基于纳米材料的比色侧向层析试纸条信号放大策略
Signal Amplification Strategies for Colorimetric Lateral Flow Assay Based on Nanomaterials
摘要: 比色侧向层析测定(Colorimetric Lateral Flow Assay, CLFA)因具有操作简便、检测快速、成本低廉及无需复杂仪器等优势,已广泛应用于疾病诊断、食品安全和环境监测等现场即时检测领域。然而,传统基于胶体金纳米颗粒(AuNPs)的CLFA受限于信号强度不足,难以满足痕量分析物和早期生物标志物检测的需求。近年来,基于纳米材料的信号放大策略为提升CLFA灵敏度提供了重要途径。其中,一方面可通过优化AuNPs的尺寸、聚集状态及载体负载方式增强局域表面等离子体共振效应;另一方面,可利用具有类酶催化活性的纳米酶催化显色底物,实现高效信号放大。本文系统综述了近年来纳米材料增强CLFA的主要研究进展,重点介绍了AuNPs尺寸调控、聚集增强及载体负载策略,并进一步总结了贵金属纳米酶、金属有机框架(MOF)基纳米酶、金属氧化物纳米酶及其他复合纳米酶在催化放大中的应用特点与机制。同时,对不同类型纳米酶的性能差异、适用场景及发展潜力进行了综合比较。最后,对高灵敏度、低成本、多功能一体化CLFA的发展趋势及其临床转化前景进行了展望。
Abstract: Colorimetric lateral flow assay (CLFA) has been widely applied in point-of-care testing owing to its simplicity, rapid response, low cost, and instrument-free operation. However, conventional colloidal gold nanoparticle (AuNP)-based CLFA suffers from insufficient signal intensity, which limits its applicability in trace-level analyte detection and early disease diagnosis. In recent years, nanomaterial-based signal amplification strategies have provided effective approaches to improve the sensitivity of CLFA. On one hand, the localized surface plasmon resonance effect can be enhanced through optimization of AuNP size, aggregation state, and carrier loading strategies. On the other hand, nanozymes with enzyme-like catalytic activities can catalyze chromogenic substrates to achieve significant signal amplification. This review systematically summarizes recent advances in nanomaterial-enhanced CLFA, with emphasis on AuNP size regulation, aggregation amplification, and carrier-assisted strategies. Furthermore, the catalytic mechanisms and application characteristics of noble metal nanozymes, metal-organic framework (MOF)-based nanozymes, metal oxide nanozymes, and other composite nanozymes are comprehensively discussed. Comparative analyses of different nanozyme systems in terms of catalytic performance, cost, stability, and application scenarios are also presented. Finally, the future perspectives of highly sensitive, low-cost, and multifunctionally integrated CLFA platforms for clinical and on-site applications are discussed.
文章引用:宋娜娜, 王晓琨. 基于纳米材料的比色侧向层析试纸条信号放大策略[J]. 材料化学前沿, 2026, 14(3): 311-330. https://doi.org/10.12677/amc.2026.143031

参考文献

[1] Liu, Y., Zhan, L., Qin, Z., Sackrison, J. and Bischof, J.C. (2021) Ultrasensitive and Highly Specific Lateral Flow Assays for Point-of-Care Diagnosis. ACS Nano, 15, 3593-3611. [Google Scholar] [CrossRef] [PubMed]
[2] 顾佳钰, 胡馨儿, 王晓飞, 等. 侧流免疫层析定量检测方法的研究进展[J]. 药学实践与服务, 2024, 42(7): 273-277+284.
[3] Joung, Y., Han, D.K., Jang, H., Kang, T., Chen, L. and Choo, J. (2025) Dual-Pathway Lateral Flow Assay for Rapid and Sensitive SARS-CoV-2 RNA Detection via CRISPR/Cas13a-Mediated SERS. ACS Sensors, 10, 6253-6262. [Google Scholar] [CrossRef] [PubMed]
[4] 闫灵芝. 侧流免疫层析技术在食品安全检测中的研究进展[J]. 食品工业科技, 2022, 43(4): 1-11.
[5] Ye, H. and Xia, X. (2018) Enhancing the Sensitivity of Colorimetric Lateral Flow Assay (CLFA) through Signal Amplification Techniques. Journal of Materials Chemistry B, 6, 7102-7111. [Google Scholar] [CrossRef] [PubMed]
[6] Renzi, E., Piper, A., Nastri, F., Merkoçi, A. and Lombardi, A. (2023) An Artificial Miniaturized Peroxidase for Signal Amplification in Lateral Flow Immunoassays. Small, 19, Article ID: 2207949. [Google Scholar] [CrossRef] [PubMed]
[7] 闫灵芝. 免疫层析试纸条信号放大技术研究进展[J]. 食品工业科技, 2022, 43(11): 34-44.
[8] Moon, Y., Cho, H.H., Moon, H., Song, H., Ro, J.C., Lee, J.H., et al. (2024) Simultaneous Triplex Detection in a Single-Test-Line Lateral Flow Immunoassay Utilizing Distinct Nanoparticle Colorimetry. BioChip Journal, 18, 247-256. [Google Scholar] [CrossRef
[9] 朱青萌, 陈燕. 纳米酶: 对天然酶的“模拟”和“超越” [J]. 化学教育(中英文), 2025, 46(14): 1-7.
[10] 余安安, 王宏赏, 陈洪宇. 双金属纳米酶的酶模拟催化活性和生物医学应用研究进展[J]. 分子催化(中英文), 2026, 40(1): 83-96.
[11] Song, J., Xu, C., Zeng, S., Zuo, W., Yang, Q., Hu, Q., et al. (2025) Metal Ion-Based Chemical Coordination Amplification: A Chromophore in Situ Deposition Strategy for Visual Sensitivity-Enhanced Lateral Flow Immunochromatography Assays. Analytical Chemistry, 97, 3477-3485. [Google Scholar] [CrossRef] [PubMed]
[12] 董旭旭, 孙威, 曹攀, 等. 胶体金免疫层析试纸条技术在病毒检测领域的应用研究现状[J]. 生物工程学报, 2022, 38(9): 3243-3254.
[13] Lou, S., Ye, J.Y., Li, K.Q. and Wu, A. (2012) A Gold Nanoparticle-Based Immunochromatographic Assay: The Influence of Nanoparticulate Size. The Analyst, 137, 1174-1181. [Google Scholar] [CrossRef] [PubMed]
[14] Kim, D., Kim, Y., Hong, S., Kim, J., Heo, N., Lee, M., et al. (2016) Development of Lateral Flow Assay Based on Size-Controlled Gold Nanoparticles for Detection of Hepatitis B Surface Antigen. Sensors, 16, Article No. 2154. [Google Scholar] [CrossRef] [PubMed]
[15] Song, E., Kim, I., Jeon, C. and Pyun, S. (2023) Development and Optimization of Surface-Enhancement Raman Scattering-Based Lateral Flow Immunoassays for the Ultrasensitive Detection of Cardiac Troponin I. Microchemical Journal, 193, Article ID: 108962. [Google Scholar] [CrossRef
[16] Shen, Y. and Shen, G. (2019) Signal-Enhanced Lateral Flow Immunoassay with Dual Gold Nanoparticle Conjugates for the Detection of Hepatitis B Surface Antigen. ACS Omega, 4, 5083-5087. [Google Scholar] [CrossRef
[17] Choi, D.H., Lee, S.K., Oh, Y.K., Bae, B.W., Lee, S.D., Kim, S., et al. (2010) A Dual Gold Nanoparticle Conjugate-Based Lateral Flow Assay (LFA) Method for the Analysis of Troponin I. Biosensors and Bioelectronics, 25, 1999-2002. [Google Scholar] [CrossRef] [PubMed]
[18] Ma, L.H., Wang, H.B., Zhang, T., Xuan, Y., Li, C., Chen, W., et al. (2019) Visual Simultaneous Detection of Single Nucleotide Polymorphism of Tumor Susceptibility Gene and Marker Alpha-Fetoprotein Based on Double-Labeled Colloidal Gold Probe with Lateral Flow Strip Biosensor. Sensors and Actuators B: Chemical, 298, Article ID: 126819. [Google Scholar] [CrossRef
[19] Hu, J., Wang, L., Li, F., Han, Y.L., Lin, M., Lu, T.J., et al. (2013) Oligonucleotide-Linked Gold Nanoparticle Aggregates for Enhanced Sensitivity in Lateral Flow Assays. Lab on a Chip, 13, 4352-4357. [Google Scholar] [CrossRef] [PubMed]
[20] Xu, H., Chen, J., Birrenkott, J., Zhao, J.X., Takalkar, S., Baryeh, K., et al. (2014) Gold-Nanoparticle-Decorated Silica Nanorods for Sensitive Visual Detection of Proteins. Analytical Chemistry, 86, 7351-7359. [Google Scholar] [CrossRef] [PubMed]
[21] Liu, Y., Liu, D., Cui, S., Li, C., Yun, Z., Zhang, J., et al. (2022) Design of a Signal-Amplified Aptamer-Based Lateral Flow Test Strip for the Rapid Detection of Ochratoxin a in Red Wine. Foods, 11, Article No. 1598. [Google Scholar] [CrossRef] [PubMed]
[22] Liu, X., Yang, J., Li, Q., Wang, Y., Wang, Y., Li, G., et al. (2020) A Strip Test for the Optical Determination of Influenza Virus H3 Subtype Using Gold Nanoparticle Coated Polystyrene Latex Microspheres. Microchimica Acta, 187, 1-7. [Google Scholar] [CrossRef] [PubMed]
[23] Huang, Q., Bu, T., Zhang, W., Yan, L., Zhang, M., Yang, Q., et al. (2018) An Improved Clenbuterol Detection by Immunochromatographic Assay with Bacteria@au Composite as Signal Amplifier. Food Chemistry, 262, 48-55. [Google Scholar] [CrossRef] [PubMed]
[24] Koczula, K.M. and Gallotta, A. (2016) Lateral Flow Assays. Essays in Biochemistry, 60, 111-120. [Google Scholar] [CrossRef] [PubMed]
[25] Calabria, D., Calabretta, M.M., Zangheri, M., Marchegiani, E., Trozzi, I., Guardigli, M., et al. (2021) Recent Advancements in Enzyme-Based Lateral Flow Immunoassays. Sensors, 21, Article No. 3358. [Google Scholar] [CrossRef] [PubMed]
[26] Scarsi, A., Pedone, D. and Pompa, P.P. (2023) A Multi-Line Platinum Nanozyme-Based Lateral Flow Device for the Colorimetric Evaluation of Total Antioxidant Capacity in Different Matrices. Nanoscale Advances, 5, 2167-2174. [Google Scholar] [CrossRef] [PubMed]
[27] Pedone, D., Moglianetti, M., Lettieri, M., Marrazza, G. and Pompa, P.P. (2020) Platinum Nanozyme-Enabled Colorimetric Determination of Total Antioxidant Level in Saliva. Analytical Chemistry, 92, 8660-8664. [Google Scholar] [CrossRef] [PubMed]
[28] Cai, X., Luo, Y., Zhu, C., Huang, D. and Song, Y. (2022) Rhodium Nanocatalyst-Based Lateral Flow Immunoassay for Sensitive Detection of Staphylococcal Enterotoxin B. Sensors and Actuators B: Chemical, 367, Article ID: 132066. [Google Scholar] [CrossRef
[29] Wei, D., Zhang, X., Chen, B. and Zeng, K. (2020) Using Bimetallic Au@Pt Nanozymes as a Visual Tag and as an Enzyme Mimic in Enhanced Sensitive Lateral-Flow Immunoassays: Application for the Detection of Streptomycin. Analytica Chimica Acta, 1126, 106-113. [Google Scholar] [CrossRef] [PubMed]
[30] Jin, X., Chen, L., Zhang, Y., Wang, X. and Zhou, N. (2021) A Lateral Flow Strip for On-Site Detection of Tobramycin Based on Dual-Functional Platinum-Decorated Gold Nanoparticles. The Analyst, 146, 3608-3616. [Google Scholar] [CrossRef] [PubMed]
[31] Bai, T., Wang, L., Wang, M., Zhu, Y., Li, W., Guo, Z., et al. (2022) Strategic Synthesis of Trimetallic Au@Ag-Pt Nanorattles for Ultrasensitive Colorimetric Detection in Lateral Flow Immunoassay. Biosensors and Bioelectronics, 208, Article ID: 114218. [Google Scholar] [CrossRef] [PubMed]
[32] Sun, Y., Xie, Z., Pei, F., Hu, W., Feng, S., Hao, Q., et al. (2022) Trimetallic Au@Ag-Pt Nanozyme-Enhanced Lateral Flow Immunoassay for the Detection of SARS-CoV-2 Nucleocapsid Protein. Analytical Methods, 14, 5091-5099. [Google Scholar] [CrossRef] [PubMed]
[33] Meng, X., Zuo, W., Wu, P., Song, Y., Yang, G., Zhang, S., et al. (2024) Bimetallic Nanozyme: A Credible Tag for in Situ-Catalyzed Reporter Deposition in the Lateral Flow Immunoassay for Ultrasensitive Cancer Diagnosis. Nano Letters, 24, 51-60. [Google Scholar] [CrossRef] [PubMed]
[34] Wang, Z., Zou, R., Yi, J., Wang, Y., Hu, H., Qi, C., et al. (2024) “Four-in-One” Multifunctional Dandelion‐Like Gold@platinum Nanoparticles‐Driven Multimodal Lateral Flow Immunoassay. Small, 20, Article ID: 2310869. [Google Scholar] [CrossRef] [PubMed]
[35] Wei, Z., Luciano, K. and Xia, X.H. (2022) Catalytic Gold-Iridium Nanoparticles as Labels for Sensitive Colorimetric Lateral Flow Assay. ACS Nano, 16, 21609-21617. [Google Scholar] [CrossRef] [PubMed]
[36] Liu, S., Dou, L., Yao, X., Zhang, W., Zhao, M., Yin, X., et al. (2020) Nanozyme Amplification Mediated On-Demand Multiplex Lateral Flow Immunoassay with Dual-Readout and Broadened Detection Range. Biosensors and Bioelectronics, 169, Article ID: 112610. [Google Scholar] [CrossRef] [PubMed]
[37] Wang, D., Wang, J., Liu, D., He, J., Wang, M., Huang, H., et al. (2023) Rapid and Sensitive Detection of Epstein-Barr Virus Antibodies in Nasopharyngeal Carcinoma by Chemiluminescence Strips Based on Iron-Porphyrin Single Atom Nanozyme. Nano Research, 17, 1827-1836. [Google Scholar] [CrossRef
[38] Li, X., Li, G., Pan, Q., Xue, F., Wang, Z. and Peng, C. (2024) Rapid and Ultra-Sensitive Lateral Flow Assay for Pathogens Based on Multivalent Aptamer and Magnetic Nanozyme. Biosensors and Bioelectronics, 250, Article ID: 116044. [Google Scholar] [CrossRef] [PubMed]
[39] Chen, R., Chen, X., Zhou, Y., Lin, T., Leng, Y., Huang, X., et al. (2022) “Three-in-One” Multifunctional Nanohybrids with Colorimetric Magnetic Catalytic Activities to Enhance Immunochromatographic Diagnosis. ACS Nano, 16, 3351-3361. [Google Scholar] [CrossRef] [PubMed]
[40] Nguyen, P.T., Lee, J., Cho, A., Kim, M.S., Choi, D., Han, J.W., et al. (2022) Rational Development of Co‐Doped Mesoporous Ceria with High Peroxidase‐Mimicking Activity at Neutral Ph for Paper‐Based Colorimetric Detection of Multiple Biomarkers. Advanced Functional Materials, 32, Article ID: 2112428. [Google Scholar] [CrossRef
[41] Dong, T., Zhang, X., Yuan, J., Lin, Z., Yin, P., Yu, H., et al. (2023) Sensitive Lateral Flow Immunoassay Based on Specific Peptide and Superior Oxidase Mimics with a Universal Dual-Mode Significant Signal Amplification. Analytical Chemistry, 95, 12532-12540. [Google Scholar] [CrossRef] [PubMed]
[42] Cai, X., Liang, M., Ma, F., Zhang, Z., Tang, X., Jiang, J., et al. (2022) Nanozyme-Strip Based on MnO2 Nanosheets as a Catalytic Label for Multi-Scale Detection of Aflatoxin B1 with an Ultrabroad Working Range. Food Chemistry, 377, Article ID: 131965. [Google Scholar] [CrossRef] [PubMed]
[43] Ouyang, H., Lu, Q., Wang, W., Song, Y., Tu, X., Zhu, C., et al. (2018) Dual-Readout Immunochromatographic Assay by Utilizing MnO2 Nanoflowers as the Unique Colorimetric/Chemiluminescent Probe. Analytical Chemistry, 90, 5147-5152. [Google Scholar] [CrossRef] [PubMed]
[44] Wang, B., Moyano, A., Duque, J.M., Sánchez, L., García-Santos, G., Flórez, L.J.G., et al. (2022) Nanozyme-Based Lateral Flow Immunoassay (LFIA) for Extracellular Vesicle Detection. Biosensors, 12, Article No. 490. [Google Scholar] [CrossRef] [PubMed]
[45] Dou, L., Bai, Y., Liu, M., Shao, S., Yang, H., Yu, X., et al. (2022) “Three-to-One” Multi-Functional Nanocomposite-Based Lateral Flow Immunoassay for Label-Free and Dual-Readout Detection of Pathogenic Bacteria. Biosensors and Bioelectronics, 204, Article ID: 114093. [Google Scholar] [CrossRef] [PubMed]
[46] Hong, J., Guo, Z., Duan, D., et al. (2024) Highly Sensitive Nanozyme Strip: An Effective Tool for Forensic Material Evidence Identification. Nano Research, 17, 1785-1791.
[47] Wang, Y., Feng, Q., Yan, H., Sun, R., Cao, Y., Wu, H., et al. (2024) Trifunctional Nanocomposites with Colorimetric Magnetic Catalytic Activities Labels in Sandwich Immunochromatographic Detection of Escherichia coli O157:H7. Analytical Chemistry, 96, 1232-1240. [Google Scholar] [CrossRef] [PubMed]
[48] Yang, D., Wang, L., Jia, T., Lian, T., Yang, K., Li, X., et al. (2023) Au/Fe3O4-Based Nanozymes with Peroxidase-Like Activity Integrated in Immunochromatographic Strips for Highly-Sensitive Biomarker Detection. Analytical Methods, 15, 663-674. [Google Scholar] [CrossRef] [PubMed]
[49] Yang, D., Lei, L., Yang, K., Gao, K., Jia, T., Wang, L., et al. (2022) An Immunochromatography Strip with Peroxidase-Mimicking Ferric Oxyhydroxide Nanorods-Mediated Signal Amplification and Readout. Microchimica Acta, 189, 1-11. [Google Scholar] [CrossRef] [PubMed]
[50] Chen, Y., Ren, J., Yin, X., Li, Y., Shu, R., Wang, J., et al. (2022) Vanadium Disulfide Nanosheet Boosts Optical Signal Brightness as a Superior Enzyme Label to Improve the Sensitivity of Lateral Flow Immunoassay. Analytical Chemistry, 94, 8693-8703. [Google Scholar] [CrossRef] [PubMed]
[51] Zhu, X., Tang, J., Ouyang, X., Liao, Y., Feng, H., Yu, J., et al. (2024) A Versatile CuCo@PDA Nanozyme-Based Aptamer-Mediated Lateral Flow Assay for Highly Sensitive, On-Site and Dual-Readout Detection of Aflatoxin B1. Journal of Hazardous Materials, 465, Article ID: 133178. [Google Scholar] [CrossRef] [PubMed]
[52] Song, Y., Cai, X., Ostermeyer, G., Yu, J., Du, D. and Lin, Y. (2021) Self-Assembling Allochroic Nanocatalyst for Improving Nanozyme-Based Immunochromatographic Assays. ACS Sensors, 6, 220-228. [Google Scholar] [CrossRef] [PubMed]