危重患者中无创颅内压监测技术及体位相关性进展
Progress in Non-Invasive Intracranial Pressure Monitoring Technology and Positional Correlation in Critically Ill Patients
DOI: 10.12677/acm.2024.1472072, PDF,   
作者: 王启宇:缙云县人民医院重症医学科,浙江 丽水;郑 霞*:浙江大学附属第一医院重症医学科,浙江 杭州
关键词: 颅内压无创监测Intracranial Pressure Non Invasive Monitoring
摘要: 颅内压(ICP)监测对于反应颅脑病情变化极其重要。目前的金标准仍是侵入性的颅内压测量,但由于有创操作容易出现各种并发症,并且有创监测受到患者病情,环境及体位等相关因素而无法进行普遍的应用。故此非侵入性的ICP监测手段应运而生,受到大家的关注。目前在临床中应用的非侵入性ICP测量方法主要包括通过影像、眼科、超声、电生理及其他方法来侧面反映颅内压。本文旨在对当前临床上应用相对广泛的几种非侵入性检测ICP方法,介绍其原理、适应症及部分检测手段在体位改变时所产生的相应变化。虽然这些方法并不能完全替代侵入性监测方法,但在某些特定患者及环境中,可以发挥其特殊作用。
Abstract: Intracranial pressure (ICP) monitoring is extremely important for reflecting changes in the condition of the brain. The current gold standard is still invasive intracranial pressure measurement, but due to the susceptibility of invasive procedures to various complications and the limitations of invasive monitoring due to factors such as patient condition, environment, and position, it cannot be widely applied. Therefore, non-invasive ICP monitoring methods have emerged and received widespread attention. The non-invasive ICP measurement methods currently used in clinical practice mainly include imaging, ophthalmology, ultrasound, electrophysiology, and other methods to indirectly reflect intracranial pressure. This article aims to introduce the principles, indications, and corresponding changes of some non-invasive detection methods for ICP that are currently widely used in clinical practice when there is a change in posture. Although these methods cannot completely replace invasive monitoring methods, they can play a special role in certain specific patients and environments.
文章引用:王启宇, 郑霞. 危重患者中无创颅内压监测技术及体位相关性进展[J]. 临床医学进展, 2024, 14(7): 718-726. https://doi.org/10.12677/acm.2024.1472072

参考文献

[1] Hawryluk, G.W.J., Citerio, G., Hutchinson, P., Kolias, A., Meyfroidt, G., Robba, C., Stocchetti, N. and Chesnut, R. (2022) Intracranial Pressure: Current Perspectives on Physiology and Monitoring. Intensive Care Medicine, 48, 1471-1481. [Google Scholar] [CrossRef] [PubMed]
[2] Bothwell, S.W., Janigro, D. and Patabendige, A. (2019) Cerebrospinal Fluid Dynamics and Intracranial Pressure Elevation in Neurological Diseases. Fluids and Barriers of the CNS, 16, Article No. 9. [Google Scholar] [CrossRef] [PubMed]
[3] Chesnut, R.M., Temkin, N., Carney, N., Dikmen, S., Rondina, C., Videtta, W., Petroni, G., Lujan, S., Pridgeon, J., Barber, J., Machamer, J., Chaddock, K., Celix, J.M., Cherner, M. and Hendrix, T. and Global Neurotrauma Research Group. (2012) A Trial of Intracranial-Pressure Monitoring in Traumatic Brain Injury. The New England Journal of Medicine, 367, 2471-2481. [Google Scholar] [CrossRef
[4] Felix, H. and Oliveira, E.S. (2022) Non-Invasive Intracranial Pressure Monitoring and Its Applicability in Spaceflight. Aerospace Medicine and Human Performance, 93, 517-531. [Google Scholar] [CrossRef
[5] Palasz, J., D’Antona, L., Farrell, S., Elborady, M.A., Watkins, L.D. and Toma, A.K. (2022) External Ventricular Drain Management in Subarachnoid Haemorrhage: A Systematic Review and Meta-Analysis. Neurosurgical Review, 45, 365-373. [Google Scholar] [CrossRef] [PubMed]
[6] Hua, Y., Voorhees, A.P. and Sigal, I.A. (2018) Cerebrospinal Fluid Pressure: Revisiting Factors Influencing Optic Nerve Head Biomechanics. Investigative Ophthalmology & Visual Science, 59, 154-165. [Google Scholar] [CrossRef] [PubMed]
[7] Bekar, A., Doğan, S., Abaş, F., Caner, B., Korfali, G., Kocaeli, H., Yilmazlar, S. and Korfali, E. (2009) Risk Factors and Complications of Intracranial Pressure Monitoring with a Fiberoptic Device. Journal of Clinical Neuroscience, 16, 236-240. [Google Scholar] [CrossRef] [PubMed]
[8] Beer, R., Lackner, P., Pfausler, B. and Schmutzhard, E. (2008) Nosocomial Ventriculitis and Meningitis in Neurocritical Care Patients. Journal of Neurology, 255, 1617-1624. [Google Scholar] [CrossRef] [PubMed]
[9] Padayachy, L.C. (2016) Non-Invasive Intracranial Pressure Assessment. Child’s Nervous System, 32, 1587-1597. [Google Scholar] [CrossRef] [PubMed]
[10] Zhang, X., Medow, J.E., Iskandar, B.J., Wang, F., Shokoueinejad, M., Koueik, J. and Webster, J.G. (2017) Invasive and Noninvasive Means of Measuring Intracranial Pressure: A Review. Physiological Measurement, 38, R143-R182. [Google Scholar] [CrossRef] [PubMed]
[11] Stevens, R.R.F., Gommer, E.D., Aries, M.J.H., Ertl, M., Mess, W.H., Huberts, W. and Delhaas, T. (2021) Optic Nerve Sheath Diameter Assessment by Neurosonology: A Review of Methodologic Discrepancies. Journal of Neuroimaging, 31, 814-825. [Google Scholar] [CrossRef] [PubMed]
[12] Li, J. and Wan, C. (2021) Non-Invasive Detection of Intracranial Pressure Related to the Optic Nerve. Quantitative Imaging in Medicine and Surgery, 11, 2823-2836. [Google Scholar] [CrossRef] [PubMed]
[13] Hanafi, M.G., Verki, M.M. and Parei, S.N. (2019) Ultrasonic Assessment of Optic Nerve Sheath to Detect Increased Intracranial Pressure. Journal of Medical Ultrasound, 27, 69-74. [Google Scholar] [CrossRef
[14] Bayramov, T., Kilicaslan, B., Akinci, S.B. and Boyraz, G. (2022) The Effect of Pneumoperitoneum and Trendelenburg Position on Optic Nerve Sheath Diameter in Patients Undergoing Laparoscopic Hysterectomy. Journal of Obstetrics and Gynaecology Research, 48, 830-837. [Google Scholar] [CrossRef] [PubMed]
[15] Urbonas, M., Raskauskiene, N., Deltuva, V. and Bunevicius, A. (2022) Quantitative Evans Index Estimation Using Ultrasonographic Measurement of the Optic Nerve Sheath Diameter in Supine and Upright Position. Acta Neurochirurgica, 164, 1755-1764. [Google Scholar] [CrossRef] [PubMed]
[16] Demir, U., Taşkın, Ö., Yılmaz, A., Soylu, V.G. and Doğanay, Z. (2023) Does Prolonged Prone Position Affect Intracranial Pressure? Prospective Observational Study Employing Optic Nerve Sheath Diameter Measurements. BMC Anesthesiology, 23, Article No. 79. [Google Scholar] [CrossRef] [PubMed]
[17] Yu, J., Hong, J.H., Park, J.Y., Hwang, J.H., Cho, S.S. and Kim, Y.K. (2018) Propofol Attenuates the Increase of Sonographic Optic Nerve Sheath Diameter during Robot-Assisted Laparoscopic Prostatectomy: A Randomized Clinical Trial. BMC Anesthesiology, 18, Article No. 72. [Google Scholar] [CrossRef] [PubMed]
[18] Kim, M.S., Bai, S.J., Lee, J.R., Choi, Y.D., Kim, Y.J. and Choi, S.H. (2014) Increase in Intracranial Pressure during Carbon Dioxide Pneumoperitoneum with Steep Trendelenburg Positioning Proven by Ultrasonographic Measurement of Optic Nerve Sheath Diameter. Journal of Endourology, 28, 801-806. [Google Scholar] [CrossRef] [PubMed]
[19] Zoerle., T., Caccioppola., A., D’Angelo., E., et al. (2020) Optic Nerve Sheath Diameter Is Not Related to Intracranial Pressure in Subarachnoid Hemorrhage Patients. Neurocritical Care, 33, 491-498. [Google Scholar] [CrossRef] [PubMed]
[20] Rothman, M.I. and Zoarski, G.H. (2003) The Orbit. In: Sutton, D., Ed., Textbook of Radiology and Imaging, Churchill Livingstone, 1573-1595.
[21] Robba, C., Santori, G., Czosnyka, M., Corradi, F., Bragazzi, N., Padayachy, L., Taccone, F.S. and Citerio, G. (2018) Optic Nerve Sheath Diameter Measured Sonographically as Non-Invasive Estimator of Intracranial Pressure: A Systematic Review and Meta-Analysis. Intensive Care Medicine, 44, 1284-1294. [Google Scholar] [CrossRef] [PubMed]
[22] Rajajee, V., Vanaman, M., Fletcher, J.J. and Jacobs, T.L. (2011) Optic Nerve Ultrasound for the Detection of Raised Intracranial Pressure. Neurocritical Care, 15, 506-515. [Google Scholar] [CrossRef] [PubMed]
[23] Benhur, A., Sharma, J., Karna, S.T., Shrivastava, A., Saigal, S. and Waindeskar, V.V. (2022) Analysis of Dynamic Changes in Optic Nerve Sheath Diameter (ONSD) with Ultrasound in Post-Craniotomy Patients: Trends and Correlation with Computed Tomography ONSD and Glasgow Coma Scale in Post-Operative Period. Journal of Neurosciences in Rural Practice, 13, 676-683. [Google Scholar] [CrossRef
[24] Kirk, T., Jones, K., Miller, S. and Corbett, J. (2011) Measurement of Intraocular and Intracranial Pressure: Is There a Relationship? Annals of Neurology, 70, 323-326. [Google Scholar] [CrossRef] [PubMed]
[25] Han, Y., McCulley, T.J. and Horton, J.C. (2008) No Correlation between Intraocular Pressure and Intracranial Pressure. Annals of Neurology, 64, 221-224. [Google Scholar] [CrossRef] [PubMed]
[26] Li, Z., Yang, Y., Lu, Y., Liu, D., Xu, E., Jia, J., Yang, D., Zhang, X., Yang, H., Ma, D. and Wang, N. (2012) Intraocular Pressure vs Intracranial Pressure in Disease Conditions: A Prospective Cohort Study (Beijing ICOP Study). BMC Neurology, 12, Article No. 66. [Google Scholar] [CrossRef] [PubMed]
[27] Golan, S., Kurtz, S., Mezad-Koursh, D., Waisbourd, M., Kesler, A. and Halpern, P. (2013) Poor Correlation between Intracranial Pressure and Intraocular Pressure by Hand-Held Tonometry. Clinical Ophthalmology, 7, 1083-1087. [Google Scholar] [CrossRef
[28] De Bernardo, M., Pilone, V., Di Paola, I., Cione, F., Cembalo, G., Calabrese, P. and Rosa, N. (2023) Intraocular Pressure Variations in Postural Changes: Comparison Between Obese and Non-Obese Controls. Journal of Clinical Medicine, 12, Article 5883. [Google Scholar] [CrossRef] [PubMed]
[29] Geloneck, M.M., Crowell, E.L., Wilson, E.B., Synder, B.E., Chuang, A.Z., Baker, L.A., Bell, N.P. and Feldman, R.M. (2015) Correlation between Intraocular Pressure and Body Mass Index in the Seated and Supine Positions. Journal of Glaucoma, 24, 130-134. [Google Scholar] [CrossRef] [PubMed]
[30] Sheeran, P., Bland, J.M. and Hall, G.M. (2000) Intraocular Pressure Changes and Alterations in Intracranial Pressure. The Lancet, 355, 899.
[31] Aaslid, R., Markwalder, T.M. and Nornes, H. (1982) Noninvasive Transcranial Doppler Ultrasound Recording of Flow Velocity in Basal Cerebral Arteries. Journal of Neurosurgery, 57, 769-774. [Google Scholar] [CrossRef] [PubMed]
[32] Wiegand, C. and Richards, P. (2007) Measurement of Intracranial Pressure in Children: A Critical Review of Current Methods. Developmental Medicine & Child Neurology, 49, 935-941. [Google Scholar] [CrossRef] [PubMed]
[33] Morgalla, M.H. and Magunia, H. (2016) Noninvasive Measurement of Intracranial Pressure via the Pulsatility Index on Transcranial Doppler Sonography: Is Improvement Possible? Journal of Clinical Ultrasound, 44, 40-45. [Google Scholar] [CrossRef] [PubMed]
[34] Kaloria, N., Panda, N.B., Bhagat, H., Kaloria, N., Soni, S.L., Chauhan, R., Chhabra, R. and Jangra, K. (2020) Pulsatility Index Reflects Intracranial Pressure Better Than Resistive Index in Patients with Clinical Features of Intracranial Hypertension. Journal of Neurosciences in Rural Practice, 11, 144-150. [Google Scholar] [CrossRef] [PubMed]
[35] Lucinskas, P., Deimantavicius, M., Bartusis, L., Zakelis, R., Misiulis, E., Dziugys, A. and Hamarat, Y. (2021) Human Ophthalmic Artery as a Sensor for Non-Invasive Intracranial Pressure Monitoring: Numerical Modeling and in Vivo Pilot Study. Scientific Reports, 11, Article No. 4736. [Google Scholar] [CrossRef] [PubMed]
[36] Bellner, J., Romner, B., Reinstrup, P., Kristiansson, K.A., Ryding, E. and Brandt, L. (2004) Transcranial Doppler Sonography Pulsatility Index (PI) Reflects Intracranial Pressure (ICP). Surgical Neurology, 62, 45-51. [Google Scholar] [CrossRef] [PubMed]
[37] Colier, W.N., Van Haaren, N.J. and Oeseburg, B. (1995) A Comparative Study of Two Near Infrared Spectrophotometers for the Assessment of Cerebral Haemodynamics. Acta Anaesthesiologica Scandinavica Supplementum, 107, 101-105. [Google Scholar] [CrossRef] [PubMed]
[38] Chesnut, R., Aguilera, S., Buki, A., Bulger, E., Citerio, G., et al. (2020) A Management Algorithm for Adult Patients with Both Brain Oxygen and Intracranial Pressure Monitoring: The Seattle International Severe Traumatic Brain Injury Consensus Conference (SIBICC). Intensive Care Medicine, 46, 919-929. [Google Scholar] [CrossRef] [PubMed]
[39] Ngwenya, L.B., Burke, J.F. and Manley, G.T. (2016) Brain Tissue Oxygen Monitoring and the Intersection of Brain and Lung: A Comprehensive Review. Respiratory Care, 61, 1232-1244. [Google Scholar] [CrossRef] [PubMed]
[40] Bernard, F., Barsan, W., Diaz-Arrastia, R., Merck, L.H., Yeatts, S. and Shutter, L.A. (2022) Brain Oxygen Optimization in Severe Traumatic Brain Injury (BOOST-3): A Multicentre, Randomised, Blinded-Endpoint, Comparative Effectiveness Study of Brain Tissue Oxygen and Intracranial Pressure Monitoring versus Intracranial Pressure Alone. BMJ Open, 12, E060188. [Google Scholar] [CrossRef] [PubMed]
[41] Fukada, T., Tsuchiya, Y., Iwakiri, H., Ozaki, M. and Nomura, M. (2021) Forehead Regional Oxygen Saturation (RSO2)-Related Ear-Level Arterial Pressure and Lower Thigh RSO2 in the Steep Trendelenburg Position with CO2 Pneumoperitoneum and the Beach Chair Position. Cureus, 13, E15687. [Google Scholar] [CrossRef] [PubMed]
[42] Megjhani, M., Weiss, M., Ford, J., Terilli, K., Kastenholz, N., Nametz, D., Kwon, S.B., Velazquez, A., Agarwal, S., Roh, D.J., Conzen-Dilger, C., Albanna, W., Veldeman, M., Connolly, Jr., Claassen, J., Aries, M., Schubert, G.A. and Park, S. (2023) Optimal Cerebral Perfusion Pressure and Brain Tissue Oxygen in Aneurysmal Subarachnoid Hemorrhage. Stroke, 54, 189-197. [Google Scholar] [CrossRef
[43] Burnol, L., Payen, J.F., Francony, G., Skaare, K., Manet, R., Morel, J., Bosson, J.L. and Gergele, L. (2021) Impact of Head-of-Bed Posture on Brain Oxygenation in Patients with Acute Brain Injury: A Prospective Cohort Study. Neurocritical Care, 35, 662-668. [Google Scholar] [CrossRef] [PubMed]
[44] York, D.H., Pulliam, M.W., Rosenfeld, J.G. and Watts, C. (1981) Relationship between Visual Evoked Potentials and Intracranial Pressure. Journal of Neurosurgery, 55, 909-916. [Google Scholar] [CrossRef] [PubMed]
[45] Zhao, Y.L., Zhou, J.Y. and Zhu, G.H. (2005) Clinical Experience with the Noninvasive ICP Monitoring System. Acta Neurochirurgica Supplement, 95, 351-355. [Google Scholar] [CrossRef
[46] Vieira, M.A., Cavalcanti, M.A., Costa, D.L., Eulálio, K.D., Vale, O.C., Vieira, C.P. and Costa, C.H. (2015) Visual Evoked Potentials Show Strong Positive Association with Intracranial Pressure in Patients with Cryptococcal Meningitis. Arquivos de Neuro-Psiquiatria, 73, 309-313. [Google Scholar] [CrossRef
[47] Friedman, D.I. and Jacobson, D.M. (2004) Idiopathic Intracranial Hypertension. Journal of Neuro-Ophthalmology, 24, 138-145. [Google Scholar] [CrossRef] [PubMed]
[48] Jiang, J., Sari, H., Goldman, R., Huff, E., Hanna, A., Samraj, R., Gourabathini, H. and Bhalala, U. (2023) Neurological Pupillary Index (NPi) Measurement Using Pupillometry and Outcomes in Critically Ill Children. Cureus, 15, E46480. [Google Scholar] [CrossRef] [PubMed]
[49] Stutzman, S., Iype, P., Marshall, J., Speir, K., Schneider, N., Tran, C., Laird, S., Aiyagari, V. and Olson, D. (2022) Inter-Device Reliability of the NPi-200 and NPi-300 Pupillometers. Journal of Clinical Neuroscience, 100, 180-183. [Google Scholar] [CrossRef] [PubMed]
[50] Chen, J.W., Gombart, Z.J., Rogers, S., Gardiner, S.K., Cecil, S. and Bullock, R.M. (2011) Pupillary Reactivity as an Early Indicator of Increased Intracranial Pressure: The Introduction of the Neurological Pupil Index. Surgical Neurology International, 2, Article 82. [Google Scholar] [CrossRef] [PubMed]
[51] Kristiansson, H., Nissborg, E., Bartek, Jr., Andresen, M., Reinstrup, P. and Romner, B. (2013) Measuring Elevated Intracranial Pressure through Noninvasive Methods: A Review of the Literature. Journal of Neurosurgical Anesthesiology, 25, 372-385. [Google Scholar] [CrossRef
[52] Moss, H.E. (2021) Retinal Vein Changes as a Biomarker to Guide Diagnosis and Management of Elevated Intracranial Pressure. Frontiers in Neurology, 12, Article 751370. [Google Scholar] [CrossRef] [PubMed]
[53] D’Antona, L., McHugh, J.A., Ricciardi, F., Thorne, L.W., Matharu, M.S., Watkins, L.D., Toma, A.K. and Bremner, F.D. (2019) Association of Intracranial Pressure and Spontaneous Retinal Venous Pulsation. JAMA Neurology, 76, 1502-1505. [Google Scholar] [CrossRef] [PubMed]
[54] Stewart, P.S., Jensen, O.E. and Foss, A.J. (2014) A Theoretical Model to Allow Prediction of the CSF Pressure from Observations of the Retinal Venous Pulse. Investigative Ophthalmology & Visual Science, 55, 6319-6323. [Google Scholar] [CrossRef] [PubMed]
[55] Georgevsky, D., Gangoda, S.V.S. and Golzan, S.M. (2019) Postural Effects on Spontaneous Retinal Venous Pulsations in Healthy Individuals. Acta Ophthalmologica, 97, E839-E843. [Google Scholar] [CrossRef] [PubMed]
[56] Nag, D.S., Sahu, S., Swain, A. and Kant, S. (2019) Intracranial Pressure Monitoring: Gold Standard and Recent Innovations. World Journal of Clinical Cases, 7, 1535-1553. [Google Scholar] [CrossRef] [PubMed]
[57] Stettin, E., Paulat, K., Schulz, C., Kunz, U. and Mauer, U.M. (2011) Noninvasive Intracranial Pressure Measurement Using Infrasonic Emissions from the Tympanic Membrane. Journal of Clinical Monitoring and Computing, 25, 203-210. [Google Scholar] [CrossRef] [PubMed]
[58] Casselbrant, M., Ingelstedt, S. and Ivarsson, A. (1977) Volume Displacement of the Tympanic Membrane in the Sitting Position as a Function of Middle Ear Muscle Activity. A Quantitative Microflow Method. Acta Oto-Laryngologica, 84, 402-413. [Google Scholar] [CrossRef] [PubMed]
[59] Wagner, N. and Walsted, A. (2000) Postural-Induced Changes in Intracranial Pressure Evaluated Non-Invasively Using The MMS-10 Tympanic Displacement Analyser in Healthy Volunteers. Acta oto-laryngologica. Supplement, 543, 44-47. [Google Scholar] [CrossRef