摘要: 对输配电网几种常用悬垂线夹、耐张线夹按照DL/T 1288-2013《电力金具能耗测试与节能技术评价要求》标准要求进行了能耗测试,依据能耗测试结果和节能技术评价准则确认XGU-4、XGU-5B悬垂线夹和NLD-4耐张线夹为非节能型金具,CGL-4和XGF-5X悬垂线夹为节能型金具,并且,节能型金具比非节能型金具的能耗值小很多,节能效果明显。
Abstract: Several common transmission and distribution grid suspension clamp, strain clamp are tested in accordance with the standard-DL/T 1288-2013 “Energy Consumption of Electric Power Fittings and Evaluation of Energy Saving Technology Requirements”. According to the energy consumption test results and energy saving technology criterion, XGU-4, XGU-5B suspension clamp and NLD-4 strain clamp are identified as non-energy saving fittings and, XGF-4, CGL-5X suspension clamp are identified as energy-saving fittings. The test results indicate that energy-saving fittings consume much less energy than the non-energy saving fittings, and energy saving effect is obvious.
文章引用:张雍斌, 吴斌, 李鑫. 输配电网几种常用金具的能耗测试与节能技术评价[J]. 输配电工程与技术, 2018, 7(2): 29-34. https://doi.org/10.12677/TDET.2018.72004

参考文献

[1] 能源部东北电力设计院. 电力工程高压送电线路设计手册[M]. 北京: 中国电力出版社. 1998.
[2] GB/T 2314-2008 电力金具通用技术条件[S]. 北京: 中国标准出版社, 2009.
[3] DL/T 756-2009 悬垂线夹[S]. 北京: 中国电力出版社, 2009.
[4] 程应镗. 送电线路金具的设计, 安装, 试验和应用[M]. 北京: 水利电力出版社, 1989.
[5] DL/T 1288-2013电力金具能耗测试与节能技术评价要求[S]. 北京: 中国电力出版社, 2013.