三维成像扫描在上肢尺寸测量中的 应用研究
A Study on the Application of Three-Dimensional Imaging Scanner in Upper Limb Dimensional Measurement
DOI: 10.12677/acm.2026.1641744, PDF,   
作者: 李 鹏, 孙 义, 毋 荣, 孙剑端, 刘雯雯, 张 雯, 乔霞霞, 李霁锋, 王龙虎*:兵器工业总医院康复医学科,陕西 西安
关键词: 三维扫描肢体尺寸排水法Three-Dimensional Scanning Limb Size Drainage Method
摘要: 目的:定量评价三维成像扫描方法对人体上肢的周径、长度、体积测量的实用性、简便性及准确性,并与传统测量方法比较分析。方法:前瞻性纳入31名受试者进行上肢尺寸研究,利用3D扫描系统装置对上肢尺寸扫描、感兴趣区域选取、模型封装及计算机软件系统绘制,获得三维扫描相关数据;将这些数据与传统软尺测量的周径、长度进行比较,同时与目前常用“水置换法”体积测量结果对比分析,以进一步验证三维扫描测量结果的准确性。结果:周径测量结果显示,软尺测量组与三维扫描组的腕围测量[(16.13 ± 1.50) cm vs (16.25 ± 1.77) cm, P > 0.05]、肘围[(25.10 ± 2.63) cm vs (25.91 ± 2.73) cm, P > 0.05]结果无差异;长度测量结果中,两组[(30.10 ± 1.69) cm vs (30.15 ± 1.92) cm, P > 0.05]有99.8%的一致性;体积测量两组[(1206.01 ± 306.94) cm3 vs (1224.54 ± 300.09) cm3, P > 0.05]结果无差异。结论:三维成像扫描方法具有操作简单、非接触式测量及可任意选取测量部位等特点,在肢体周径、长度及体积方面与传统测量结果相当。
Abstract: Objective: To quantitatively evaluate the practicality, simplicity, and accuracy of 3D imaging scanning methods for measuring the circumference, length, and volume of the human upper limb, and to compare and analyze these results with traditional measurement methods. Method: Prospectively, 31 subjects were included in the study for upper limb dimension analysis. A 3D scanning system was used to scan the upper limb dimensions, select regions of interest, encapsulate the model, and generate data through computer software. These data were then compared with traditional tape measurements of circumference and length, as well as with the commonly used “water displacement method” for volume measurement, to further validate the accuracy of the 3D scanning measurements. Results: The measurement results showed no significant differences between the tape measurement group and the 3D scanning group in terms of wrist circumference [(16.13 ± 1.50) cm vs (16.25 ± 1.77) cm, P > 0.05] or elbow circumference [(25.10 ± 2.63) cm vs (25.91 ± 2.73) cm, P > 0.05]. The length measurements between the two groups [(30.10 ± 1.69) cm vs (30.15 ± 1.92) cm, P > 0.05] were 99.8% consistent, with higher precision. Additionally, there was no significant difference in volume measurements between the two groups [(1206.01 ± 306.94) cm3 vs (1224.54 ± 300.09) cm3, P > 0.05]. Conclusion: The 3D imaging scanning method is characterized by its simplicity of operation, non-contact measurement, and the ability to select any measurement site. It is comparable to traditional measurement methods in terms of limb circumference, length, and volume.
文章引用:李鹏, 孙义, 毋荣, 孙剑端, 刘雯雯, 张雯, 乔霞霞, 李霁锋, 王龙虎. 三维成像扫描在上肢尺寸测量中的 应用研究[J]. 临床医学进展, 2026, 16(4): 4728-4734. https://doi.org/10.12677/acm.2026.1641744

参考文献

[1] Tur, J.A. and Bibiloni, M.D.M. (2019) Anthropometry, Body Composition and Resting Energy Expenditure in Human. Nutrients, 11, Article 1891. [Google Scholar] [CrossRef] [PubMed]
[2] Battraw, M.A., Fitzgerald, J., Joiner, W.M., James, M.A., Bagley, A.M. and Schofield, J.S. (2022) A Review of Upper Limb Pediatric Prostheses and Perspectives on Future Advancements. Prosthetics & Orthotics International, 46, 267-273. [Google Scholar] [CrossRef] [PubMed]
[3] Yau, L.K., Henry, F., Man Hong, C., Amy, C., Wai Kwan Vincent, C., Ping Keung, C., et al. (2022) Swelling Assessment after Total Knee Arthroplasty. Journal of Orthopaedic Surgery, 30, 1-10. [Google Scholar] [CrossRef] [PubMed]
[4] Farina, G., Galli, M., Borsari, L., Aliverti, A., Paraskevopoulos, I.T. and LoMauro, A. (2024) Limb Volume Measurements: A Comparison of Circumferential Techniques and Optoelectronic Systems against Water Displacement. Bioengineering, 11, Article 382. [Google Scholar] [CrossRef] [PubMed]
[5] Man, I.O.W., Markland, K.L. and Morrissey, M.C. (2010) The Validity and Reliability of the Perometer in Evaluating Human Knee Volume. Clinical Physiology and Functional Imaging, 24, 352-358. [Google Scholar] [CrossRef] [PubMed]
[6] Hirata, K., Ito, M., Nomura, Y., Kawashima, C., Tsuchiya, Y., Ooba, K., et al. (2022) Muscle Quality Indices Separately Associate with Joint-Level Power-Related Measures of the Knee Extensors in Older Males. European Journal of Applied Physiology, 122, 2271-2281. [Google Scholar] [CrossRef] [PubMed]
[7] Fenech, M. and Jaffrin, M.Y. (2004) Extracellular and Intracellular Volume Variations during Postural Change Measured by Segmental and Wrist-Ankle Bioimpedance Spectroscopy. IEEE Transactions on Biomedical Engineering, 51, 166-175. [Google Scholar] [CrossRef] [PubMed]
[8] Wu, X., Niu, Z., Xu, Z., Jiang, Y., Zhang, Y., Meng, H., et al. (2021) Fetal Weight Estimation by Automated Three-Dimensional Limb Volume Model in Late Third Trimester Compared to Two-Dimensional Model: A Cross-Sectional Prospective Observational Study. BMC Pregnancy and Childbirth, 21, Article No. 365. [Google Scholar] [CrossRef] [PubMed]
[9] Yang, J.C., Wu, S., Wang, Y., Luo, S., Kuo, S.C., Chien, P., et al. (2022) Effect of Lymphaticovenous Anastomosis on Muscle Edema, Limb, and Subfascial Volume in Lower Limb Lymphedema: MRI Studies. Journal of the American College of Surgeons, 235, 227-239. [Google Scholar] [CrossRef] [PubMed]
[10] White, B.N., Lu, I.M., Kao, L.S., Dixon, J.B., Weiler, M.J., Frank, N.D., et al. (2020) An Infrared 3D Scanning Device as a Novel Limb Volume Measurement Tool in Breast Cancer Patients. World Journal of Surgical Oncology, 18, Article No. 278. [Google Scholar] [CrossRef] [PubMed]
[11] Gallardo, Y.N.R., Salazar-Gamarra, R., Bohner, L., De Oliveira, J.I., Dib, L.L. and Sesma, N. (2023) Evaluation of the 3D Error of 2 Face-Scanning Systems: An in Vitro Analysis. The Journal of Prosthetic Dentistry, 129, 630-636. [Google Scholar] [CrossRef] [PubMed]
[12] White, B.N., Okoli, J., Dixon, J.B., Yuan, L., Yang, S. and Gabram-Mendola, S.G.A. (2021) Use of a Portable Infrared 3D Scanning Device Measuring Limb Volume in a Safety Net Hospital Breast Clinic. The Breast Journal, 27, 559-561. [Google Scholar] [CrossRef] [PubMed]
[13] Kudzia, P., Jackson, E. and Dumas, G. (2022) Estimating Body Segment Parameters from Three-Dimensional Human Body Scans. PLOS ONE, 17, e0262296. [Google Scholar] [CrossRef] [PubMed]
[14] Ashby, J., Lewis, M., Sunderland, C., Barrett, L.A. and Morris, J.G. (2023) The Reliability and Validity of a Portable Three-Dimensional Scanning System to Measure Leg Volume. Sensors, 23, Article 9177. [Google Scholar] [CrossRef] [PubMed]
[15] Taniguchi, M., Hirono, T., Nakayama, T., Kobayashi, K. and Ichihashi, N. (2021) Assessment of Edematous Changes Using Three-Dimensional Body Scanning and Segmental-Bioelectrical Impedance Spectroscopy. Lymphatic Research and Biology, 19, 524-530. [Google Scholar] [CrossRef] [PubMed]
[16] Cerqueira, M.S., Santos Borges, L., dos Santos Rocha, J.A., Brito Andrade, H., Silva Pirôpo, U., Lupato Conrado, L.A., et al. (2015) Twelve Hours of a Compression Sleeve Is Not Enough to Improve the Muscle Recovery of an Exercise-Damaged Upper Arm. Apunts. Medicina de lEsport, 50, 23-28. [Google Scholar] [CrossRef
[17] Tan, C., Coutts, F. and Bulley, C. (2013) Measurement of Lower Limb Volume: Agreement between the Vertically Oriented Perometer and a Tape Measure Method. Physiotherapy, 99, 247-251. [Google Scholar] [CrossRef] [PubMed]
[18] Edmond, T., Laps, A., Case, A.L., O’Hara, N. and Abzug, J.M. (2020) Normal Ranges of Upper Extremity Length, Circumference, and Rate of Growth in the Pediatric Population. HAND, 15, 713-721. [Google Scholar] [CrossRef] [PubMed]
[19] Oza, C., Pargaonkar, Y., Dunna, D., Gondhalekar, K., Khadilkar, V. and Khadilkar, A. (2022) Validation of Mid-Upper-Arm-Circumference Cut-Offs for Assessment of Overnutrition in Indian Children and Adolescents with Type 1 Diabetes. Primary Care Diabetes, 16, 466-470. [Google Scholar] [CrossRef] [PubMed]
[20] Llanos, C., Gan, E.Y., Chen, J., Lee, M.J., Kilbreath, S.L. and Dylke, E.S. (2020) Reliability and Validity of Physical Tools and Measurement Methods to Quantify Hand Swelling: A Systematic Review. Physical Therapy, 101, pzaa206.
[21] Houwen, F., Stemkens, J., de Schipper, P.J., van der Wouw, P., Heitink, M. and van Langen, H. (2022) Estimates for Assessment of Lymphedema: Reliability and Validity of Extremity Measurements. Lymphatic Research and Biology, 20, 48-52. [Google Scholar] [CrossRef] [PubMed]
[22] Retrouvey, H., Chan, J. and Shahrokhi, S. (2018) Comparison of Two-Dimensional Methods versus Three-Dimensional Scanning Systems in the Assessment of Total Body Surface Area Estimation in Burn Patients. Burns, 44, 195-200. [Google Scholar] [CrossRef] [PubMed]
[23] Powers, O.A., Palmer, J.R. and Wilken, J.M. (2022) Reliability and Validity of 3D Limb Scanning for Ankle-Foot Orthosis Fitting. Prosthetics & Orthotics International, 46, 84-90. [Google Scholar] [CrossRef] [PubMed]
[24] Zhao, M., Kawahara, J., Abhishek, K., Shamanian, S. and Hamarneh, G. (2022) Skin3D: Detection and Longitudinal Tracking of Pigmented Skin Lesions in 3D Total-Body Textured Meshes. Medical Image Analysis, 77, Article 102329. [Google Scholar] [CrossRef] [PubMed]
[25] Varallo, A., Sarno, A., Castriconi, R., Mazzilli, A., Loria, A., del Vecchio, A., et al. (2022) Fabrication of 3D Printed Patient-Derived Anthropomorphic Breast Phantoms for Mammography and Digital Breast Tomosynthesis: Imaging Assessment with Clinical X-Ray Spectra. Physica Medica, 98, 88-97. [Google Scholar] [CrossRef] [PubMed]