带金属保护层管道缺陷的脉冲涡流响应仿真分析
Simulation Analysis of Pulsed Eddy Current Responses to Defects in Pipelines with Metallic Protective Layers
摘要: 管道作为储运系统的关键承压部件,一旦因局部腐蚀、机械损伤或壁厚减薄发生失效,可能引起低温介质泄漏,并产生各类次生风险。脉冲涡流无损检测技术具有极佳的穿透能力,对于管道外部包覆结构带来的缺陷检测难度有很好的针对性。本文针对带金属保护层管道的缺陷检测问题,建立脉冲涡流有限元模型,以有缺陷与无缺陷工况下接收线圈电压的差值作为分析信号,研究内、外表面缺陷宽度、深度及传感器提离高度对差分电压特征的影响。仿真结果表明,在所研究的参数范围内,差分电压峰值随缺陷宽度和深度增大而增大;相同缺陷尺寸下,外表面缺陷的峰值高于内表面缺陷;随着提离高度增大,峰值总体减小。研究表明,差分电压峰值能够反映缺陷几何参数的变化,为带金属保护层管道的脉冲涡流缺陷分析及特征选取提供了仿真参考。
Abstract: As critical pressure-bearing components in storage and transportation systems, pipelines may fail due to localized corrosion, mechanical damage, or wall thinning, potentially resulting in the leakage of cryogenic fluids and various secondary hazards. Pulsed eddy current (PEC) nondestructive testing technology exhibits excellent penetration capability, making it particularly suitable for detecting defects in pipelines with external protective layers. To address the challenges associated with defect detection in pipelines with metallic protective layers, a finite element model of pulsed eddy current testing is established in this study. The voltage difference between the receiving coil signals under defective and defect-free conditions is used as the analytical signal. The effects of defect width, defect depth, and sensor lift-off distance on the differential voltage characteristics are investigated for defects located on both the inner and outer surfaces of the pipeline. The simulation results indicate that, within the investigated parameter ranges, the peak differential voltage increases with increasing defect width and depth. For defects of identical dimensions, those located on the outer surface produce higher peak values than those on the inner surface. Furthermore, the peak differential voltage generally decreases as the sensor lift-off distance increases. The results demonstrate that the peak differential voltage can effectively reflect variations in defect geometric parameters, providing a simulation-based reference for defect characterization and feature selection in pulsed eddy current testing of pipelines with metallic protective layers.
参考文献
|
[1]
|
Sophian, A., Tian, G. and Fan, M. (2017) Pulsed Eddy Current Non-Destructive Testing and Evaluation: A Review. Chinese Journal of Mechanical Engineering, 30, 500-514. https://doi.org/10.1007/s10033-017-0122-4
|
|
[2]
|
Yu, X., Zhu, Y., Cao, Y. and Xiong, J. (2023) Time-Domain Numerical Simulation and Experimental Study on Pulsed Eddy Current Inspection of Tubing and Casing. Sensors, 23, Article 1135. https://doi.org/10.3390/s23031135
|
|
[3]
|
Nafiah, F., Sophian, A., Khan, M.R. and Zainal Abidin, I.M. (2019) Quantitative Evaluation of Crack Depths and Angles for Pulsed Eddy Current Non-Destructive Testing. NDT & E International, 102, 180-188. https://doi.org/10.1016/j.ndteint.2018.11.019
|
|
[4]
|
Fu, Y., Lei, M., Li, Z., Gu, Z., Yang, H., Cao, A., et al. (2017) Lift-Off Effect Reduction Based on the Dynamic Trajectories of the Received-Signal Fast Fourier Transform in Pulsed Eddy Current Testing. NDT & E International, 87, 85-92. https://doi.org/10.1016/j.ndteint.2017.01.010
|
|
[5]
|
Wang, H., Huang, J., Liu, L., Qin, S. and Fu, Z. (2022) A Novel Pulsed Eddy Current Criterion for Non-Ferromagnetic Metal Thickness Quantifications under Large Liftoff. Sensors, 22, Article 614. https://doi.org/10.3390/s22020614
|
|
[6]
|
Dodd, C.V. and Deeds, W.E. (1968) Analytical Solutions to Eddy-Current Probe-Coil Problems. Journal of Applied Physics, 39, 2829-2838. https://doi.org/10.1063/1.1656680
|
|
[7]
|
Theodoulidis, T. and Kriezis, E. (2005) Series Expansions in Eddy Current Nondestructive Evaluation Models. Journal of Materials Processing Technology, 161, 343-347. https://doi.org/10.1016/j.jmatprotec.2004.07.048
|
|
[8]
|
Desjardins, D., Krause, T.W. and Clapham, L. (2015) Transient Response of a Driver-Pickup Coil Probe in Transient Eddy Current Testing. NDT & E International, 75, 8-14. https://doi.org/10.1016/j.ndteint.2015.04.008
|