摘要: 本文中,我们采用试验方法对核级应急柴油发电机组进行抗震鉴定。使用连续白噪声方法,测得机组在三正交轴上的固有频率和阻尼比。根据业主提供的楼板反应谱,生成人工地震波,对机组三正交轴向同时输入模拟地震加速度时程进行激振,分别进行了5次OBE (运行基准地震)和1次SSE (安全停堆地震)地震模拟振动台试验,试验表明机组各项性能指标在抗震试验前后无明显变化,抗震性能满足要求。
Abstract: In this paper, we do the seismic identification of nuclear emergency diesel generator by test method. Dynamic characteristics including orthogonal tri-axial fundamental frequencies and equivalent damping ratios were measured by using the white noise scanning method. Artificial seismic waves were generated according to the floor acceleration response spectrum provided by the owners. Furthermore, five OBE and one SSE shaking table tests for emergency diesel generator were done by using the artificial seismic waves as seismic inputs along the orthogonal tri-axial simultaneity. The results show that the emergency diesel generator satisfies the seismic requirements and there is no obvious change of its performances before and after the earthquake test.
文章引用:季同盛, 王涛, 周根明, 郭霆. 核级应急柴油发电机组抗震试验研究[J]. 声学与振动, 2015, 3(4): 38-45. http://dx.doi.org/10.12677/OJAV.2015.34006

参考文献

[1] GB13625-1992核电厂安全系统电气设备抗震鉴定[S]. 北京: 中国标准出版社, 1993.
[2] 国家核安全局. HAF J0053-1995核设备抗震鉴定试验指南[S]. 北京: 中国标准出版社, 1992.
[3] IEEE Standard 387-1995 (1995) Standard Criteria for Diesel-Generator Units Applied as Standby Power Supplies for Nuclear Power Generating Stations. The Institute of Electrical and Electronic Engineers, Inc., New York.
[4] 刘中华. 核电设备抗震试验与计算分析[D]: [硕士学位论文]. 上海: 上海核工程研究设计院, 2008.
[5] 刘永昌, 等. 核电站用机电设备抗震性能试验鉴定若干问题[J]. 地震工程与工程振动, 1999, 19(3): 68-73.
[6] 汪洋, 等. 1E级应急柴油发电机模拟绕组模拟地震振动台试验研究[J]. 结构工程师, 2013, 29(3): 79-84.