基于磁导率锁定放大的高压输电线压接结构内部钢管探测
Internal Steel Pipe Detection in High-Voltage Transmission Line Compression Joints Based on Permeability Locked-In Amplification
DOI: 10.12677/jsta.2026.141009, PDF,    科研立项经费支持
作者: 冯超宇, 王 昊:国网陕西省电力有限公司超高压公司,陕西 西安;李 海*:绍兴杭电集成电路研发有限公司,浙江 绍兴;杭州电子科技大学电子信息学院,浙江 杭州;叶 帆, 袁茂雲, 王晨希:杭州电子科技大学电子信息学院,浙江 杭州
关键词: 高压输电线锁定放大磁导率压接结构无损探伤High-Voltage Transmission Line Locked-In Amplification Permeability Compression Joint Non-Destructive Testing
摘要: 为解决高压输电线压接结构内部钢管检测中X射线法设备笨重、存在辐射的难题,本文提出一种基于磁导率锁定放大的无损检测方法。设计了由硅钢铁芯和激励–检测线圈构成的专用磁导率探头,用于提取内部钢管的磁特性变化;开发了以正交锁定放大为核心的微弱信号处理电路,通过开关解调和低通滤波从强噪声背景中提取信号的正交分量,进而计算幅值与相位。以LGJ-400/35型输电线压接结构为对象的实验表明:该系统噪声低于50 mVpp,能清晰识别钢管位置,定位精度优于10 mm;所研制的便携系统总重仅2.9 kg,较传统X射线设备(通常13~40 kg)大幅减轻。本研究为高压输电线压接质量检测提供了一种轻量化、高精度的有效解决方案,有助于推动线路巡检自动化发展。
Abstract: To address the challenges of heavy equipment and radiation exposure associated with X-ray inspection of internal steel pipes in high-voltage transmission line compression joints, this paper proposes a non-destructive testing method based on permeability locked-in amplification. A specialized permeability probe, consisting of a silicon steel core with excitation and detection coils, was designed to extract magnetic characteristic variations from the internal steel pipe. A weak signal processing circuit, centered on orthogonal lock-in amplification, was developed to extract the quadrature components of the signal from a high-noise background through switching demodulation and low-pass filtering, enabling the calculation of signal amplitude and phase. Experiments conducted on LGJ-400/35 transmission line compression joints demonstrated that the system exhibits noise below 50 mVpp, enables clear identification of the steel pipe location with a positioning accuracy better than 10 mm, and the developed portable system weighs only 2.9 kg, significantly less than traditional X-ray equipment (typically 13~40 kg). This research provides an effective, lightweight, and high-precision solution for quality inspection of high-voltage transmission line compression joints, facilitating the advancement of automated line inspection.
文章引用:冯超宇, 王昊, 李海, 叶帆, 袁茂雲, 王晨希. 基于磁导率锁定放大的高压输电线压接结构内部钢管探测[J]. 传感器技术与应用, 2026, 14(1): 93-100. https://doi.org/10.12677/jsta.2026.141009

参考文献

[1] 戴雨志, 牛雨欣, 张亢. 输电线路断线原因分析及防范措施[J]. 机械与电子控制工程, 2023, 5(9): 101-103.
[2] Zeng, Z., Lv, J., Qu, S. and Shao, H. (2023) Simulation Analysis of Crimping Process of Strain Clamp-ACSR System. 2023 3rd International Conference on Intelligent Power and Systems (ICIPS), Shenzhen, 20-22 October 2023, 245-249. [Google Scholar] [CrossRef
[3] 惠宝军, 傅明利, 刘通, 等. 110 kV及以上电力电缆系统故障统计分析[J]. 南方电网技术, 2017, 11(12): 44-50+67.
[4] 杨梅芳. 基于磁导率检测技术的铁磁试件检测试验研究[D]: [硕士学位论文]. 南昌: 南昌航空大学, 2018.
[5] Levin, A.A., Narykova, M.V., Lihachev, A.I., Kardashev, B.K., Kadomtsev, A.G., Prasolov, N.D., et al. (2022) Comparison of Structural, Microstructural, Elastic, and Microplastic Properties of the AAAC (A50) and ACSR (AC50/8) Cables after Various Operation Periods in Power Transmission Lines. Crystals, 12, Article 1267. [Google Scholar] [CrossRef
[6] Gao, Y., Song, G., Li, S., Zhen, F., Chen, D. and Song, A. (2020) LineSpyX: A Power Line Inspection Robot Based on Digital Radiography. IEEE Robotics and Automation Letters, 5, 4759-4765. [Google Scholar] [CrossRef
[7] Pinto, A.V., Sebrao, M.Z., Lourenco, C.R.S., et al. (2010) Remote Detection of Internal Corrosion in Conductor Cables of Power Transmission Lines. 2010 1st International Conference on Applied Robotics for the Power Industry, Montreal, 5-7 October 2010, 1-6. [Google Scholar] [CrossRef
[8] 程衍伟. 基于ARM的输电线电磁无损检测系统开发[D]: [硕士学位论文]. 南京: 南京航空航天大学, 2016.
[9] Brahim, Y.I., Bellemare, J., Rousseau, G., et al. (2023) Ultrasensitive Lightweight Magnetic Probe for Non-Destructive Inspection of High-Voltage Overhead Lines. NDT & E International, 134, Article ID: 102781. [Google Scholar] [CrossRef
[10] 彭放, 刘甜甜, 苏江文, 等. 基于X射线无损探伤的输电线路耐张线夹缺陷检测[J]. 机械制造与自动化, 2024, 53(4): 264-270.
[11] 王浩洋, 余快, 龚景阳, 等. 输电线路耐张导线金具压接质量检测方法现状与展望[J]. 电气技术, 2023, 24(4): 1-8.
[12] 邱公喆, 康宜华, 程偲, 等. 连续油管分层缺陷磁导率扰动电磁检测方法与检测系统[J]. 焊管, 2023, 46(5): 36-43.
[13] 朱艳生, 高勇, 吕乙松, 等. 微弱信号检测的锁相放大电路仿真[J]. 湖南文理学院学报(自然科学版), 2023, 35(1): 20-25.
[14] 邓明亮. 架空输电线路耐张管压接缺陷分析与质量检查[J]. 湖南电力, 2018, 38(3): 34-37.
[15] 陈家慧, 王方强, 兰贵天, 等. 耐张线夹防滑槽漏压的失效分析与机理研究[J]. 热加工工艺, 2022, 51(12): 146-150+155.
[16] Ou, Z., Shu, Z., He, T., Xu, C., Cen, J. and Han, Z. (2024) A Weak Bias-Magnetized Dynamic Permeability Testing Method for Detecting and Distinguishing Inner and Outer Diameter Defects in Gas Pipelines. NDT & E International, 151, Article ID: 103284. [Google Scholar] [CrossRef
[17] Zhang, Y., Hu, D., Chen, J. and Yin, L. (2023) Research on Non-Destructive Testing of Stress in Ferromagnetic Components Based on Metal Magnetic Memory and the Barkhausen Effect. NDT & E International, 138, Article ID: 102881. [Google Scholar] [CrossRef