西安思源学院分布式供暖的热能耗比较研究
Comparison Study of Thermal Energy Consumption in Distributed Heating at Xi'an Siyuan University
摘要: 西安思源学院经历了燃煤集中供暖–燃气集中供暖–燃气分布式供暖三个时期,从总吨位为42蒸吨的4座燃煤供热锅炉房(负责27万m
2建筑的供暖、学生老师洗浴用热水的供给任务)逐步改造到燃气锅炉房33个,换热站5座,非冷凝型燃气供热锅炉53台,淘汰传统集中供暖,创新为各楼宇独立供暖–分布式供暖。根据多年收集的热能耗数据分析得出:燃气分布式供暖比燃气集中供暖节能,燃气集中供暖比燃煤集中供暖节能。将最节能的燃气分布式供暖所耗热值定为100%,燃气集中供暖所耗的热值则为130.7%,燃煤集中供暖所耗的热值则为191.8%。
Abstract:
Xi’an Siyuan University experienced three periods from coal central heating to gas central heating, until gas distributed heating. In the coal central heating period, there were total 4 coal-burning boiler stations with capacity of 42 tons of steam tonnage, and was responsible for both heating of 270000 m2 building, and showing of students and teachers. In the gas distributed period, there are now total 33 gas boiler rooms, 5 heat exchange stations, 53 sets of non-condensing gas heating boil-er. Eliminate traditional central heating and innovate independent heating for each build-ing-distributed. According to the analysis of thermal energy consumption data collected over the years, the gas distributed heating is more energy saving than the gas central heating, and the gas central heating is more energy saving than the coal central heating. If the heat value of the most energy-efficient system—gas distributed heating is set as 100%, the gas central heating is 130.7%, and the coal central heating is 191.8%.
参考文献
|
[1]
|
冉春雨, 周晓亮, 王春清. 采用量调节分区分时供暖应用研究[J]. 吉林建筑工程学院学报, 2009, 26(1): 75-78.
|
|
[2]
|
赵建会, 张刘刚, 符新燕. 公共建筑分时分温供暖节能研究及效益分析[J]. 西安科技大学学报, 2010, 30(3): 336-340.
|
|
[3]
|
邵宗义, 马长明, 韦梓春. 公共建筑分时分区控制的能耗模拟分析[J]. 建筑热能通风空调, 2015, 34(2): 75-77.
|
|
[4]
|
陈希习. 应用节能技术改造供暖系统[J]. 节能技术, 2001, 19(1): 40-41.
|
|
[5]
|
王翀. 分时分区供暖控制系统的应用[J]. 石油石化节能, 2015(5): 28-29.
|
|
[6]
|
杨中华. 分区供暖控制系统研究[J]. 科学技术创新, 2019(36): 113-114.
|
|
[7]
|
申思, 丁心安, 朱文秀. 高校建筑分时分区供热节能改造经济性自动评价模型[J]. 自动化与仪器仪表, 2021(7): 13-16.
|
|
[8]
|
杨猛, 王英杰. 基于某校区燃煤锅炉替代项目分时分区供热能耗的研究[J]. 工程建设与设计, 2020(15): 43-46.
|
|
[9]
|
穆连波, 张春蕾, 王炳南, 等. 供热系统分时分区控制节能实测分析[J]. 暖通空调, 2013, 43(6): 109-112.
|
|
[10]
|
刘婷婷, 邹艳, 田娟荣, 等. 高校建筑分时分区供暖的节能率及节费率评估[J]. 四川建筑科学研究, 2015, 41(1): 292-294+299.
|