定位格架对燃料棒热工水力特性影响的研究
Study on the Influence of Positioning Lattice on Thermal Hydraulic Characteristics of Fuel Rod
DOI: 10.12677/NST.2018.64012, PDF,   
作者: 赖 诚, 白金川, 金 聪, 徐樟楠, 袁 亮:苏州热工研究院有限公司,广东 深圳
关键词: Benchmark试验定位格架临界热流密度Benchmark Test Positioning Lattice Critical Heat Flux
摘要: 根据临界热流密度Benchmark本体试验,研究定位格架间距对临界热流密度大小和发生点以及发生临界通道的热工水力参数的影响。分析结果表明,随着定位格架间距的增大,临界点向下一个定位格架上游移动,临界热流密度增大,发生临界通道的出口质量流速减小。
Abstract: Based on the ontology test of Benchmark, it was studied that how the positioning lattice spacing influenced on the critical heat flux and its occurrence point as well as the thermal hydraulic pa-rameters of the critical passage. The results show that as the distance between the positioning lattice increases, the critical point moves upstream of the next positioning lattice, the critical heat flux increases, and the exit mass velocity of the critical passage decreases.
文章引用:赖诚, 白金川, 金聪, 徐樟楠, 袁亮. 定位格架对燃料棒热工水力特性影响的研究[J]. 核科学与技术, 2018, 6(4): 99-107. https://doi.org/10.12677/NST.2018.64012

参考文献

[1] 张龙根, 何玉枝, 朱炳艺. 压水堆燃料组件定位格架的交混长度[J]. 原子能科学技术, 1982, 16(3): 272.
[2] Rubin, A.J. (2011) OECD/NRC Benchmark Based on NUPEC PWR Subchannel and Bundle Test (PSBT)-Analysis Using Subchannel Code CTF and System Code Trace. Pennsylvania State University, State College.
[3] Jackson, J.W. and Cobra N.E. (1981) IIIc/MIT-2: A Digital Computer Program for Steady State and Transient Thermal-Hydraulic Analysis of Rod Bundle Nuclear Fuel Element. Todreas. Massachusetts Institute of Technology Cambridge, Cambridge.
[4] 张金玲, 郭玉君, 秋穗正, 等. 反应堆临界热流密度的计算[J]. 西安交通大学学报, 1995, 29(5): 118-123.
[5] 于平安, 朱瑞安, 喻真烷, 等. 核反应堆热工分析[M]. 上海: 上海交通大学出版社, 2002.