蒸发换热器与变压器连接位置对流动换热的影响
The Influence of Connection Position between Evaporation Heat Exchanger and Transformer on Flow and Heat Exchange
DOI: 10.12677/SE.2018.82003, PDF,   
作者: 刘婷婷, 李永光:上海电力学院,能源与机械工程学院,上海
关键词: 地下变压器蒸发换热器模拟散热Underground Transformer Evaporative Heat Exchanger Simulation Heat Dissipation
摘要: 应用fluent软件对地下变压器和蒸发换热器模型进行模拟与分析,得出了变压器与蒸发换热器之间的油流特点以及周围空气的运动情况。对比分析不同连接位置的蒸发换热器的流场和温度场,得出了蒸发换热器位置靠上的位置的模型换热情况较好,以及流体在连接位置的流动速度最快的结论。
Abstract: The fluent software was used to simulate and analyze the underground transformer and evaporative heat exchanger model, and the characteristics of the oil flow between the transformer and the evaporative heat exchanger and the movement of the surrounding air were obtained. Comparing and analyzing the flow field and temperature field of evaporative heat exchangers at different connection positions, it is concluded that the heat transfer conditions of the evaporative heat exchanger are better and the flow velocity of the fluid at the connection position is the fastest.
文章引用:刘婷婷, 李永光. 蒸发换热器与变压器连接位置对流动换热的影响[J]. 可持续能源, 2018, 8(2): 23-31. https://doi.org/10.12677/SE.2018.82003

参考文献

[1] 姜益民. 城市电力变压器的发展趋势[J]. 变压器, 2005, 42(8): 1-4.
[2] 何永秀, 朱茳, 罗涛, 等. 城市电网规划自然灾害风险评价研究[J]. 电工技术学报, 2011, 26(12): 205-210.
[3] 卞辉, 姜益民, 袁聪波, 等. 强油油冷式冷却方式在城市地下变电站中的应用[J]. 变压器, 2011, 48(8): 43-47.
[4] 于海波. 关于地下变压器冷却系统的分析[J]. 通信电源技术, 2011, 28(6): 80-81.
[5] 成展鹏, 胡佐. 一起主变强油风冷回路不正常启动的分析[J]. 电力系统保护与控制, 2009, 37(5): 93-95.
[6] 祝丽花, 杨庆新, 闫荣, 等. 考虑磁致伸缩效应电力变压器振动噪声的研究[J]. 电工技术学报, 2013, 28(4): 1-6.
[7] 哈恩E, 格里占尔U. 沸腾换热[M]. 王兴国, 华诚生, 译. 北京: 国防工业出版社, 1988.