电网线路雷击跳闸占整个电网的跳闸总数的70%~80%以上。减少雷击跳闸事故一方面需要安装相应的防雷保护装置,另一方面要降低接地电阻。传统的镀锌角钢接地网具有易腐蚀、施工工程量大、占地多、易产生施工纠纷、易受客观因素影响,寿命不满足要求等缺点。柔性石墨复合接地材料具有导电性好、无毒、无污染,抗酸碱、抗腐蚀性能强,性能稳定,使用寿命长等特点。在信宜供电局配网的接地系统中使用表明,新型的接地材料能适应各种极端地质条件,并能够满足实际工程应用需求,值得推广应用。
Abstract:
Lightning trip of the power line accounts for 70% - 80% of the total trips of the entire power grid. To reduce the risk of lightning strikes, on the one hand, it is necessary to install corresponding lightning protection devices, and on the other hand, ground resistance must be reduced. The traditional galvanized angle steel grounding grid has the defects of easy corrosion, large amount of construction work, large area occupation, easy to produce construction disputes, easy to be affected by objective factors, and unsatisfactory life expectancy. Flexible graphite composite grounding material has good electrical conductivity, non-toxic, non-polluting, anti-acid and alkali, strong corrosion resistance, stable performance, and long service life. The application of the new grounding material in the grounding system of Xinyi Power Supply Bureau shows that the new type of grounding material can adapt to various extreme geological conditions and can meet the needs of practical engineering application and should be popularized and applied.
参考文献
|
[1]
|
王培军, 付学文, 魏智娟. 新型高效降阻接地模块的研究与应用[J]. 电磁避雷器, 2012(245): 70-76.
|
|
[2]
|
程学启, 杨春雷, 咸日常, 等. 线路避雷器在输电线路防雷中的应用[J]. 中国电力, 1999, 32(8): 33-35.
|
|
[3]
|
满超楠. 接地材料和防腐降阻材料的性能研究及其优化选择[D]. 长沙: 长沙理工大学, 2013.
|
|
[4]
|
苏邦礼, 崔秉球, 伍望平, 等. 雷电与避雷工程接地装置[M]. 广州: 中山大学出版社, 2011.
|
|
[5]
|
电力工业部. 《电力建设安全工作规程》(SDJ63-1982) [S]. 北京: 中国电力出版社, 2010: 7-8.
|
|
[6]
|
曾嵘, 周佩朋, 王森, 等. 接地系统中接触电阻的仿真模型及其影响因素分析[J]. 高电压技术, 2010, 36(10): 2393-2397.
|
|
[7]
|
郑敏聪, 李建华, 聂新辉, 等. 镀锌钢接地材料在酸性土壤中的腐蚀行为研究[J]. 中国腐蚀与防护学报, 2015(1): 27-32.
|
|
[8]
|
顾安妍. 膨胀石墨的制备及其导电性能的研究[D]. 重庆: 重庆大学, 2010.
|
|
[9]
|
胡元潮, 阮江军, 肖微, 等. 柔性石墨复合接地材料及其相关性能试验研究[J]. 高电压技术, 2015, 42(6): 1879-1889.
|
|
[10]
|
肖微, 胡元潮, 阮江军, 等. 柔性石墨复合接地材料及其接地特性[J]. 电工技术学报, 2017, 32(2): 85-94.
|
|
[11]
|
赵俊, 强宝仁. 输电线路接地网防盗措施的改进[J]. 电力学报, 2005, 19(3): 251-252.
|