[1]
|
Sanders, M., Servaas, S. and Slagt, C. (2020) Accuracy and Precision of Non-Invasive Cardiac Output Monitoring by Electrical Cardiometry: A Systematic Review and Meta-Analysis. Journal of Clinical Monitoring and Computing, 34, 433-460. [Google Scholar] [CrossRef] [PubMed]
|
|
[2]
|
Hudson, I., Houston, A., Aitchison, T., et al. (1990) Reproducibility of Measurements of Cardiac Output in Newborn Infants by Doppler Ultrasound. Archives of Disease in Childhood, 65, 15-19. [Google Scholar] [CrossRef]
|
|
[3]
|
El-Khuffash, A. and McNamara, P.J. (2017) Hemodynamic Assessment and Monitoring of Premature Infants. Clinics in Perinatology, 44, 377-393. [Google Scholar] [CrossRef] [PubMed]
|
|
[4]
|
Grollmuss, O. and Gonzalez, P. (2014) Non-Invasive Cardiac Out-put Measurement in Low and Very Low Birth Weight Infants: A Method Comparison. Frontiers in Pediatrics, 2, 16. [Google Scholar] [CrossRef] [PubMed]
|
|
[5]
|
Schwarz, C.E., Livingstone, V., O’Toole, J.M., et al. (2022) Agreement of Cardiac Output Estimates between Electrical Cardiometry and Transthoracic Echocardiography in Very Preterm Infants. Neonatology, 119, 594-601. [Google Scholar] [CrossRef] [PubMed]
|
|
[6]
|
Hassan, M.A., Bryant, M.B. and Hummler, H.D. (2022) Comparison of Cardiac Output Measurement by Electrical Velocimetry with Echocardiography in Extremely Low Birth Weight Neonates. Neonatology, 119, 18-25. [Google Scholar] [CrossRef] [PubMed]
|
|
[7]
|
洪文超, 龚小慧, 裘刚, 等. 不同胎龄及出生体重新生儿无创超声心输出量参数值测定[J]. 中华新生儿科杂志, 2021, 36(6): 8-11.
|
|
[8]
|
江蓓, 向文, 宋艳, 等. 无创心输出量检测在新生儿中的应用[J]. 中国医药科学, 2019, 9(14): 51-53.
|
|
[9]
|
张丽娟, 林慧宁, 范齐波, 万胜明, 米雪. 电子心力测量法无创心输出量监测在新生儿重症监护室中的应用[J]. 中国妇幼保健, 2021, 36(7): 1675-1677.
|
|
[10]
|
中华医学会急诊医学分会, 北京医学教育协会急诊医学专科分会. 生物电阻抗法无创血流动力学监测在急危重症应用的急诊专家共识[J]. 中华急诊医学杂志, 2023, 32(9): 1163-1171.
|
|
[11]
|
Keren, H., Burkhoff, D. and Squara, P. (2007) Evaluation of a Noninvasive Continuous Cardiac Output Monitoring System Based on Thoracic Bioreactance. American Journal of Physiology-Heart and Circulatory Physiology, 293, H583-H589. [Google Scholar] [CrossRef] [PubMed]
|
|
[12]
|
Squara, P., Denjean, D., Estagnasie, P., et al. (2007) Noninva-sive Cardiac Output Monitoring (NICOM): A Clinical Validation. Intensive Care Medicine, 33, 1191-1194. [Google Scholar] [CrossRef] [PubMed]
|
|
[13]
|
Pinsky, M.R. (2002) Recent Advances in the Clinical Application of Heart-Lung Interactions. Current Opinion in Critical Care, 8, 26-31. [Google Scholar] [CrossRef] [PubMed]
|
|
[14]
|
Bernstein, D.P. and Lemmens, H.J. (2005) Stroke Volume Equation for Impedance Cardiography. Medical & Biological Engineering & Computing, 43, 443-450. [Google Scholar] [CrossRef]
|
|
[15]
|
Ma, M., Noori, S., Maarek, J.M., et al. (2015) Prone Positioning De-creases Cardiac Output and Increases Systemic Vascular Resistance in Neonates. Journal of Perinatology, 35, 424-427. [Google Scholar] [CrossRef] [PubMed]
|
|
[16]
|
Wu, T.W., Lien, R.I., Seri, I. and Noori, S. (2017) Changes in Cardiac Output and Cerebral Oxygenation during Prone and Supine Sleep Positioning in Healthy Term Infants. Archives of Dis-ease in Childhood, Fetal and Neonatal Edition, 102, F483-F489. [Google Scholar] [CrossRef] [PubMed]
|
|
[17]
|
Paviotti, G., Todero, S. and Demarini, S. (2017) Cardiac Output Decreases and Systemic Vascular Resistance Increases in Newborns Placed in the Left-Lateral Position. Journal of Perinatology, 37, 563-565. [Google Scholar] [CrossRef] [PubMed]
|
|
[18]
|
Hsu, K.H., Wu, T.W., Wu, I.H., et al. (2017) Electrical Cardiometry to Monitor Cardiac Output in Preterm Infants with Patent Ductus Arteriosus: A Comparison with Echocardiography. Neo-natology, 112, 231-237. [Google Scholar] [CrossRef] [PubMed]
|
|
[19]
|
O’Neill, R., Dempsey, E.M., Garvey, A.A., et al. (2020) Non-Invasive Cardiac Output Monitoring in Neonates. Frontiers in Pediatrics, 8, Article ID: 614585. [Google Scholar] [CrossRef] [PubMed]
|