预留人工晶体度数的选择在白内障手术中的研究进展
Research Progress in the Selection of Reserved IOL in Cataract Surgery
摘要: 白内障的摘除结合人工晶体植入是目前治愈白内障的唯一手术方法。由于白内障手术朝着屈光手术的发展趋势,病人不但需要再看的见,也同时对视力有了更高的需求,而影响术后视力改善的首要原因便是对人工晶体度数的选择。人工晶体度数的计算主要是通过眼球生物测量的数据结合人工晶体度数计算公式的选择,而眼球生物测量的准确性是白内障手术后视力提高,保证视觉质量的关键因素。白内障手术的眼球生物测量主要包括眼轴长度、角膜曲率、前房深度等。本文就这几个方面的测量方法、进展及优缺点进行综述。
Abstract: At present, cataract extraction combined with IOL implantation is the only surgical method to cure cataract. Due to the development trend of cataract surgery toward refractive surgery, patients not only need to see again, but also have a higher demand for vision, and the primary reason affecting postoperative vision improvement is the choice of IOL degree. Intraocular lens power calculation is mainly through the measured data of eyeball creature in combination with the choice of intraocular lens power calculation formula, and biological vision after cataract surgery is to improve the accuracy of measurement, a key factor to ensure the quality of vision. Cataract surgery of eye biological measurement mainly includes the ocular axial length corneal curvature anterior chamber depth, etc. In this paper, the measuring method of these a few respects, the progress and advantages and disadvantages are reviewed.
文章引用:余伟. 预留人工晶体度数的选择在白内障手术中的研究进展[J]. 眼科学, 2022, 11(1): 32-36. https://doi.org/10.12677/HJO.2022.111006

参考文献

[1] Matta, S., Park, J., Khanna, R.C., et al. (2016) Cataract Surgery Visual Outcomes and Associated Risk Factors in Secondary Level Eye Care Centers of LV Prasad Eye Institute, India. PLoS ONE, 11, e0144853.
[Google Scholar] [CrossRef] [PubMed]
[2] Olsen, T. (1992) Sources of Error in Intraocular Lens Power Calculation. Journal of Cataract & Refractive Surgery, 18, 125-129.
[Google Scholar] [CrossRef
[3] Mehdizadeh, M. (2008) Effect of Axial Length and Keratometry Measurement Error on Intraocular Lens Implant Power Prediction Formulas in Pediatric Patient. Journal of American Association for Pediatric Ophthalmology and Strabismus, 12, 425-426.
[Google Scholar] [CrossRef] [PubMed]
[4] 郭海科, 金海鹰, 张洪洋. 角膜屈光手术后人工晶状体屈光力的计算[J]. 眼科研究, 2009, 27(1): 144-148.
[5] Jin, H., Holzer, M.P., Rabsilber, T., Borkenstein, A.F., Limberger, I.L., Guo, H., et al. (2010) Intraocular Lens Power Calculation after Laser Refractive Surgery: Corrective Algorithm for Corneal Power Estimation. Journal of Cataract & Refractive Surgery, 36, 87-96.
[6] Yu, S.S., Song, H., Tang, X., et al. (2017) Repeatability of Ophtha Top Topography and Comparison with IOL-Master and LenstarLS900 in Cataract Patients. International Journal of Ophthalmology, 10, 1703-1709.
[7] Fercher, A.F. and Roth, E. (1986) Ophthalmic Laser Interferometer. Proceedings of SPIE, 658, 48-51.
[Google Scholar] [CrossRef
[8] 杨青华, 黄一飞. 眼轴长度测量的研究进展[J]. 解放军医学院学报, 2014, 35(5): 505-508.
[9] Buckhurst, P.J., Wolffsohn, J.S., Shah, S., et al. (2009) A New Optical Low Coherence Reflectometry Device for Ocular Biometry in Cataract Patients. British Journal of Ophthalmology, 93, 949-953.
[Google Scholar] [CrossRef] [PubMed]
[10] 徐海燕, 金玉梅, 李辉, 胡伯越, 姜茹欣. IOL-Master与A型超声测量前房深度和眼轴长度比较及其相关性[J]. 协和医学杂志, 2012, 3(2): 200-203.
[11] 杨磊, 王柏川, 郭海科. IOLMaster 500和Lenstar LS900在白内障术前眼轴测量中的应用[J]. 华中科技大学学报(医学版), 2012, 41(3): 367-369.
[12] 李建昌, 黄振平. 人工晶体度数测量的研究现状[J]. 医学研究生学报, 2009, 22(11): 1211-1216.
[13] Mezer, E., Rootman, D.S. and Abdolell, M. (2004) Early Postoperative Refractive Outcomes of Pediatric Intraocular Lens Implantation. Journal of Cataract and Refractive Surgery, 30, 603-610.
[Google Scholar] [CrossRef] [PubMed]
[14] 宋文晓, 卢广文. 眼球生物测量的应用进展[J]. 临床医学工程, 2011, 18(4): 629-631.
[15] 杨文利, 王宁利. 眼超声诊断学[M]. 北京: 科学技术文献出版社, 2006: 265-298.
[16] Tsang, C.S., Chong, G.S., Yiu, E.P., et al. (2003) Intraocular Lens Power Calculation Formulas in Chinese Eyes with High Axial Myopia. Journal of Cataract & Refractive Surgery, 29, 1358-1364.
[Google Scholar] [CrossRef
[17] Sheng, H., Bottjer, C.A. and Bullimore, M.A. (2004) Ocular Component Measurement Using the Zeiss IOL Master. Optometry and Vision Science, 81, 27-34.
[Google Scholar] [CrossRef] [PubMed]
[18] 刘国军, 沈宝莲, 王海存, 等. 硅油填充眼眼轴的超声测量[J]. 中华超声影像学杂志, 2005, 14(7): 559-560.
[19] 黄锦海, 陈世豪, 温岱宗, 等. Biograph/Lenstar与IOL Master测量眼轴、角膜曲率及前房深度的比较[J]. 中华眼视光学与视觉科学杂志, 2011, 13(2): 126-130.
[20] Shammas, H.J. (2004) Intraocular IOL Power Calculations. SLACK Incorporated, Thorofare, 19.
[21] 吴敏, 叶剑, 孙强, 翟军印, 曹书, 喻箭. 前节OCT与A超测量前房深度的比较[J]. 国际眼科杂志, 2007, 7(5): 1341-1342.
[22] 薛林平, 刘洪, 沈政伟, 尹禾, 姜黎, 马晓玉. Lenstar与A超测量前房深度及晶状体厚度的比较[J]. 临床眼科杂志, 2012, 20(5): 418-420.
[23] 金海鹰, 郭海科, Gerd. U. Auffarth, 张洪洋. Pentacam与IOLMaster对角膜曲率与前房深度测量结果的比较[J]. 眼科新进展, 2010, 30(4): 349-351.
[24] Shen, P., Ding, X., Congdon, N.G., et al. (2012) Comparison of Anterior Ocular Biometry between Optical Low- Coherence Reflectometry and Anterior Segment Optical Coherence Tomography in an Adult Chinese Population. Journal of Cataract & Refractive Surgery, 38, 966-970.
[Google Scholar] [CrossRef] [PubMed]
[25] 柏全豪, 刘珣, 李雪, 阎启昌, 张劲松. IOL-Master生物测量精确性和可重复性研究[J]. 中国实用眼科杂志, 2009, 27(8): 848-852.
[26] Eibschitz-Tsimhoni, M., Tsimhoni, O., Archer, S.M., et al. (2008) Effect of Axial Length and Keratometry Measurement Error on Intraocular Lens Implant Power Prediction Formulas in Pediatric Patients. Journal of AAPOS, 12, 173-176.
[Google Scholar] [CrossRef] [PubMed]
[27] 郭琳, 马波. IOL Master、角膜地形图及Pentacam测量年龄相关性白内障患者角膜散光的比较[J]. 眼科新进展, 2014, 34(9): 868-871.
[28] Kolega, M.Š., Kovačević, S., Čanović, S., Pavičić, A.D. and Bašić, J.K. (2015) Comparison of IOL-Master and Ultrasound Biometry in Preoperative Intra Ocular Lens (IOL) Power Calculation. Collegium Antropologicum, 39, 233-235.
[29] Passi, S.F., Thompson, A.C. and Gupta, P.K. (2018) Comparison of Agreement and Efficiency of a Swept Source- Optical Coherence Tomography Device and an Optical Low-Coherence Reflectometry Device for Biometry Measurements during Cataract Evaluation. Clinical Ophthalmology, 12, 2245-2251.
[Google Scholar] [CrossRef
[30] 沈沛阳, 丁小虎, 何明光, 钟兴武, 陈海波, 邢健强. 光学相干生物测量仪Lenstar LS 900与IOLMaster对眼球生物学参数测量的一致性评价[J]. 眼科新进展, 2014, 34(6): 560-563.