超超临界机组锅炉受热面氧化皮堆积原因分析与防范措施
Cause Analysis and Preventive Measures of Oxide Scale Accumulation on Heating Surface of Ultra Supercritical Unit Boiler
DOI: 10.12677/APP.2022.128055, PDF,   
作者: 杜继臻*, 周 权, 庞凯杰:国能神皖安庆发电有限责任公司,安徽 安庆;张华德, 高 杰, 刘立鹏:苏州热工研究院有限公司,江苏 苏州
关键词: 超超临界机组氧化皮堆积TP347H低温再热器Ultra Supercritical Unit Oxide Scale Accumulation TP347H Low Temperature Reheater
摘要: 火力发电厂炉管氧化皮脱落堆积引起的管子堵塞,是目前超超临界机组锅炉爆管的主要原因。参考某电厂运行约45,000小时的1000 MW超超临界机组氧化皮堆积检测结果,发现使用TP347H的低温再热器管氧化皮堆积尤其严重。根据炉管氧化皮形成和脱落的原理,建议对炉管进行酸洗,并在后期的运行中选择合适的运行温度,减小氧化皮的生成速率,避免氧化皮脱落堆积造成堵管。
Abstract: At present, the main reason for the tube explosion of ultra supercritical unit boilers is the tube blockage caused by the falling off and accumulation of oxide skin of boiler tubes in thermal power plants. Referring to the test results of oxide scale accumulation of 1000MW Ultra Supercritical Units operating for about 45000 hours in a power plant, it is found that the oxide scale accumulation of low temperature reheater tubes using TP347H is particularly serious. According to the principle of the formation and falling off of the oxide skin of the furnace tube, it is recommended to pickle the furnace tube and select the appropriate operating temperature in the later operation to reduce the generation rate of the oxide skin and avoid the pipe blockage caused by the falling off and accumulation of the oxide skin.
文章引用:杜继臻, 张华德, 高杰, 周权, 庞凯杰, 刘立鹏. 超超临界机组锅炉受热面氧化皮堆积原因分析与防范措施[J]. 应用物理, 2022, 12(8): 475-482. https://doi.org/10.12677/APP.2022.128055

参考文献

[1] 杨发亮, 孙彩珍. 超临界锅炉氧化皮脱落原因的分析及控制[J]. 电力学报, 2021, 36(4): 371-377.
[2] 张小霓, 吴文龙, 常亮. 火力发电机组过热器/再热器氧化皮剥落问题分析与预防[J]. 材料保护, 2020, 53(9): 133-136+151.
[3] 刘川槐, 潘卫国, 纪冬梅. 国产TP347HFG奥氏体不锈钢氧化皮问题分析及预控措施[J]. 上海电力大学学报, 2022, 38(1): 61-65.