某香精公司遗留污水应急处理工程案例
Emergency Engineering Example of Wastewater Treatment on Essence Plant
摘要: 某香精公司退役场地废水应急处理项目,污水成分复杂、处理难度大。采用除油沉淀、气浮、芬顿氧化、活性炭组合工艺进行处理。厂内遗留废水在25天内处理完成,运行成本合理,CODcr (mg/L)可由3200降至200以下,达到接收单位进水要求。
Abstract:
The wastewater emergency treatment project of the decommissioning site of a flavor company is complicated and difficult to be treated. The oil removal precipitation + air floatation + fenton oxida-tion + activated carbon were used to treat the wastewater. The residual waste water in the plant can be treated within 25 days, and the operating cost is reasonable. The CODcr (mg/L) can be reduced from 3200 to less than 200 to meet the water inlet requirements of the receiving unit.