手掘式顶钢筋混凝土套管的设计与施工研究
Research on the Design and Construction of Hand Driven Reinforced Concrete Casings
摘要:
通过对手掘式顶管的设计、施工的关键点进行了说明,着重强调了在设计中要对钢筋混凝土套管进行校核、验算,在施工过程中要做好测量、纠偏校正和地面沉降监测工作,为今后管道建设中的手掘式顶管穿越提供了一定理论基础和相关经验。
Abstract:
In this paper, the key points of the design and construction of hand-driven pipe jacking were ex-plained and specified. It was emphasized that the reinforced concrete casings should be calculated and verified in the design. During the construction process, the surveying, rectifying and correction and land subsidence monitoring should be emphasized in construction. It provides a theoretical basis and experiences for the hand driven jacking and penetration in the future pipeline constructions.
参考文献
|
[1]
|
李小明. 浅谈市政管道顶管施工中的顶进偏差问题[J]. 中国科技博览, 2009(25): 321-322.
|
|
[2]
|
刘会. 手掘式顶管在市政排水工程中的应用[J]. 探矿工程(岩土钻掘工程), 2008, 35(10): 52-54.
|
|
[3]
|
混凝土和钢筋混凝土排水管. GB/T 11836—2009[S]. 北京: 中国标准出版社, 2009.
|
|
[4]
|
公路工程技术标准. JTG B01—2014[S]. 北京: 人民交通出版社, 2014.
|
|
[5]
|
公路钢筋混凝土及预应力混凝土桥涵设计规范. JTG D62—2012[S]. 北京: 人民交通出版社, 2012.
|