空心绝缘管注射后缩短原因分析
The Reason Study of Insulating Hollow Tube Shortening after Injection
摘要:
复合绝缘管在注射后长度出现缩短现象。其主要原因包括以下三个方面:固化程度不完全、绝缘管内应力未完全释放、环境湿度大导致固化剂甲基四氢苯酐水解;且外,本文对绝缘管注射后缩短给出了有效的解决方案。
Abstract: The reasons for the contraction of the tube after injection are as follows: incomplete curing degree, not-fully-released internal stress of the tube, and MTHPA hydrolysis because of the environmental humidity. Furthermore, this paper gives effective solutions for the above problem.
参考文献
|
[1]
|
马斌 (2003) 复合空心绝缘子产品及制造技术. 变压器, 8, 35-38.
|
|
[2]
|
陈平, 刘胜平, 王德中 (2011) 环氧树脂及其应用. 化学工业出版社, 北京.
|
|
[3]
|
M. Shimbo, M. Ochi, Y. Shigeta, 高炳华 (1986) 环氧树脂在固化过程中的收缩与内应力. 绝缘材料通讯, 4, 42- 46.
|