立式热交换器分流板压力场数值模拟与结构优化
Numerical Simulation of Pressure Field and Structural Optimizationof Splitter Plate in Vertical Heat Exchanger
DOI: 10.12677/MOS.2023.124309, PDF,    科研立项经费支持
作者: 王默雷, 邓胜祥:上海工程技术大学机械与汽车工程学院,上海;新能源与节能新技术研究所,上海
关键词: 立式热交换器数值模拟分流板压力场Vertical Heat Exchanger Numerical Simulation Shunt Plate Pressure Field
摘要: 针对某工业园区分布式能源系统立式热交换器出口烟温高的问题,因此本文提出在烟气域内增设分流板,改变分流板的高度、夹角、长度,以及对分流板打孔,分析并比较了不同结构的分流板对烟气入口压降的影响,以及不同分流板结构对烟气入口压降的优化效果。得出结果如下:分流板开口位置每向上移动50 mm,入口压降减小,减小幅度为12.7%~8.6%,并呈递减趋势。分流板开口位置每向下移动50 mm,入口压降增大,增大幅度为19.5%~21.4%,并呈上升趋势。当分流板夹角缩小时入口处压降会明显降低,夹角缩小为90˚分流板入口压降变化幅度为58.1%。在分流板上打孔有助于释放压力,但不适合增加分流板直板的长度。
Abstract: Aiming at the problem of high flue gas temperature at the outlet of the vertical heat exchanger of the distributed energy system in an industrial park, this paper proposes to add a splitter plate in the flue gas domain, change the height, angle and length of the splitter plate, and punch the splitter plate to achieve the effect of heat transfer enhancement. The influence of different splitter plates on the pressure drop at the flue gas inlet and the optimization effect of different splitter plate struc-tures on the pressure drop at the flue gas inlet are analyzed and compared. The results are as fol-lows: for every 50 mm upward movement of the opening position of the splitter plate, the inlet pressure drop decreases by 12.7%~8.6%, and shows a decreasing trend. When the opening posi-tion of the splitter plate moves downward by 50 mm, the inlet pressure drop increases by 19.5%~21.4% and shows an upward trend. When the angle of the splitter plate is reduced, the pressure drop at the inlet will be significantly reduced. When the angle is reduced to 90˚, the pres-sure drop at the inlet of the splitter plate changes by 58.1%. The hole channel on the splitter plate helps to release pressure, but is not suitable for increasing the windward area of the splitter plate.
文章引用:王默雷, 邓胜祥. 立式热交换器分流板压力场数值模拟与结构优化[J]. 建模与仿真, 2023, 12(4): 3366-3378. https://doi.org/10.12677/MOS.2023.124309

参考文献

[1] 金红光, 何雅玲, 杨勇平, 等. 分布式能源中的基础科学问题[J]. 中国科学基金, 2020, 34(3): 266-271.
[2] 徐建中. 科学用能与分布式能源系统[J]. 中国能源, 2005, 27(8): 10-13.
[3] 李承周, 王宁玲, 窦潇潇, 杨志平, 王利刚, 杨勇平. 多能源互补分布式能源系统集成研究综述及展望[J/OL]. 中国电机工程学报: 1-25. 2022-09-22.[CrossRef
[4] 杨允. 区域能源多能互补耦合系统在温室中的应用分析[J]. 热能动力工程, 2020, 35(6): 7-14.
[5] 蒋润花, 杨晓西, 杨敏林, 杨小平, 黄斯珉, 陈佰满. 内燃机缸套水低温余热驱动除湿机组实验研究[J]. 工程热物理学报, 2014, 35(12): 2338-2342.
[6] 刘丽芳, 李洪强, 康书硕, 李念平. 主动式热平衡NG-CHP与GSHP耦合分布式系统集成研究[J]. 中国电机工程学报, 2016, 36(12): 3278-3285.
[7] Taler, D. and Ocłoń, P. (2014) Determination of Heat Transfer Formulas for Gas Flow in Fin-and-Tube Heat Exchanger with Oval Tubes Using CFD Simulations. Chemical Engineering and Processing: Process Intensification, 83, 1-11. [Google Scholar] [CrossRef
[8] Taler, D. and Ocłoń, P. (2014) Thermal Contact Resistance in Plate Fin-and-Tube Heat Exchangers, Determined by Experimental Data and CFD Simulations. International Journal of Thermal Sciences, 84, 309-322. [Google Scholar] [CrossRef
[9] Yaïci, W., Ghorab, M. and Entchev, E. (2016) 3D CFD Study of the Effect of Inlet Air Flow Maldistribution on Plate-Fin-Tube Heat Exchanger Design and Thermal-Hydraulic Performance. In-ternational Journal of Heat and Mass Transfer, 101, 527-541. [Google Scholar] [CrossRef
[10] Wu, G.M., Ren, T., Ding, G.L. and Yu, B. (2019) Design and Visualized Validation of a Distributor with Uniform Refrigerant Distribution by Forming Annular Flow. International Journal of Refrigeration, 98, 238-248. [Google Scholar] [CrossRef
[11] Pu, L., Nian, L.Z., Zhang, D.R., et al. (2021) Study of Refrigerant Mal-Distribution and Optimization in Distributor for Air Conditioner. Sustainable Energy Technologies and Assessments, 46, Article ID: 101261. [Google Scholar] [CrossRef
[12] Mohammadi, K. and Malayeri, M.R. (2013) Parametric Study of Gross Flow Maldistribution in a Single-Pass Shell and Tube Heat Exchanger in Turbulent Regime. International Journal of Heat and Fluid Flow, 44, 14-27. [Google Scholar] [CrossRef
[13] Mahvi, A.J. and Garimella, S. (2019) Two-Phase Flow Distri-bution of Saturated Refrigerants in Microchannel Heat Exchanger Headers. International Journal of Refrigeration, 104, 84-94. [Google Scholar] [CrossRef
[14] Wu, G.M., Yan, Z.T., Zhuang, D.W., et al. (2020) Design Method and Application Effects of Embedded-Clapboard Distributor on Refrigerant Distribution among Multi-Tubes of Micro-Channel Heat Exchangers. International Journal of Refrigeration, 119, 420-433. [Google Scholar] [CrossRef
[15] 宋哲, 许波, 陈振乾. 管壳式蒸发器内分流板均分性能的研究[J]. 化工学报, 2021, 72(9): 4629-4638.
[16] Peng, X., Liu, Z.Y., Qiu, C. and Tan, J.R. (2016) Effect of Inlet Flow Maldistribution on the Passage Arrangement Design of Multi-Stream Plate-Fin Heat Exchanger. Applied Thermal Engineering, 103, 67-76. [Google Scholar] [CrossRef
[17] Pal, E., Kumar, I., Joshi, J.B. and Maheshwari, N.K. (2016) CFD Simulations of Shell-Side Flow in a Shell-and-Tube Type Heat Exchanger with and without Baffles. Chemical Engineer-ing Science, 143, 314-340. [Google Scholar] [CrossRef
[18] 文键, 厉彦忠, 周爱民, 张科. 板翅式换热器入口结构内流场的数值模拟[J]. 华中科技大学学报(自然科学版), 2006, 34(7): 5-8.