空心绝缘管注射后缩短原因分析
The Reason Study of Insulating Hollow Tube Shortening after Injection
摘要: 复合绝缘管在注射后长度出现缩短现象。其主要原因包括以下三个方面:固化程度不完全、绝缘管内应力未完全释放、环境湿度大导致固化剂甲基四氢苯酐水解;且外,本文对绝缘管注射后缩短给出了有效的解决方案。
Abstract: The reasons for the contraction of the tube after injection are as follows: incomplete curing degree, not-fully-released internal stress of the tube, and MTHPA hydrolysis because of the environmental humidity. Furthermore, this paper gives effective solutions for the above problem.
文章引用:潘彩红, 丁建兵, 宋波, 于晓蕾, 陈小娟, 汪强. 空心绝缘管注射后缩短原因分析[J]. 材料科学, 2015, 5(3): 85-87. https://dx.doi.org/10.12677/MS.2015.53012

参考文献

[1] 马斌 (2003) 复合空心绝缘子产品及制造技术. 变压器, 8, 35-38.
[2] 陈平, 刘胜平, 王德中 (2011) 环氧树脂及其应用. 化学工业出版社, 北京.
[3] M. Shimbo, M. Ochi, Y. Shigeta, 高炳华 (1986) 环氧树脂在固化过程中的收缩与内应力. 绝缘材料通讯, 4, 42- 46.