摘要: 基于荧光寿命的光纤测温技术关键点在于将荧光信号中的直流分量与噪声信号等背景干扰去除,尽可能准确地求得荧光寿命τ,但在高精度测量时,运用传统的单指数模型算法,如最小二乘拟合、积分面积比、FFT拟合等方法处理多指数的荧光信号时,求取荧光寿命 会带来很大误差。将LM算法和Prony算法引入荧光测温中,通过仿真分析可知,二者在处理多指数的荧光信号时较传统方法有明显优势,LM算法在低噪条件下,处理双指数模型的最大误差在±10−4 ms之间,响应速度3 × 10−1 s,适合用于高精度测量之中;Prony算法受噪声影响较为明显,在低噪环境下的最大误差为±10−3 ms,响应速度可以达到2 × 10−3 s,适合应用在快速响应条件下。
Abstract: The key point of optical fiber temperature measurement technology based on fluorescence lifetime is to remove the background interference such as the dc component and the noise signal in the fluorescence signal so as to obtain the fluorescence life τ as accurately as possible. However, in the case of high-precision measurement, when the traditional single exponential model algorithms, such as the least squares fitting, the integral area ratio, the FFT fitting and other methods are used to process the multi-exponential fluorescence signal, the fluorescence life error obtained will be large. LM algorithm and Prony algorithm are introduced into fluorescence temperature measurement. Through simulation analysis, it can be seen that the two algorithms have obvious advantages over the traditional methods in processing multi-exponential fluorescence signals. Under low noise condition, the maximum error of LM algorithm is between ±10−4 ms, and the re-sponse speed is 3 × 10−1 s. It is very suitable for high-precision measurement. Prony algorithm is significantly affected by noise. The maximum error is ±10−3 ms in the low noise environment, and the response speed can reach 2 × 10−3 s. It is suitable for application in the case of fast response.
文章引用:贾丹平, 王博强, 刘婉莹, 赵立民. 荧光寿命测温多指数数据处理方法[J]. 传感器技术与应用, 2020, 8(3): 71-79. https://doi.org/10.12677/JSTA.2020.83008

参考文献

[1] 崔凤英, 李莉. 微波场的温度测量[J]. 计量技术, 2003(3): 18-19.
[2] 赵舫, 唐忠, 崔昊杨. 基于荧光光纤测温的电气设备在线监测系统[J]. 电测与仪表, 2015, 52(4): 85-89.
[3] 张月芳, 叶林华, 裘燕青. 掺杂型荧光光纤温度传感技术[J]. 海南大学学报(自然科学版), 2004, 22(3): 226-230.
[4] Jia, D., Zhao, L., Cui, S., et al. (2002) Optical Fiber Fluores-cent Thermometry for Electromagnetically Induced Heating in Medicine Treatment. 4916, 95-97. [Google Scholar] [CrossRef
[5] 伞宏力. 微波消解的温度在线检测系统研究[D]: [硕士学位论文]. 沈阳: 沈阳工业大学, 2005.
[6] 贾丹平, 高浠萌, 王大力. 基于薄膜电阻的新型光纤电流传感器的研究[J]. 仪表技术与传感器, 2016(6): 8-10.
[7] 伞宏力, 贾丹平, 潘晓苏, 等. 用于微波消解仪的荧光光纤测温系统的研制[J]. 沈阳工业大学学报, 2006, 28(6): 639-642.
[8] 贾丹平, 王岩. 基于荧光寿命的微波场中温度测量技术[J]. 仪表技术与传感器, 2018(4): 90-94+97.
[9] 贾丹平. 荧光光纤温度测量技术及应用[M]. 北京: 科学出版社, 2015.
[10] 刘洋, 周燕, 刘育梁. 一种基于列文伯格-马克夸特的高精度荧光寿命计算成像方法[J]. 激光与光电子学进展, 2015, 52(10): 158-162.