高级氧化技术在氯苯类污染地块修复治理中的应用——以某有机污染场地小试为例
Application of Advanced Oxidation Technology in the Remediation and Treatment of Chlorobenzene-Contaminated Plots—A Case Study of an Organic Contaminated Site
DOI: 10.12677/HJSS.2023.112006, PDF,   
作者: 杜 欢:安徽国祯环境修复股份有限公司,安徽 合肥
关键词: 氯苯类污染原位化学氧化臭氧–过氧化氢Chlorobenzene Pollution In-Situ Chemical Oxidation Ozone-Hydrogen Peroxide
摘要: 原位高级氧化技术在国内有机污染场地修复中应用广泛,结合某污染场地实际污染情况、水文地质条件,通过现场原位高压注射臭氧–过氧化氢两类氧化药剂的试验,结合连续监测数据,确定臭氧–过氧化氢高级氧化技术可真实有效去除地下水中的1-氯-4-(三氟甲基)-苯、2,5-二氯三氟甲苯、3,4-二氯三氟甲苯,注药5 d后水体中污染物去除率达90%以上。停止注射药剂,土壤中污染物将向地下水中迁移,造成地下水中污染物浓度回升。
Abstract: In-situ advanced oxidation technology has been widely used in the remediation of domestic organic contaminated sites. Combined with the actual pollution situation and hydrogeological conditions of a contaminated site, through the test of in-situ high-pressure injection of ozone-hydrogen peroxide, and the analysis of continuous monitoring data, it was determined that the ozone-hydrogen peroxide could effectively remove 1-chloro-4-(trifluoromethyl)-benzene, 2,5-dichlorotrifluorome- thylbenzene and 3,4-dichlorotrifluoromethylbenzene of groundwater, and the removal rate of pollutants in water was more than 90% after injecting of 5 days. If stopped to inject the chemical agents, the pollutants in the soil would migrate to the groundwater, causing the concentration of pollutants in the groundwater to rise.
文章引用:杜欢. 高级氧化技术在氯苯类污染地块修复治理中的应用——以某有机污染场地小试为例[J]. 土壤科学, 2023, 11(2): 41-47. https://doi.org/10.12677/HJSS.2023.112006

参考文献

[1] 纪录, 张晖. 原位化学氧化法在土壤和地下水修复中的研究进展[J]. 环境工程学报, 2003, 4(6): 37-42.
[2] 林雅洁, 胡婧琳. 有机污染场地化学氧化处置方法综述[J]. 环境工程, 2016, 34(S1): 1003-1007.
[3] 姜林, 樊艳玲, 张丹, 等. 确定空气注射技术影响半径的现场试验: 以北京某焦化厂为例[J]. 中国环境科学, 2012, 32(7): 1216-1222.
[4] 李绍峰, 石冶, 张荣全. 臭氧过氧化氢降解西马津试验研究[J]. 环境科学, 2008, 29(7): 1914-1918.
[5] 王希诚, 高乃云. 臭氧过氧化氢(O3/H2O2)降解2,4,6-三氯酚的多因素影响[J]. 净水技术, 2022, 41(5): 30-35.