连续高温天气下架空线路动态载流能力评估与运行温度安全告警
Dynamic Ampacity Evaluation and Operating Temperature Safety Warning of Overhead Lines under Continuous High Temperature Weather Conditions
摘要: 近年来重庆地区多次出现夏季连续极端高温天气,空调电负荷大,而高温天气下线路载流能力下降,因此需要关注架空线路的运行安全问题。本文提出以动态载流量和运行温度共同表征架空线路的安全裕度,结合运行气象环境在线辨识架空线路的实时运行温度和动态载流能力,当载流裕度不足或导线温升越限时,向电网调度人员发出安全告警。此外,在预想的供电断面N−1潮流转移后,预测导线温升响应时间,提醒电网调度人员在此时限以内及时采取负荷转供措施。最后,以重庆地区某供电断面为算例,验证了所提方法的有效性和准确性。评估结果可以在确保安全的前提下,充分利用线路动态载流能力,为连续高温天气下的电网运行调度提供指导。
Abstract: In recent years, Chongqing has undergone a series of extreme continuous high temperature weather in summer. The power load of air conditioning increases largely, while the ampacity of overhead lines decreases under extreme high temperature. Therefore, it is important to focus on the operation safety of overhead lines. In this paper, the safety margin of overhead lines is char-acterized by dynamic heat rating and operating temperature, and the real time operating temper-ature and dynamic thermal rating of overhead lines is estimated using operational meteorological environment parameters. And it can send dispatchers a safety alarm when the ampacity margin is not enough or the conductor temperature rise is off-limit. Furthermore, the temperature rise re-sponse time of the conductor is predicted after the preconceived N−1 power flow transferred, to remind power dispatchers to take load transfer measures within this time limit. Finally, the validity of proposed method is verified through a case analysis which considering a power flow section in Chongqing region. And the result of reliability evaluation which takes full advantage of the dynamic heat rating of the line under the premise of ensuring safety can provide reference for operation and dispatching in continuous high temperature weather conditions.
文章引用:丁尧, 熊小伏, 陈强. 连续高温天气下架空线路动态载流能力评估与运行温度安全告警[J]. 智能电网, 2018, 8(5): 419-431. https://doi.org/10.12677/SG.2018.85046

参考文献

[1] 重庆市气象局. 2016年夏季重庆市气候影响评价[EB/OL].
http://183.230.183.17:8090/cqgf_portal/, 2018-08-16.
[2] 国网重庆市电力公司. 重庆高温: 电网负荷连日创下历史新高[EB/OL].
http://www.cq.sgcc.com.cn/html/main/col8/2017-08/24/20170824093846037709709_1.html, 2017-08-24.
[3] Adapa, R. and Douglass, D.A. (2006) Dynamic Thermal Ratings: Monitors and Calculation Methods. 2005 IEEE Power Engineering Society Inaugural Conference and Exposition in Africa, Durban, 11-15 July 2005, 163-167.
[4] Holbert, K.E. and Heydt, G.T. (2001) Prospects for Dynamic Transmission Circuit Ratings. The 2001 IEEE International Symposium on Circuits and Systems, Sydney, 6-9 May 2001, 205-208
[5] Roberts, D., Taylor, P. and Michiorri, A. (2008) Dynamic Thermal Rating for Increasing Network Capacity and Delaying Network Rein-forcements. CIRED Seminar 2008: SmartGrids for Distribution, Frankfurt, 23-24 June 2008, 1-4.
[6] Foss, S.D., Lin, S.H. and Fernandes, R.A. (1983) Dynamic Thermal Line Ratings; Part I: Dynamic Ampacity Rating Algorithm. IEEE Transactions on Power Apparatus & Systems, 3, 1858-1864. [Google Scholar] [CrossRef
[7] 钱之银. 输电线路实时动态增容的可行性研究[J]. 华东电力, 2005, 33(7): 1-4.
[8] 张启平, 钱之银. 输电线路实时动态增容监测系统的可行性研究[C]//中国科学技术协会. 中国科学技术协会2005年学术年会11分会场暨中国电机工程学会2005年学术年会论文集. 北京: 中国科学技术协会, 2005.
[9] 任丽佳, 盛戈嗥, 李力学, 等. 动态确定输电线路输送容量[J]. 电力系统自动化, 2006, 30(17): 45-49.
[10] Xu, B., Ulbig, A. and Andersson, G. (2013) Impacts of Dynamic Line Rating on Power Dispatch Perfor-mance and Grid Integration of Renewable Energy Sources. IEEE PES ISGT Europe 2013, Lyngby, 6-9 October 2013, 1-5.
[11] Kim, S.D. and Morcos, M.M. (2013) An Application of Dynamic Thermal Line Rating Control System to Up-Rate the Ampacity of Overhead Transmission Lines. IEEE Transactions on Power Delivery, 28, 1231-1232. [Google Scholar] [CrossRef
[12] Yang, Y., Harley, R.G., Divan, D., et al. (2009) MLPN based Parameter Estimation to Evaluate Overhead Power Line Dynamic Thermal Rating. 2009 15th International Conference on Intelligent System Applications to Power Systems, Curitiba, 8-12 November 2009, 1-7.
[13] 杨帆, 刘浩军, 王少华, 等. 考虑实时气候对于输电线路载流量的影响[J]. 广东电力, 2017, 30(7): 70-75.
[14] 熊小伏, 尹国涛. 输电线载流能力在线简化评估方法[J]. 华东电力, 2011(8): 1244-1248.
[15] 重庆气象局. 重庆市气象灾害年鉴2006-2010[M]. 重庆: 气象出版社, 2013: 1, 4, 21, 38, 53.
[16] 程炳岩, 孙卫国, 郭渠. 重庆地区夏季高温的气候特征与环流形势分析[J]. 西南大学学报(自然科学版), 2010, 32(1): 73-80.
[17] 郭渠, 孙卫国, 程炳岩, 等. 重庆夏季极端最高气温的时空变化特征分析[J]. 西南大学学报(自然科学版), 2009, 31(5): 98-105.
[18] (2012) Guide for Application of Direct Real-Time Monitoring Systems.
[19] 熊小伏. 电气设备主动保护与控制概念及功能架构[J]. 电力系统自动化, 2018(2): 1-10.
[20] GB/T1179-2017圆线同心绞架空导线[S]. 北京: 中国标准出版社, 2017.
[21] PE/T&D—Transmission and Distribution (2012) IEEE Standard for Calculating the Current-Temperature Relationship of Bare Overhead Conductors. IEEE, New York.