DV-5直流电弧光谱仪测定钽中钼分析应用
Analysis and Application of DV-5 DC Arc Spectrometer for Determination of Molybdenum in Tantalum
DOI: 10.12677/AAC.2020.102009, PDF,   
作者: 刘百利*, 张仁惠, 张佳迪:宁夏东方钽业股份有限公司,宁夏 石嘴山;西北稀有金属特种材料国家重点实验室,宁夏 石嘴山;国家钽铌特种金属材料工程技术研究中心,宁夏 石嘴山
关键词: DV-5直流电弧光谱仪DV-5 DC Arc Spectrometer Ta Mo
摘要: 将纯钽及纯钽制品完全转化成氧化物,按一定比例与载体混合,直流电弧阳极激发,梯光栅和棱镜色散系统进行分光,选择特征谱线由检测器进行信号接收,由计算机进行数据转换和处理。用直流电弧光谱法测定钽中钼元素,方法线性范围5~440 μg/g,并建立了作业指导流程,该法可完全满足生产过程分析工作的快速和准确度需求。
Abstract: The pure tantalum and pure tantalum products are converted into oxides completely, and it was mixed with the carrier material in a certain proportion, and stimulated by the DC anode arc. The split light is developed by using the ladder grating and the prism dispersion system. The selected spectral line is received by the detector, and the data are converted and processed by a computer. The DC arc spectroscopy was used to determine the molybdenum element in tantalum, and the linear range of the method was 5 - 440 μg/g, and an operation instruction was established, this method can fully meet the needs of speed and accuracy during the production process analysis.
文章引用:刘百利, 张仁惠, 张佳迪. DV-5直流电弧光谱仪测定钽中钼分析应用[J]. 分析化学进展, 2020, 10(2): 59-63. https://doi.org/10.12677/AAC.2020.102009

参考文献

[1] 张仁惠. 直流电弧发射光谱法测定铌及铌合金中钽含量[J]. 材料开发与应用, 2017, 32(6):17-21.
[2] 伏军胜, 张仁惠, 李继宏. 直流电弧光谱法测定纯铌及铌制品中砷铋铅锑锡[J]. 冶金分析, 2015, 35(8): 66-70.
[3] 张永龙, 李亚琴, 王小平. 直流电弧原子发射光谱法测定铌及铌合金中镉含量[J]. 材料开发与应用, 2018, 33(4): 39-42.
[4] 王飞. Prodigy DC ARC 直流电弧光谱仪——固体材料及高纯金属分析的最佳选择[C]//北京理化分析测试技术学会2010年北京光谱学术年会. 北京: 北京理化分析测试技术学会, 2010: 20-21.
[5] 李继宏, 张俊峰, 张国军. Prodigy DC Arc直流电弧光谱仪在铌中铪元素分析中的应用[J]. 材料开发与应用, 2015, 30(3): 81-83.