ICL V4c晶体植入术的研究进展
After ICL V4c Implantation in Myopia Patients: A Mini Review
摘要: 近视在全球范围内呈现高发态势,严重影响人们的视觉健康。近视矫正手术不断发展,ICL V4c晶体植入术作为其中重要的一种,在临床应用中备受关注。本文综合多篇文献,对ICL V4c晶体植入术的安全性、对IOL度数计算的影响、视力与视觉质量、术后并发症、影响因素、与其他矫正方式的比较以及未来展望等方面进行综述,旨在全面呈现该手术的研究进展,为临床实践和进一步研究提供参考。
Abstract: Myopia has shown a high prevalence rate globally, severely impacting visual health. With the continuous advancement of myopia correction surgeries, the ICL V4c phakic collame lens implantation has gained significant clinical attention. This article synthesizes multiple literature sources to review the safety of ICL V4c implantation, its impact on collame lens power calculations, visual acuity and quality, postoperative complications, influencing factors, comparisons with other correction methods, and future prospects. The aim is to comprehensively present the research progress of this procedure, providing references for clinical practice and further studies.
文章引用:赵怀兰. ICL V4c晶体植入术的研究进展[J]. 临床医学进展, 2025, 15(11): 2047-2055. https://doi.org/10.12677/acm.2025.15113318

参考文献

[1] Holden, B.A., Fricke, T.R., Wilson, D.A., Jong, M., Naidoo, K.S., Sankaridurg, P., et al. (2016) Global Prevalence of Myopia and High Myopia and Temporal Trends from 2000 through 2050. Ophthalmology, 123, 1036-1042. [Google Scholar] [CrossRef] [PubMed]
[2] Chen, X., Rao, J., Chen, Y., Gao, Y., Huang, R. and Zhou, Q. (2023) Long-Term Observation on Safety and Visual Quality of Implantable Collamer Lens V4c Implantation for Myopia Correction: A 5-Year Follow-Up. International Journal of Ophthalmology, 16, 1123-1129. [Google Scholar] [CrossRef] [PubMed]
[3] Chen, D., Zhao, X., Chou, Y. and Luo, Y. (2022) Comparison of Visual Outcomes and Optical Quality of Femtosecond Laser-Assisted SMILE and Visian Implantable Collamer Lens (ICL V4c) Implantation for Moderate to High Myopia: A Meta-Analysis. Journal of Refractive Surgery, 38, 332-338. [Google Scholar] [CrossRef] [PubMed]
[4] Long, Y., Li, X., Zhou, T., Ye, B., Guo, D. and Shen, Y. (2022) Short-Term Evaluation of Visual Quality, Amplitude of Accommodation, and Stereoacuity between Patients with Moderate-to-High Myopia Who Underwent ICL V4c Implantation and Smile. Journal of Refractive Surgery, 38, 632-640. [Google Scholar] [CrossRef] [PubMed]
[5] Wan, Q., He, P., Wei, R., Ma, K., Yin, H., Tang, J., et al. (2024) Long-Term Observation of V4c Implantable Collamer Lenses Implantation for Moderate to Extreme High Myopia Correction: Five Years Follow-Up. Eye, 38, 1933-1940. [Google Scholar] [CrossRef] [PubMed]
[6] Wei, R., Li, M., Aruma, A., Knorz, M.C., Yang, D., Yu, Y., et al. (2022) Factors Leading to Realignment or Exchange after Implantable Collamer Lens Implantation in 10 258 Eyes. Journal of Cataract & Refractive Surgery, 48, 1190-1196. [Google Scholar] [CrossRef] [PubMed]
[7] Wang, Q., Fan, L. and Zhou, Q. (2023) The Best Choice for Low and Moderate Myopia Patients Incapable for Corneal Refractive Surgery: Implantation of a Posterior Chamber Phakic Intraocular Lens. International Ophthalmology, 43, 575-581. [Google Scholar] [CrossRef] [PubMed]
[8] Niu, L., Miao, H., Han, T., Ding, L., Wang, X. and Zhou, X. (2019) Visual Outcomes of Visian ICL Implantation for High Myopia in Patients with Shallow Anterior Chamber Depth. BMC Ophthalmology, 19, Article No. 121. [Google Scholar] [CrossRef] [PubMed]
[9] Xu, W., Song, Z., Huang, Y., Tao, Y., Wang, J., Wang, L., et al. (2020) Long-Term Outcomes of Retinal Detachment in Phakic Eyes after Implantation of Implantable Collamer Lens V4c for High Myopia Correction. Frontiers in Medicine, 7, Article ID: 582633. [Google Scholar] [CrossRef] [PubMed]
[10] Chen, X., Wang, X., Xu, Y., Cheng, M., Han, T., Wang, X., et al. (2022) Long-Term Comparison of Vault and Complications of Implantable Collamer Lens with and without a Central Hole for High Myopia Correction: 5 Years. Current Eye Research, 47, 540-546. [Google Scholar] [CrossRef] [PubMed]
[11] Cao, W., Zhang, S., Liu, Q., Zhou, J. and Yuan, X. (2023) Changes of Dysfunctional Lens Index before and after Implantable Collamer Lens V4c Implantation in Patients with Moderate-to-High Myopia. International Ophthalmology, 43, 4111-4120. [Google Scholar] [CrossRef] [PubMed]
[12] Wei, R., Li, M., Zhang, H., Aruma, A., Miao, H., Wang, X., et al. (2020) Comparison of Objective and Subjective Visual Quality Early after Implantable Collamer Lens V4c (ICL V4c) and Small Incision Lenticule Extraction (SMILE) for High Myopia Correction. Acta Ophthalmologica, 98, e943-e50. [Google Scholar] [CrossRef] [PubMed]
[13] Xue, L.-F. and He, T.-G. (2023) Research Progress on Position Stability and Visual Quality Changes in the Eye after Implantable Col-Lamer Lens Implantation. International Eye Science, 2, 28-31.
[14] Chen, X., Zhang, D., Liu, Z., Liu, Y., Cai, H., Wu, Q., et al. (2021) Effect of Implantable Collamer Lens on Anterior Segment Measurement and Intraocular Lens Power Calculation Based on Iolmaster 700 and Sirius. Journal of Ophthalmology, 2021, Article ID: 8988479. [Google Scholar] [CrossRef] [PubMed]
[15] Zhu, J., Guo, D., Jin, L., Zhou, T., Shan, S., Zhu, H., et al. (2023) Comparison of Higher-Order Aberrations between Implantable Collamer Lens V4c Implantation and Simulated Spectacle Correction in Patients with High Myopia. Journal Français dOphtalmologie, 46, 630-638. [Google Scholar] [CrossRef] [PubMed]
[16] Zhang, D., Yang, M., Liu, Z., Cai, H., Chen, X. and Zhang, C. (2022) The Effect of Implantable Collamer Lens V4c on Ocular Biometric Measurements and Intraocular Lens Power Calculation Based on Pentacam-Axl and Iolmaster 500. BMC Ophthalmology, 22, Article No. 421. [Google Scholar] [CrossRef] [PubMed]
[17] Salouti, R., Nazarpour-Servak, M., Salouti, K., Ghoreyshi, M. and Nowroozzadeh, M.H. (2024) Comparison of Ocular Biometric Measurements and Intraocular Lens Power Calculation Using Different Methods in Eyes with Implantable Collamer Lenses. Scientific Reports, 14, Article No. 24006. [Google Scholar] [CrossRef] [PubMed]
[18] Xi, W., Yang, M., Wan, J., Wang, Y., Qiao, Y., Huang, X., et al. (2022) Effect of Pupil Dilation on Biometry Measurements and Intraocular Lens Power in Eyes with High Myopia. Frontiers in Medicine, 9, Article ID: 963599. [Google Scholar] [CrossRef] [PubMed]
[19] Fan, R., Chan, T.C., Prakash, G. and Jhanji, V. (2018) Applications of Corneal Topography and Tomography: A Review. Clinical & Experimental Ophthalmology, 46, 133-146. [Google Scholar] [CrossRef] [PubMed]
[20] Aruma, A., Li, M., Choi, J., Miao, H., Wei, R., Yang, D., et al. (2021) Visual Outcomes after Small Incision Lenticule Extraction and Implantable Collamer Lens V4c for Moderate Myopia: 1-Year Results. Graefes Archive for Clinical and Experimental Ophthalmology, 259, 2431-2440. [Google Scholar] [CrossRef] [PubMed]
[21] Huang, L. and Yang, Z. (2022) Application Progress of Smile Surgery and V4c ICL Implantation in the Treatment of High Myopia. Archives of Clinical Psychiatry, 49, 266-270.
[22] Alshamrani, A.A. and Alharbi, S.S. (2019) Phakic Intraocular Lens Implantation for the Correction of Hyperopia. Journal of Cataract and Refractive Surgery, 45, 1503-1511. [Google Scholar] [CrossRef] [PubMed]
[23] Luo, W., Aruma, A., Li, M., Wang, J., Xie, J., Xiao, X., et al. (2023) Four-Year Visual Outcomes and Optical Quality of SMILE and Implantable Collamer Lens V4c (EVO-ICL) Implantation for High Myopia: A Retrospective Study. BMC Ophthalmology, 23, Article No. 341. [Google Scholar] [CrossRef] [PubMed]
[24] Niu, L., Miao, H., Tian, M., Fu, D., Wang, X. and Zhou, X. (2020) One-Year Visual Outcomes and Optical Quality of Femtosecond Laser Small Incision Lenticule Extraction and Visian Implantable Collamer Lens (ICL V4c) Implantation for High Myopia. Acta Ophthalmologica, 98, e662-e667. [Google Scholar] [CrossRef] [PubMed]
[25] Sinha, R., Daga, J., Sahay, P., Gupta, V., Agarwal, T., Sharma, N., et al. (2025) Visual Outcomes with Implantable Collamer Lens versus Small Incision Lenticule Extraction in Moderate-High Myopia: A Pilot Study. Indian Journal of Ophthalmology, 73, 115-121. [Google Scholar] [CrossRef] [PubMed]
[26] Yao, J., Feng, J., Li, W., Liu, C., Li, Y. and Wang, X. (2024) SMILE and ICL Implantation on the Ocular Surface and Meibomian Glands in Patients with Postoperative Myopia. BMC Ophthalmology, 24, Article No. 522. [Google Scholar] [CrossRef] [PubMed]
[27] Zhu, M., Zhu, L., Zhu, Q., Xu, C., Yu, P., Xiao, H., et al. (2020) Clinical Effect and Rotational Stability of TICL in the Treatment of Myopic Astigmatism. Journal of Ophthalmology, 2020, Article ID: 3095302. [Google Scholar] [CrossRef] [PubMed]
[28] Pérez‐Vives, C., Domínguez‐Vicent, A., Madrid‐Costa, D., Ferrer‐Blasco, T. and Montés‐Micó, R. (2013) Myopic Astigmatism Correction: Comparison of a Toric Implantable Collamer Lens and a Bioptics Technique by an Adaptive Optics Visual Simulator. Ophthalmic and Physiological Optics, 33, 114-122. [Google Scholar] [CrossRef] [PubMed]
[29] Bohac, M., Biscevic, A., Gabric, I., Gabric, K., Shijakova, V. and Patel, S. (2022) A Critical Evaluation of Longitudinal Changes of Astigmatism Following Implantation of Toric Implantable Collamer Lens (TICL): A Comparison between Treated and Untreated Cases over 4 Years. Graefes Archive for Clinical and Experimental Ophthalmology, 260, 1377-1386. [Google Scholar] [CrossRef] [PubMed]
[30] Sun, L., Zhang, X., Ding, L., Shen, Y., Qian, Y. and Zhou, X. (2022) Influence of Ocular Residual Astigmatism on the Correction of Myopic Astigmatism by Toric Implantable Collamer Lens: A Comparative Study with Femtosecond Laser Small Incision Lenticule Extraction. Frontiers in Medicine, 9, Article ID: 828492. [Google Scholar] [CrossRef] [PubMed]
[31] Kalra, N., Asif, M.I., Bafna, R.K., Sharma, N. and Sinha, R. (2021) Posterior Chamber Phakic Intraocular Lens Implantation for Refractive Correction in Corneal Ectatic Disorders: A Review. Journal of Refractive Surgery, 37, 351-359. [Google Scholar] [CrossRef] [PubMed]
[32] Jonker, S.R., Berendschot, T.J.M., Saelens, I.Y., Bauer, N.C. and Nuijts, R.M.A. (2020) Phakic Intraocular Lenses: An Overview. Indian Journal of Ophthalmology, 68, 2779-27796. [Google Scholar] [CrossRef] [PubMed]
[33] Gong, D., Deng, S., Dang, K., Yan, Z. and Wang, J. (2024) Causes and Management Strategies for Elevated Intraocular Pressure after Implantable Collamer Lens Implantation. Frontiers in Medicine, 11, Article ID: 1351272. [Google Scholar] [CrossRef] [PubMed]
[34] Raju, N.S.D. (1989) Anterior Chamber Intra Ocular Lens Implantation. Indian Journal of Ophthalmology, 37, 73-74.
[35] Sawada, T., Kimura, W., Kimura, T., Suga, H., Ohte, A., Yamanishi, S., et al. (1998) Long-Term Follow-Up of Primary Anterior Chamber Intraocular Lens Implantation. Journal of Cataract and Refractive Surgery, 24, 1515-1520. [Google Scholar] [CrossRef] [PubMed]
[36] Ning, J., Zhang, Q., Liang, W., Zhang, R., Xing, Z., Jin, L., et al. (2024) Bibliometric and Visualized Analysis of Posterior Chamber Phakic Intraocular Lens Research between 2003 and 2023. Frontiers in Medicine, 11, Article ID: 1391327. [Google Scholar] [CrossRef] [PubMed]
[37] Zhang, H., Gong, R., Zhang, X. and Deng, Y. (2022) Analysis of Perioperative Problems Related to Intraocular Implantable Collamer Lens (ICL) Implantation. International Ophthalmology, 42, 3625-3641. [Google Scholar] [CrossRef] [PubMed]
[38] Packer, M. (2018) The Implantable Collamer Lens with a Central Port: Review of the Literature. Clinical Ophthalmology, 12, 2427-2438. [Google Scholar] [CrossRef] [PubMed]
[39] Fernandes, P., González-Méijome, J.M., Madrid-Costa, D., Ferrer-Blasco, T., Jorge, J. and Montés-Micó, R. (2011) Implantable Collamer Posterior Chamber Intraocular Lenses: A Review of Potential Complications. Journal of Refractive Surgery, 27, 765-776. [Google Scholar] [CrossRef] [PubMed]
[40] Zhang, P., Guo, C., Wang, S., Jiang, W., Wang, D. and Yan, H. (2024) Influencing Factors Comparing Different Vault Groups after Phakic Implantable Collamer Lens Implantation: Review and Meta-Analysis. BMC Ophthalmology, 24, Article No. 70. [Google Scholar] [CrossRef] [PubMed]
[41] Montés-Micó, R., Pastor-Pascual, F., Artiaga-Elordi, E., Ruiz-Mesa, R. and Tañá-Rivero, P. (2021) In Vivo Optical Quality of Posterior-Chamber Phakic Implantable Collamer Lenses with a Central Port. Eye and Vision, 8, Article No. 30. [Google Scholar] [CrossRef] [PubMed]
[42] Wannapanich, T., Kasetsuwan, N. and Reinprayoon, U. (2023) Intraocular Implantable Collamer Lens with a Central Hole Implantation: Safety, Efficacy, and Patient Outcomes. Clinical Ophthalmology, 17, 969-980. [Google Scholar] [CrossRef] [PubMed]
[43] Wang, X. and Zhou, X. (2016) Update on Treating High Myopia with Implantable Collamer Lenses. Asia-Pacific Journal of Ophthalmology, 5, 445-449. [Google Scholar] [CrossRef] [PubMed]
[44] Mimouni, M., Alió del Barrio, J.L. and Alió, J.L. (2020) Occlusion of Aquaport Flow in a Case of Toxic Anterior Segment Syndrome Following Implantable Collamer Lens Surgery Causing Severe Pupillary Block. Journal of Refractive Surgery, 36, 856-859. [Google Scholar] [CrossRef] [PubMed]