y.S., Liu, Y.X., Liu, T.Q., et al. (2024) Evaluation of CBCT Reconstructed Tooth Models at Different Thresholds and Voxels and Their Accuracy in Fusion with IOS Data: An in Vitro Validation Study. BMC Oral Health, 24, Article No. 1571. [Google Scholar] [CrossRef] [PubMed]
[32] 王斯维, 刘怡. 三维头影测量的研究现状与展望[J]. 中华口腔正畸学杂志, 2016(1): 33-38.
[33] Park, T.J., Lee, S.H. and Lee, K.S. (2012) A Method for Mandibular Dental Arch Superimposition Using 3D Cone Beam CT and Orthodontic 3D Digital Model. The Korean Journal of Orthodontics, 42, 169-181. [Google Scholar] [CrossRef] [PubMed]
[34] 傅民魁, 主编, 丁寅, 王林, 邓锋, 等, 编. 口腔正畸学供口腔医学类专业用[M]. 第6版. 北京: 人民卫生出版社, 2012: 358.
[35] Hou, D., Capote, R., Bayirli, B., et al. (2020) The Effect of Digital Diagnostic Setups on Orthodontic Treatment Planning. American Journal of Orthodontics and Dentofacial Orthopedics, 157, 542-549. [Google Scholar] [CrossRef] [PubMed]
[36] 叶年嵩, 房兵. 数字化正畸发展现状[J]. 实用口腔医学杂志, 2022, 38(6): 707-712.
[37] Sang, Y.H., Hu, H.C., Lu, S.H., Wu, Y.W., Li, W.R. and Tang, Z.H. (2016) Accuracy Assessment of Three-Dimensional Surface Reconstructions of in Vivo Teeth from Cone-Beam Computed Tomography. Chinese Medical Journal, 129, 1464-1470. [Google Scholar] [CrossRef] [PubMed]
[38] Lim, S., Moon, R., Kim, M., Oh, M., Lee, K., Hwang, H., Kim, T., Baek, S. and Cho, J. (2020) Construction Reproducibility of a Composite Tooth Model Composed of an Intraoral-Scanned Crown and a Cone-Beam Computed Tomography-Scanned Root. Korean Journal of Orthodontics, 50, 229-237. [Google Scholar] [CrossRef] [PubMed]