CBCT X射线图像引导技术在直肠癌IMRT放疗中的应用
Application of CBCT X-Ray Image-Guided Technique in IMRT Radiotherapy for Rectal Cancer
DOI: 10.12677/ACM.2023.13102217, PDF,    国家自然科学基金支持
作者: 刘 平:青岛大学医学部基础医学院,山东 青岛;日照市人民医院放疗科,山东 日照;李玉锋:日照市人民医院放疗科,山东 日照;陈成成:日照市人民医院放射科,山东 日照;赵 涛*:日照市人民医院中心实验室,山东 日照
关键词: 调强放疗锥体束计算机断层扫描X射线图像引导直肠癌Intensity Modulated Radiotherapy Cone Beam Computed Tomography X-Ray Image Guidance Rectal Cancer
摘要: 目的:探讨锥体束计算机断层扫描(CBCT) X射线图像引导技术在直肠癌调强放疗(IMRT)中的作用。方法:回顾性分析2022年1月至2023年6月于日照市人民医院放疗科行IMRT放疗的15例直肠癌患者的临床资料。病人治疗摆位完成后采用CBCT X射线图像引导获得扫描图像,与数字重建放射影像(DRR)进行匹配,得到3个方向的平移摆位误差和3个方向的旋转摆位误差,并进行统计分析,最后得出锥体束计算机断层扫描(CBCT) X射线图像引导技术在直肠癌调强放疗(IMRT)中的作用。结果:15例患者的位置验证均采用CBCT扫描,共获取375组X射线图像,分别与治疗计划DRR进行图像配准然后得出每次治疗的摆位误差。平移方向上Y (头、脚)方向的平移摆位误差最大,摆位误差为(2.245 ± 0.709) cm;X (左、右)方向次之,摆位误差为(0.623 ± 0.203) cm;Z (胸、背)方向最小,摆位误差为(0.492 ± 0.163) cm。旋转方向上RTN (左、右)方向的旋转摆位误差最大,摆位误差为(4.333 ± 1.121)˚;ROLL (胸、背)方向次之,摆位误差为(3.94 ± 0.809)˚;PITCH (头、脚)方向最小,摆位误差为(2.94 ± 1.195)˚。结论:患者治疗前先做CBCT X射线图像引导可观察到摆位误差之大,待修正之后再行放疗可以进一步减小摆位误差,提高放疗的精确度。
Abstract: Objective: To investigate the role of cone beam computed tomography (CBCT) X-ray image-guided technique in intensity-modulated radiotherapy (IMRT) for rectal cancer. Methods: The clinical data of 15 patients with rectal cancer who underwent IMRT radiotherapy in the radiotherapy depart-ment of Rizhao People’s Hospital from January 2022 to June 2023 were retrospectively analyzed. After the patient’s treatment positioning was completed, the CBCT X-ray image guidance was used to obtain the scanning image, which was matched with the digital reconstruction radiography (DRR) to obtain the translation positioning error in three directions and the rotation positioning error in three directions, and statistical analysis was performed. Finally, the role of cone beam computed tomography (CBCT) X-ray image guidance technology in intensity-modulated radiotherapy (IMRT) for rectal cancer was obtained. Results: CBCT scan was used to verify the position of 15 patients. A total of 375 sets of X-ray images were obtained, which were registered with the treatment plan DRR respectively, and then the setup error of each treatment was obtained. In the translation direction, the translation positioning error in the Y (head and foot) direction was the largest, and the posi-tioning error was (2.245 ± 0.709) cm. The X (left and right) direction was the second, and the setup error was (0.623 ± 0.203) cm. The Z (chest and back) direction was the smallest, and the positioning error was (0.492 ± 0.163) cm. In the rotation direction, the rotation positioning error in the RTN (left and right) direction was the largest, and the positioning error is (4.333 ± 1.121) degrees. The ROLL (chest and back) direction was the second, and the setup error was (3.94 ± 0.809) degrees. The direction of PITCH (head and foot) was the smallest, and the positioning error was (2.94 ± 1.195) degrees. Conclusions: CBCT X-ray image guidance before treatment can observe the large setup error. Radiotherapy after correction can further reduce the setup error and improve the ac-curacy of radiotherapy.
文章引用:刘平, 李玉锋, 陈成成, 赵涛. CBCT X射线图像引导技术在直肠癌IMRT放疗中的应用[J]. 临床医学进展, 2023, 13(10): 15864-15869. https://doi.org/10.12677/ACM.2023.13102217

参考文献

[1] 曾铭玥, 冯林春, 丛小虎, 等. 国产与进口精确放疗设备在直肠癌术后放疗中的临床剂量学比较[J]. 解放军医学院学报, 2023, 44(4): 350-353, 358.
[2] 中华医学会肿瘤学分会, 国家卫生健康委员会医政司. 中国结直肠癌诊疗规范(2023版) [J]. 协和医学杂志, 2023, 14(4): 706-733.
[3] 胡腾程, 涂轶, 余晨, 等. 多学科诊疗模式在结直肠癌中的应用价值[J]. 中国肿瘤外科杂志, 2023, 15(3): 256-261.
[4] 常娜, 钱立庭, 赵于飞, 等. 放疗技术在直肠癌术前治疗中的应用与研究进展[J]. 中国肿瘤, 2019, 28(11): 861-868.
[5] 林锋, 曾自力. PDCA循环在降低直肠癌调强放疗摆位误差中的应用研究进展[J]. 现代医药卫生, 2022, 38(5): 791-795.
[6] 李娜娜, 宋斌斌, 李侠, 等. 个性化发泡剂定位在直肠癌放射治疗体位固定中的应用[J]. 肿瘤学杂志, 2023, 29(2): 156-159.
[7] 王宇留, 方涌文, 林晓生, 等. 基于CBCT分析三种体位固定技术在盆腔肿瘤放疗中的应用比较[J]. 现代肿瘤医学, 2023, 31(17): 3237-3242.
[8] 李列, 刘霄, 缪炜烈, 等. 新型直肠癌放疗固定装置的设计研究[J]. 中国设备工程, 2022(16): 10-12.
[9] 方呈祥, 孙海燕. 盆腔肿瘤放疗的锥形束CT应用分次间、内摆位误差研究[J]. 现代中西医结合杂志, 2014, 23(15): 1685-1686.
[10] 吴哲, 刘可, 明智, 等. Eclipse计划系统NTO对直肠癌调强放疗计划的影响[J]. 中国辐射卫生, 2022, 31(4): 471-476.
[11] 周小琴, 罗佳, 陈川, 等. 3种调强技术在局部晚期直肠癌术前新辅助短程放疗的剂量学比较[J]. 重庆医学, 2023, 52(2): 215-220.
[12] 马翔, 李军, 花威, 等. Ex-acTrac X射线图像引导系统在食管癌调强放疗中摆位误差分析[J]. 中国医疗器械信息, 2022, 28(7): 34-36.
[13] 刘强, 阳覃竹, 冉付荣, 等. 颈胸上段食管癌两种固定方式放疗摆位误差的对比研究[J]. 检验医学与临床, 2016, 13(7): 881-882.
[14] 莫小眯, 肖爱农, 伍海彪, 等. 千伏级锥形束kV-CBCT在鼻咽癌调强放疗摆位误差的研究[J]. 中国辐射卫生, 2016, 25(2): 206-208.
[15] 吴海龙, 胡明宗, 付堂钊, 等. 锥形束CT联合六维床在直肠癌患者术前放疗中对靶区外放边界的影响[J]. 医疗装备, 2023, 36(2): 24-27.